As primary separators in pressurized water reactors (PWRs), cyclone separators separate most of the water from vapor-water two-phase mixture, which is important to the safety and economics of nuclear power plants. To ...As primary separators in pressurized water reactors (PWRs), cyclone separators separate most of the water from vapor-water two-phase mixture, which is important to the safety and economics of nuclear power plants. To improve the performance of cyclone separators, we tested new structures in this study, e.g. porosity and inclined angle of the separator wall. Under different structures, separation efficiency and pressure drop were studied theoretically and experimentally. Results show that each of the structural parameters has an effect on separator performance, but none of the trends is monotonically in experimental ranges. Besides separator structures, the comprehensive performance is also determined by flow patterns. From segregated to homogeneous flow, the separation ability decreases. The separation efficiency is about 5% higher at 20° inclined angle when the superficial velocities are 0.012 and 16 m·s-1 for the liquid and gas, respectively. The separation efficiency is only 91% without an impeller, while it is up to 100% at the same superficial velocities of air and water, 16 and 0.015 m·s-1 , respectively. Based on the study, it is promising to understand deeply the separation mechanism and further to provide data for designing large-scaled separators for advanced pressurized water reactors.展开更多
In this paper,we propose a novel probe to identify phases in any two-phase flows where one phase is conductive and the other nonconductive.We can further obtain many parameters such as void fraction,bubble velocity,an...In this paper,we propose a novel probe to identify phases in any two-phase flows where one phase is conductive and the other nonconductive.We can further obtain many parameters such as void fraction,bubble velocity,and interfacial area concentration.Compared with the traditional probe,the novel probe has unique advantages that it is less dependent on water conductance or distance between the electrodes,and that the amplitude is bigger between high and low levels.Theoretical analyses showed that the measurement error became higher when water conductance decreases or distance increases,which is consistent with the theoretical analyses.Experimental results showed that the output signal kept constant with salt content of 0-5% and electrode distance of 0-30 mm in tap water.The level difference was up to 6.4 V,resulting in identifying two phases easily.Time traces of phase identification were completely consistent with the flow structures.展开更多
To identify flow patterns in horizontal gas-liquid flows,a single-wire capacitance probe was used for voltage output for the first time.Regardless of the measurement accuracy of water layer height,the statistic parame...To identify flow patterns in horizontal gas-liquid flows,a single-wire capacitance probe was used for voltage output for the first time.Regardless of the measurement accuracy of water layer height,the statistic parameters of the voltage-time traces were compared within the same sampling time of 5s under different flow patterns,including maximum,minimum,range,and average.The results show that most of flow pattens were accurately identified except for some transition lines.展开更多
基金Supported by National Natural Science Foundation of China (No. 51006068)Science and Technology on Reactor System Design Technology Laboratory,Nuclear Power Institute of China
文摘As primary separators in pressurized water reactors (PWRs), cyclone separators separate most of the water from vapor-water two-phase mixture, which is important to the safety and economics of nuclear power plants. To improve the performance of cyclone separators, we tested new structures in this study, e.g. porosity and inclined angle of the separator wall. Under different structures, separation efficiency and pressure drop were studied theoretically and experimentally. Results show that each of the structural parameters has an effect on separator performance, but none of the trends is monotonically in experimental ranges. Besides separator structures, the comprehensive performance is also determined by flow patterns. From segregated to homogeneous flow, the separation ability decreases. The separation efficiency is about 5% higher at 20° inclined angle when the superficial velocities are 0.012 and 16 m·s-1 for the liquid and gas, respectively. The separation efficiency is only 91% without an impeller, while it is up to 100% at the same superficial velocities of air and water, 16 and 0.015 m·s-1 , respectively. Based on the study, it is promising to understand deeply the separation mechanism and further to provide data for designing large-scaled separators for advanced pressurized water reactors.
基金Support by the National Natural Science Foundation of China (No. 51006068)
文摘In this paper,we propose a novel probe to identify phases in any two-phase flows where one phase is conductive and the other nonconductive.We can further obtain many parameters such as void fraction,bubble velocity,and interfacial area concentration.Compared with the traditional probe,the novel probe has unique advantages that it is less dependent on water conductance or distance between the electrodes,and that the amplitude is bigger between high and low levels.Theoretical analyses showed that the measurement error became higher when water conductance decreases or distance increases,which is consistent with the theoretical analyses.Experimental results showed that the output signal kept constant with salt content of 0-5% and electrode distance of 0-30 mm in tap water.The level difference was up to 6.4 V,resulting in identifying two phases easily.Time traces of phase identification were completely consistent with the flow structures.
基金Supported by Postdoctoral Foundation of P R China(Grant No:20080440619)
文摘To identify flow patterns in horizontal gas-liquid flows,a single-wire capacitance probe was used for voltage output for the first time.Regardless of the measurement accuracy of water layer height,the statistic parameters of the voltage-time traces were compared within the same sampling time of 5s under different flow patterns,including maximum,minimum,range,and average.The results show that most of flow pattens were accurately identified except for some transition lines.