With the widespread adoption of ultrasound guidance,Seldinger puncture techniques,and intracardiac electrical positioning technology for the placement of peripherally inserted central catheters in recent years,an incr...With the widespread adoption of ultrasound guidance,Seldinger puncture techniques,and intracardiac electrical positioning technology for the placement of peripherally inserted central catheters in recent years,an increasing number of medical staff and patients now accept peripheral placement of totally implantable venous access devices(TIVADs)in the upper arm.This approach has the advantage of completely avoiding the risks of hemothorax,pneumothorax,and neck and chest scarring.Medical specialties presently engaged in this study in China include internal medicine,surgery,anesthesiology,and interventional departments.However,command over implantation techniques,treatment of complications,and proper use and maintenance of TIVAD remain uneven among different medical units.Moreover,currently,there are no established quality control standards for implantation techniques or specifications for handling complications.Thus,this expert consensus is proposed to improve the success rate of TIVAD implantation via the upper-arm approach,reduce complication rates,and ensure patient safety.This consensus elaborates on the technical indications and contraindications,procedures and technical points,treatment of complications,and the use and maintenance of upper-arm TIVAD,thus providing a practical reference for medical staff.展开更多
The widely tunable and high resolution mid-infrared laser based on a BaGa_(4)Se_(7)(BGSe)optical parametric oscillator(OPO)was demonstrated.A wavelength tuning range of 2.76–4.64μm and a wavelength tuning resolution...The widely tunable and high resolution mid-infrared laser based on a BaGa_(4)Se_(7)(BGSe)optical parametric oscillator(OPO)was demonstrated.A wavelength tuning range of 2.76–4.64μm and a wavelength tuning resolution of about 0.3 nm were obtained by a BGSe(56.3°,0°)OPO,which was pumped by a 1064 nm laser.It is the narrowest reported wavelength tuning resolution for BGSe OPO,and was obtained by simultaneously controlling the angle and temperature of BGSe.展开更多
As π-calculus based on the interleaving semantics cannot depict the true concurrency and has few supporting tools,it is translated into Petri nets.π-calculus is divided into basic elements,sequence,concurrency,choic...As π-calculus based on the interleaving semantics cannot depict the true concurrency and has few supporting tools,it is translated into Petri nets.π-calculus is divided into basic elements,sequence,concurrency,choice and recursive modules.These modules are translated into Petri nets to construct a complicated system.Petri nets semantics for π-calculus visualize system structure as well as system behaviors.The structural analysis techniques allow direct qualitative analysis of the system properties on the structure of the nets.Finally,Petri nets semantics for π-calculus are illustrated by applying them to mobile telephone systems.展开更多
文摘With the widespread adoption of ultrasound guidance,Seldinger puncture techniques,and intracardiac electrical positioning technology for the placement of peripherally inserted central catheters in recent years,an increasing number of medical staff and patients now accept peripheral placement of totally implantable venous access devices(TIVADs)in the upper arm.This approach has the advantage of completely avoiding the risks of hemothorax,pneumothorax,and neck and chest scarring.Medical specialties presently engaged in this study in China include internal medicine,surgery,anesthesiology,and interventional departments.However,command over implantation techniques,treatment of complications,and proper use and maintenance of TIVAD remain uneven among different medical units.Moreover,currently,there are no established quality control standards for implantation techniques or specifications for handling complications.Thus,this expert consensus is proposed to improve the success rate of TIVAD implantation via the upper-arm approach,reduce complication rates,and ensure patient safety.This consensus elaborates on the technical indications and contraindications,procedures and technical points,treatment of complications,and the use and maintenance of upper-arm TIVAD,thus providing a practical reference for medical staff.
基金the Director Foundation of State Key Laboratory of Pulsed Power Laser Technology(No.SKL2022ZR03)the Independent Innovation Science Foundation of National University of Defense Technolo-gy(23-ZZCX-JDZ-44)+1 种基金the Young Doctoral Fund of the College of Electronic Engineering,NUDT(No.KY22C211)the Technology Domain Fund of 173 Project(Nos.2021-JCJQ-JJ-0284,and 2022-JCJQ-JJ-0237).
文摘The widely tunable and high resolution mid-infrared laser based on a BaGa_(4)Se_(7)(BGSe)optical parametric oscillator(OPO)was demonstrated.A wavelength tuning range of 2.76–4.64μm and a wavelength tuning resolution of about 0.3 nm were obtained by a BGSe(56.3°,0°)OPO,which was pumped by a 1064 nm laser.It is the narrowest reported wavelength tuning resolution for BGSe OPO,and was obtained by simultaneously controlling the angle and temperature of BGSe.
基金supported by the National Natural Science Foundation of China(U1564205)the Project of Construction of Innovative Teams and Teacher Career Development for Universities and Colleges under Beijing Municipality(IDHT20180508)。
文摘As π-calculus based on the interleaving semantics cannot depict the true concurrency and has few supporting tools,it is translated into Petri nets.π-calculus is divided into basic elements,sequence,concurrency,choice and recursive modules.These modules are translated into Petri nets to construct a complicated system.Petri nets semantics for π-calculus visualize system structure as well as system behaviors.The structural analysis techniques allow direct qualitative analysis of the system properties on the structure of the nets.Finally,Petri nets semantics for π-calculus are illustrated by applying them to mobile telephone systems.