Development of 3He-filled linear position-sensitive detector for neutron scattering instruments at CSNS
1
作者 Lin Zhu Jian-rong Zhou +21 位作者 Xin-feng Jiang Xiao-juan Zhou Wen-qin Yang Yuan-Guang Xia Liang Xiao Hong Luo Bei-ju Guan Yan-feng Wang Hong Xu Pei-xun Shen hai-yun teng Jia-jie Li Gui-an Yang Ju-ping Xu Huai-can Chen Song-lin Wang Jian Zhuang Jun-rong Zhang Wen Yin Zhi-jia Sun Yuan-bo Chen Tianjiao Liang 《Radiation Detection Technology and Methods》 CSCD 2023年第1期100-106,共7页
Background Helium-3-filled linear position-sensitive detectors(LPSDs)have been widely applied to neutron scattering instruments in recent decades owing to the high detection efficiency,the excellent neutron/gamma disc... Background Helium-3-filled linear position-sensitive detectors(LPSDs)have been widely applied to neutron scattering instruments in recent decades owing to the high detection efficiency,the excellent neutron/gamma discrimination,and the ability to construct the detector with large area coverage.More than 65%of neutron instruments at the China Spallation Neutron Source(CSNS)require ^(3)He LPSDs for the building of the detector system.The detector of a neutron scattering instrument is normally an array detector composed of a large number of ^(3)He LPSDs.However,no appropriate substitute detector is available for the ^(3)He LPSD for operation over a short period,and its specifications need to be customized to satisfy the requirements of different instruments.This necessitates the development of ^(3)He LPSDs with different specifications for building and upgrading the detectors of neutron scattering instruments at CSNS.Purpose To meet the general requirements specified by the neutron instruments at CSNS,a ^(3)He LPSD was developed and its performances were investigated by using the neutron beam.Methods The neutron beam experiments for this ^(3)He LPSD,including measurements of counting rate plateau curve,position calibration,and position resolution along the tube path,were carried out at the beamline-20 of CSNS.To evaluate its performance in the instrument operation,a detector module made of this ^(3)He LPSD has been installed in the multi-physics instrument(MPI),and the comparison test with the commercial ^(3)He LPSD has been conducted at neutron scattering experiments.Results and conclusion The experimental measurements for this ^(3)He LPSD based on the neutron beam showed that it satisfies the requirements for use in neutron scattering instruments.It reaches a plateau slope of 2.6%/100 V with a plateau range from 1750 to 1950 V and attained a minimal position resolution of 5.3 mm(FWHM),superior to the one achieved by the commercial ^(3)He LPSD.In addition,this ^(3)He LPSD detector module applied to the MPI has been working steadily for half of year and is available for use in experiments.These results provide a sound basis for the subsequent construction and upgradation of the detector of neutron scattering instruments at CSNS. 展开更多
关键词 Counting rate CSNS LPSD Plateau curve Position resolution
原文传递
The research of laser-based rapid measurement system for scintillator neutron detectors arrays
2
作者 Bin Tang Qian Yu +7 位作者 Chan Huang hai-yun teng Yan-feng Wang Hong Xu Yun-tao Liu Lin Qiu Guang-you Wei Zhi-jia Sun 《Radiation Detection Technology and Methods》 CSCD 2020年第4期400-406,共7页
Purpose Scintillator Neutron Detectors Arrays(SNDA)were successfully installed at General Purpose Powder Diffractome-ter(GPPD)at the China Spallation Neutron Source(CSNS).The inhomogeneity of the detection efficiency ... Purpose Scintillator Neutron Detectors Arrays(SNDA)were successfully installed at General Purpose Powder Diffractome-ter(GPPD)at the China Spallation Neutron Source(CSNS).The inhomogeneity of the detection efficiency in each detector module,which caused by the gain nonuniformity of the multi-anode photo-multiplier tubes(MA-PMTs)and the inconsistency of the wave-length shifting fibers in collecting scintillation photons,need to be mitigated before the installation.Methods An automated rapid measurement system based on the blue laser and the two-dimensional mobile platform was developed to calibrate the light response of each channel in detector modules.According to the test results of this system,the electronics threshold of each channel of the SNDA is adjusted.Before the installation of the all 40 SNDA modules in GPPD,the electronics thresholds of each channel are adjusted according to the measurement results of this rapid measurement system.Results and Conclusion Compared with the unadjusted detector module,the adjusted one obtained a better uniformity of the neutron detection efficiency.The inhomogeneity of the detection efficiency is improved from 27.4%to 10.9%.The test result of the diffraction peak of the standard sample Si showed that the adjusted SNDA works well in GPPD. 展开更多
关键词 SYSTEM SHIFTING LASER