期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Data reduction and calibration of the FMG onboard ASO-S 被引量:8
1
作者 Jiang-Tao Su Xian-Yong Bai +12 位作者 Jie Chen Jing-Jing Guo Suo Liu Xiao-Fan Wang hai-qing xu Xiao Yang Yong-Liang Song Yuan-Yong Deng Kai-Fan Ji Lei Deng Yu Huang Hui Li Wei-Qun Gan 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2019年第11期63-78,共16页
The Full-disk vector Magneto Graph(FMG)instrument will carry out polarization observations at one wavelength position of the Fe I 5324.179?spectral line.This paper describes how to choose this single wavelength positi... The Full-disk vector Magneto Graph(FMG)instrument will carry out polarization observations at one wavelength position of the Fe I 5324.179?spectral line.This paper describes how to choose this single wavelength position,the relevant data-processing and the magnetic field calibrations based on the measured polarization signals at one single wavelength position.It is found that solar radial Doppler velocity,which can cause the spectral line to shift,is a disadvantageous factor for the linear calibration at one wavelength position.Observations at two symmetric wavelength positions may significantly reduce the wavelength shift effect(~75%),but simulations show that such polarization signals located at the solar limbs(e.g.,beyond the longitude range of±30°)are not free from the effect completely.In future work,we plan to apply machine learning techniques to calibrate vector magnetic fields,or employ full Stokes parameter profile inversion techniques to obtain accurate vector magnetic fields,in order to complement the linear calibration at the single wavelength position. 展开更多
关键词 SUN photosphere-Sun MAGNETIC fields-Sun CALIBRATION
下载PDF
Automatic detection and correction algorithms for magnetic saturation in the SMFT/HSOS longitudinal magnetograms
2
作者 徐海清 刘锁 +8 位作者 苏江涛 邓元勇 Andrei Plotnikov 白先勇 陈洁 杨潇 郭晶晶 王晓帆 宋永亮 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第3期158-166,共9页
A longitudinal magnetic field often suffers the saturation effect in a strong magnetic field region when the measurement is performed at a single-wavelength point and linear calibration is adopted.In this study,we dev... A longitudinal magnetic field often suffers the saturation effect in a strong magnetic field region when the measurement is performed at a single-wavelength point and linear calibration is adopted.In this study,we develop a method that can judge the threshold of saturation in Stokes V/I observed by the Solar Magnetic Field Telescope(SMFT)and correct it automatically.The procedure is to first perform the second-order polynomial fit to the Stokes V/I vs.I/I_(m)(I_(m) is the maximum value of Stokes I)curve to estimate the threshold of saturation,then reconstruct Stokes V/I in a strong field region to correct for saturation.The algorithm is demonstrated to be effective by comparing with the magnetograms obtained by the Helioseismic and Magnetic Imager(HMI).The accuracy rate of detection and correction for saturation is~99.4%and~88%respectively among 175 active regions.The advantages and disadvantages of the algorithm are discussed. 展开更多
关键词 Sun:sunspots Sun:magnetic field Methods:data analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部