The Full-disk vector Magneto Graph(FMG)instrument will carry out polarization observations at one wavelength position of the Fe I 5324.179?spectral line.This paper describes how to choose this single wavelength positi...The Full-disk vector Magneto Graph(FMG)instrument will carry out polarization observations at one wavelength position of the Fe I 5324.179?spectral line.This paper describes how to choose this single wavelength position,the relevant data-processing and the magnetic field calibrations based on the measured polarization signals at one single wavelength position.It is found that solar radial Doppler velocity,which can cause the spectral line to shift,is a disadvantageous factor for the linear calibration at one wavelength position.Observations at two symmetric wavelength positions may significantly reduce the wavelength shift effect(~75%),but simulations show that such polarization signals located at the solar limbs(e.g.,beyond the longitude range of±30°)are not free from the effect completely.In future work,we plan to apply machine learning techniques to calibrate vector magnetic fields,or employ full Stokes parameter profile inversion techniques to obtain accurate vector magnetic fields,in order to complement the linear calibration at the single wavelength position.展开更多
A longitudinal magnetic field often suffers the saturation effect in a strong magnetic field region when the measurement is performed at a single-wavelength point and linear calibration is adopted.In this study,we dev...A longitudinal magnetic field often suffers the saturation effect in a strong magnetic field region when the measurement is performed at a single-wavelength point and linear calibration is adopted.In this study,we develop a method that can judge the threshold of saturation in Stokes V/I observed by the Solar Magnetic Field Telescope(SMFT)and correct it automatically.The procedure is to first perform the second-order polynomial fit to the Stokes V/I vs.I/I_(m)(I_(m) is the maximum value of Stokes I)curve to estimate the threshold of saturation,then reconstruct Stokes V/I in a strong field region to correct for saturation.The algorithm is demonstrated to be effective by comparing with the magnetograms obtained by the Helioseismic and Magnetic Imager(HMI).The accuracy rate of detection and correction for saturation is~99.4%and~88%respectively among 175 active regions.The advantages and disadvantages of the algorithm are discussed.展开更多
基金supported by the Strategic Priority Research Program on Space Science, the Chinese Academy of Sciences (Grant Nos. XDA15320302, XDA15052200 and XDA15320102)the National Natural Science Foundation of China (Grant Nos. 11773038, 11703042, U1731241, 11427901, 11427803, 11473039 and U1831107)the 13th Fiveyear Informatization Plan of the Chinese Academy of Sciences (Grant No. XXH13505-04)
文摘The Full-disk vector Magneto Graph(FMG)instrument will carry out polarization observations at one wavelength position of the Fe I 5324.179?spectral line.This paper describes how to choose this single wavelength position,the relevant data-processing and the magnetic field calibrations based on the measured polarization signals at one single wavelength position.It is found that solar radial Doppler velocity,which can cause the spectral line to shift,is a disadvantageous factor for the linear calibration at one wavelength position.Observations at two symmetric wavelength positions may significantly reduce the wavelength shift effect(~75%),but simulations show that such polarization signals located at the solar limbs(e.g.,beyond the longitude range of±30°)are not free from the effect completely.In future work,we plan to apply machine learning techniques to calibrate vector magnetic fields,or employ full Stokes parameter profile inversion techniques to obtain accurate vector magnetic fields,in order to complement the linear calibration at the single wavelength position.
基金supported by the National Natural Science Foundation of China(Grant Nos.11703042,11911530089,U1731241,11773038,11427901,11427803,11673033,U1831107,11873062)the Strategic Priority Research Program on Space Science+1 种基金Chinese Academy of Sciences(Grant Nos.XDA15320302,XDA15052200,XDA15320102)the13th Five-year Informatization Plan of Chinese Academy of Sciences(Grant No.XXH13505–04)。
文摘A longitudinal magnetic field often suffers the saturation effect in a strong magnetic field region when the measurement is performed at a single-wavelength point and linear calibration is adopted.In this study,we develop a method that can judge the threshold of saturation in Stokes V/I observed by the Solar Magnetic Field Telescope(SMFT)and correct it automatically.The procedure is to first perform the second-order polynomial fit to the Stokes V/I vs.I/I_(m)(I_(m) is the maximum value of Stokes I)curve to estimate the threshold of saturation,then reconstruct Stokes V/I in a strong field region to correct for saturation.The algorithm is demonstrated to be effective by comparing with the magnetograms obtained by the Helioseismic and Magnetic Imager(HMI).The accuracy rate of detection and correction for saturation is~99.4%and~88%respectively among 175 active regions.The advantages and disadvantages of the algorithm are discussed.