This article presents an approach which employs a commercial Reynolds-Averaged Navier-Stokes(RANS)solver to predict the steady wake field and loading distributions for a rim driven thruster.Four different cases of p...This article presents an approach which employs a commercial Reynolds-Averaged Navier-Stokes(RANS)solver to predict the steady wake field and loading distributions for a rim driven thruster.Four different cases of propeller blades are chosen to be calculated with the presented method.The propeller blade radial circulation and chordwise circulation density distributions are analyzed.The maximum radial circulation is found at the blade tip,which is different from conventional shaft driven propeller.The numerical results indicate that there is no tip leakage vortex in rim driven propulors.But there exist the tip joint vortex and the root region vortex.Bollard characteristics are calculated by taking rim surface effect into account.From the predicted results the second case in this paper is selected as the final one to perform hydrodynamic experiment.The calculation results with empirical rim surface corrections are compared with the measurement.It shows that the developed numerical method can well predict hydrodynamic performances of the rim driven thruster.展开更多
This article presents the design of a new implantable axial-flow blood pump. The special feature of the flow channel inside the blood pump is that the blood is driven by a big-small tandem impeller installed in the in...This article presents the design of a new implantable axial-flow blood pump. The special feature of the flow channel inside the blood pump is that the blood is driven by a big-small tandem impeller installed in the inner hole of the cylinder magnet of a brushless direct current motor. The inner hole makes the main flow channel possible, while the gap between the inner end of the stator and the outer end of the cylinder magnet gives the shape of the tributary flow channel. There is no motor magnet inside the main flow channel, therefore, more blood can pass through it. The gap of the tributary flow channel is very small, but the blood flow in it is not blocked. Thus, the efficiency is increased and the volume and weight of blood pump can be reduced greatly. The outer diameter, length and weight of the manufactured implantable axial-flow blood pump are 29.6 mm, 76 mm and 158 g, respectively. The impeller spins at the speed of 9000 rpm and can generate a pressure head of 100 mmHg and a flow rate of 8 L/rain. In an animal experiment, the blood pump has been successfully applied as a Ventricular Assist Device (VAD) in the chest of a small cow. Besides a mathematical model is established to simulate the flow inside an axial-flow blood pump of implantable VAD. The numerical studies on the performance of the implantable axial-flow blood pump are carried out by combining this mathematical model and the Fluent software. The numerical results agree well with those of experiments, with the maximum error less than 10%.展开更多
Based on established numerical methods and hydrodynamic performance testing facilities,CFD technique are applied to improve the design of the implantable axial flow blood pump and the flow analysis.(1) Applying brus...Based on established numerical methods and hydrodynamic performance testing facilities,CFD technique are applied to improve the design of the implantable axial flow blood pump and the flow analysis.(1) Applying brushless machine magnet steel,reducing its thickness while increasing the length,the flow channel's cross-section is increased,with no space connection between the large and the small rotators,and with a cone transition segment from the bearing to the principal axis,the flow is made smoother.The rotating speed is lowered by 1000 rpm-1200 rpm under the same flow rate and pressure head,and thus the hemolysis can be avoided.(2) Different outlet stator guiding vanes are selected for the same blood pump for analyses of hydrodynamic performances and flow fields.An excellent design not only can regulate the rotating flow field into an axial one,reduce the circulation loss and improve the pump efficiency,but also can avoid backflow,vortex and secondary flow at the pump outlet,and thus the thrombus can be prevented.(3) The calf live tests show that some residual clots exist at the inner wall of the outlet connection bends,which are analyzed and explained by CFD techniques and the corresponding improvements are proposed.All results are verified by hydrodynamic performance tests and PIV flow field tests,and consistent conclusions are obtained.展开更多
文摘This article presents an approach which employs a commercial Reynolds-Averaged Navier-Stokes(RANS)solver to predict the steady wake field and loading distributions for a rim driven thruster.Four different cases of propeller blades are chosen to be calculated with the presented method.The propeller blade radial circulation and chordwise circulation density distributions are analyzed.The maximum radial circulation is found at the blade tip,which is different from conventional shaft driven propeller.The numerical results indicate that there is no tip leakage vortex in rim driven propulors.But there exist the tip joint vortex and the root region vortex.Bollard characteristics are calculated by taking rim surface effect into account.From the predicted results the second case in this paper is selected as the final one to perform hydrodynamic experiment.The calculation results with empirical rim surface corrections are compared with the measurement.It shows that the developed numerical method can well predict hydrodynamic performances of the rim driven thruster.
基金supported by the National High Technology Research and Development program of China (863 Program, Grant No. 2007AA02Z439)The Program for Outstanding Medical Academic Leader of Shanghai
文摘This article presents the design of a new implantable axial-flow blood pump. The special feature of the flow channel inside the blood pump is that the blood is driven by a big-small tandem impeller installed in the inner hole of the cylinder magnet of a brushless direct current motor. The inner hole makes the main flow channel possible, while the gap between the inner end of the stator and the outer end of the cylinder magnet gives the shape of the tributary flow channel. There is no motor magnet inside the main flow channel, therefore, more blood can pass through it. The gap of the tributary flow channel is very small, but the blood flow in it is not blocked. Thus, the efficiency is increased and the volume and weight of blood pump can be reduced greatly. The outer diameter, length and weight of the manufactured implantable axial-flow blood pump are 29.6 mm, 76 mm and 158 g, respectively. The impeller spins at the speed of 9000 rpm and can generate a pressure head of 100 mmHg and a flow rate of 8 L/rain. In an animal experiment, the blood pump has been successfully applied as a Ventricular Assist Device (VAD) in the chest of a small cow. Besides a mathematical model is established to simulate the flow inside an axial-flow blood pump of implantable VAD. The numerical studies on the performance of the implantable axial-flow blood pump are carried out by combining this mathematical model and the Fluent software. The numerical results agree well with those of experiments, with the maximum error less than 10%.
基金supported by the National High Technology Research and Development Program of China (863 Program Grant No. 2007AA02Z439)The Program for Outstanding Medical Academic Leader of Shanghai
文摘Based on established numerical methods and hydrodynamic performance testing facilities,CFD technique are applied to improve the design of the implantable axial flow blood pump and the flow analysis.(1) Applying brushless machine magnet steel,reducing its thickness while increasing the length,the flow channel's cross-section is increased,with no space connection between the large and the small rotators,and with a cone transition segment from the bearing to the principal axis,the flow is made smoother.The rotating speed is lowered by 1000 rpm-1200 rpm under the same flow rate and pressure head,and thus the hemolysis can be avoided.(2) Different outlet stator guiding vanes are selected for the same blood pump for analyses of hydrodynamic performances and flow fields.An excellent design not only can regulate the rotating flow field into an axial one,reduce the circulation loss and improve the pump efficiency,but also can avoid backflow,vortex and secondary flow at the pump outlet,and thus the thrombus can be prevented.(3) The calf live tests show that some residual clots exist at the inner wall of the outlet connection bends,which are analyzed and explained by CFD techniques and the corresponding improvements are proposed.All results are verified by hydrodynamic performance tests and PIV flow field tests,and consistent conclusions are obtained.