Although the five-degree-of-freedom magnetic levitation system composed of two conical bearingless switched reluctance motors(CBSRMs)owns the simplest structure,the torque and levitation forces are coupled greatly.The...Although the five-degree-of-freedom magnetic levitation system composed of two conical bearingless switched reluctance motors(CBSRMs)owns the simplest structure,the torque and levitation forces are coupled greatly.Therefore,it is difficult to make the rotor rotate and be fully levitated simultaneously.To solve this problem,two different role division control strategies are proposed in this paper,i.e.individual role division and mutual role division control strategies.The difference between them is the selection of motor which controls the torque or the axial force.In order to understand the characteristics of control variables,the principle and mathematical model of CBSRM are introduced.After that,two control strategies are explained in detail.To verify the demonstrated performance,the simulations are completed with MATLAB/Simulink.展开更多
In order to improve the frequency response and anti-interference characteristics of the smart electromechanical actuator(EMA)system,and aiming at the force fighting problem when multiple actuators work synchronously,a...In order to improve the frequency response and anti-interference characteristics of the smart electromechanical actuator(EMA)system,and aiming at the force fighting problem when multiple actuators work synchronously,a multi input multi output(MIMO)position difference cross coupling control coordinated strategy based on double‑closed-loop load feedforward control is proposed and designed.In this strategy,the singular value method of return difference matrix is used to design the parameter range that meets the requirements of system stability margin,and the sensitivity function and the H_(∞)norm theory are used to design and determine the optimal solution in the obtained parameter stability region,so that the multi actuator system has excellent synchronization,stability and anti-interference.At the same time,the mathematical model of the integrated smart EMA system is established.According to the requirements of point-to-point control,the controller of double-loop control and load feedforward compensation is determined and designed to improve the frequency response and anti-interference ability of single actuator.Finally,the 270 V high-voltage smart EMA system experimental platform is built,and the frequency response,load feedforward compensation and coordinated control experiments are carried out to verify the correctness of the position difference cross coupling control strategy and the rationality of the parameter design,so that the system can reach the servo control indexes of bandwidth 6 Hz,the maximum output force 20000 N and the synchronization error≤0.1 mm,which effectively solves the problem of force fighting.展开更多
基金supported by the National Natural Science Foundations of China (Nos. 51877107,51577087,51477074)
文摘Although the five-degree-of-freedom magnetic levitation system composed of two conical bearingless switched reluctance motors(CBSRMs)owns the simplest structure,the torque and levitation forces are coupled greatly.Therefore,it is difficult to make the rotor rotate and be fully levitated simultaneously.To solve this problem,two different role division control strategies are proposed in this paper,i.e.individual role division and mutual role division control strategies.The difference between them is the selection of motor which controls the torque or the axial force.In order to understand the characteristics of control variables,the principle and mathematical model of CBSRM are introduced.After that,two control strategies are explained in detail.To verify the demonstrated performance,the simulations are completed with MATLAB/Simulink.
基金supported by the National Natural Science Foundation of China(No.52077100)the Aviation Science Foundation(No.201958052001)
文摘In order to improve the frequency response and anti-interference characteristics of the smart electromechanical actuator(EMA)system,and aiming at the force fighting problem when multiple actuators work synchronously,a multi input multi output(MIMO)position difference cross coupling control coordinated strategy based on double‑closed-loop load feedforward control is proposed and designed.In this strategy,the singular value method of return difference matrix is used to design the parameter range that meets the requirements of system stability margin,and the sensitivity function and the H_(∞)norm theory are used to design and determine the optimal solution in the obtained parameter stability region,so that the multi actuator system has excellent synchronization,stability and anti-interference.At the same time,the mathematical model of the integrated smart EMA system is established.According to the requirements of point-to-point control,the controller of double-loop control and load feedforward compensation is determined and designed to improve the frequency response and anti-interference ability of single actuator.Finally,the 270 V high-voltage smart EMA system experimental platform is built,and the frequency response,load feedforward compensation and coordinated control experiments are carried out to verify the correctness of the position difference cross coupling control strategy and the rationality of the parameter design,so that the system can reach the servo control indexes of bandwidth 6 Hz,the maximum output force 20000 N and the synchronization error≤0.1 mm,which effectively solves the problem of force fighting.