Intramedullary tumors are a class of central nervous system tumors with an incidence of 2 to 4%.As they are located very deep and frequently cause postoperative neurological complications,surgical resection is difficu...Intramedullary tumors are a class of central nervous system tumors with an incidence of 2 to 4%.As they are located very deep and frequently cause postoperative neurological complications,surgical resection is difficult.In recent years,many surgeons have performed electrophysiological monitoring to effectively reduce the occurrence of post-operative neurological complications.Modern electrophysiological monitoring technology has advanced considerably,leading to the development of many monitoring methods,such as SSEPs,MEPs,DCM,and EMG,to monitor intramedullary tumors.However,electrophysiological monitoring in tumor resection is still being studied.In this article,we discussed the different monitoring methods and their role in monitoring intramedullary tumors by reviewing previous studies.Intratumorally tumors need to be monitored for a summary of the condition of the patient.Only by using various monitoring methods flexibly and through clear communication between surgeons and neurophysiological experts can good decisions be made during surgery and positive surgical results be achieved.展开更多
With the critical charge reduced to generate a single event effect (SEE) and high working frequency for a nanometer integrated circuit, the single event effect (SET) becomes increasingly serious for high performan...With the critical charge reduced to generate a single event effect (SEE) and high working frequency for a nanometer integrated circuit, the single event effect (SET) becomes increasingly serious for high performance SOC and DSP chips. To analyze the radiation-hardened method of SET for the nanometer integrated circuit, the n+ guard ring and p+ guard ring have been adopted in the layout for a 65 nm commercial radiation-hardened standard cell library. The weakest driving capacity inverter cell was used to evaluate the single event transient (SET) pulse-width distribution. We employed a dual-lane measurement circuit to get more accurate SET's pulse- width. Six kinds of ions, which provide LETs of 12.5, 22.5, 32.5, 42, 63, and 79.5 MeV-cm2/mg, respectively, have been utilized to irradiate the SET test circuit in the Beijing Tandem Accelerator Nuclear Physics National Laboratory. The testing results reveal that the pulse-width of most SETs is shorter than 400 ps in the range of LETefr from 12.5 MeV.cm2/mg to 79.5 MeV-cm2/mg and the pulse-width presents saturation tendency when the effective linear energy transfer (LETeff value is larger than 40 MeV-cm2/mg. The test results also show that the hardened commercial standard cell's pulse-width concentrates on 33 to 264 ps, which decreases by 40% compared to the pulse-width of the 65 nm commercial unhardened standard cell.展开更多
文摘Intramedullary tumors are a class of central nervous system tumors with an incidence of 2 to 4%.As they are located very deep and frequently cause postoperative neurological complications,surgical resection is difficult.In recent years,many surgeons have performed electrophysiological monitoring to effectively reduce the occurrence of post-operative neurological complications.Modern electrophysiological monitoring technology has advanced considerably,leading to the development of many monitoring methods,such as SSEPs,MEPs,DCM,and EMG,to monitor intramedullary tumors.However,electrophysiological monitoring in tumor resection is still being studied.In this article,we discussed the different monitoring methods and their role in monitoring intramedullary tumors by reviewing previous studies.Intratumorally tumors need to be monitored for a summary of the condition of the patient.Only by using various monitoring methods flexibly and through clear communication between surgeons and neurophysiological experts can good decisions be made during surgery and positive surgical results be achieved.
文摘With the critical charge reduced to generate a single event effect (SEE) and high working frequency for a nanometer integrated circuit, the single event effect (SET) becomes increasingly serious for high performance SOC and DSP chips. To analyze the radiation-hardened method of SET for the nanometer integrated circuit, the n+ guard ring and p+ guard ring have been adopted in the layout for a 65 nm commercial radiation-hardened standard cell library. The weakest driving capacity inverter cell was used to evaluate the single event transient (SET) pulse-width distribution. We employed a dual-lane measurement circuit to get more accurate SET's pulse- width. Six kinds of ions, which provide LETs of 12.5, 22.5, 32.5, 42, 63, and 79.5 MeV-cm2/mg, respectively, have been utilized to irradiate the SET test circuit in the Beijing Tandem Accelerator Nuclear Physics National Laboratory. The testing results reveal that the pulse-width of most SETs is shorter than 400 ps in the range of LETefr from 12.5 MeV.cm2/mg to 79.5 MeV-cm2/mg and the pulse-width presents saturation tendency when the effective linear energy transfer (LETeff value is larger than 40 MeV-cm2/mg. The test results also show that the hardened commercial standard cell's pulse-width concentrates on 33 to 264 ps, which decreases by 40% compared to the pulse-width of the 65 nm commercial unhardened standard cell.