After reconstructing the anterior cruciate ligament(ACL),unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage.With good biological features and high formability,M...After reconstructing the anterior cruciate ligament(ACL),unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage.With good biological features and high formability,Magnesium-Zinc-Gadolinium(ZG21)wires are developed to bunch the tendon graft for matching the bone tunnel during transplantation.Microstructure,tensile strength,degradation,and cytotoxicity of ZG21 wire are evaluated.The rabbit model is used for assessing the biological effects of ZG21 wire by Micro-CT,histology,and mechanical test.The SEM/EDS,immunochemistry,and in vitro assessments are performed to investigate the underlying mechanism.Material tests demonstrate the high formability of ZG21 wire as surgical suture.Micro-CT shows ZG21 wire degradation accelerates tunnel bone formation,and histologically with earlier and more fibrocartilage regeneration at the healing interface.The mechanical test shows higher ultimate load in the ZG21 group.The SEM/EDS presents ZG21 wire degradation triggered calcium phosphate(Ca-P)deposition.IHC results demonstrate upregulation of Wnt3a,BMP2,and VEGF at the early phase and TGFβ3 and Type II collagen at the late phase of healing.In vitro tests also confirmed the Ca-P in the metal extract could elevate the expression of Wnt3a,βcatenin,ocn and opn to stimulate osteogenesis.Ex vivo tests of clinical samples indicated suturing with ZG21 wire did not weaken the ultimate loading of human tendon tissue.In conclusion,the ZG21 wire is feasible for tendon graft bunching.Its degradation products accelerated intra-tunnel endochondral ossification at the early healing stage and therefore enhanced bone-tendon interface healing in ACL reconstruction.展开更多
In this study,perforated cannulated magnesium(Mg)hip stents were fabricated via modified Mg injection molding and conventional machining,respectively.Additionally,the stent canal was filled with paraffin to simulate i...In this study,perforated cannulated magnesium(Mg)hip stents were fabricated via modified Mg injection molding and conventional machining,respectively.Additionally,the stent canal was filled with paraffin to simulate injection of biomaterials.The microstructure,mechanical performance,corrosion behavior,and biocompatibility were comparably studied.Scanning electron microscopy(SEM)and energy dispersive spectroscopy(EDS)showed higher affinity of interstitial element such as oxygen and carbon as consequences of routine molding process.After immersion in SBF,machining stents showed reduced degradation rate and increased deposition of calcium phosphate compared to molding stents.Corrosion resistance was improved via paraffin-filling.Consistently,the hemolysis and in vitro osteoblast cell culture models showed favourable biocompatibility in machining stents compared to molding ones,which was improved by paraffin-filling treatment as well.These results implied that the feasibility of the prepared machining stents as the potential in vivo orthopaedic application where slower degradation is required,which could be enhanced by designing canal-filling injection of biomaterials as well.展开更多
基金Theme-based research scheme of Hong Kong Research Grant Council(RGC Ref:T13-402/17-N)National Natural Science Foundation of China(No.U1804251)。
文摘After reconstructing the anterior cruciate ligament(ACL),unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage.With good biological features and high formability,Magnesium-Zinc-Gadolinium(ZG21)wires are developed to bunch the tendon graft for matching the bone tunnel during transplantation.Microstructure,tensile strength,degradation,and cytotoxicity of ZG21 wire are evaluated.The rabbit model is used for assessing the biological effects of ZG21 wire by Micro-CT,histology,and mechanical test.The SEM/EDS,immunochemistry,and in vitro assessments are performed to investigate the underlying mechanism.Material tests demonstrate the high formability of ZG21 wire as surgical suture.Micro-CT shows ZG21 wire degradation accelerates tunnel bone formation,and histologically with earlier and more fibrocartilage regeneration at the healing interface.The mechanical test shows higher ultimate load in the ZG21 group.The SEM/EDS presents ZG21 wire degradation triggered calcium phosphate(Ca-P)deposition.IHC results demonstrate upregulation of Wnt3a,BMP2,and VEGF at the early phase and TGFβ3 and Type II collagen at the late phase of healing.In vitro tests also confirmed the Ca-P in the metal extract could elevate the expression of Wnt3a,βcatenin,ocn and opn to stimulate osteogenesis.Ex vivo tests of clinical samples indicated suturing with ZG21 wire did not weaken the ultimate loading of human tendon tissue.In conclusion,the ZG21 wire is feasible for tendon graft bunching.Its degradation products accelerated intra-tunnel endochondral ossification at the early healing stage and therefore enhanced bone-tendon interface healing in ACL reconstruction.
基金supported by Theme-based Research Scheme(Ref No.T13-402/17-N)Collaborative Research Fund(C402617W)from the Research Grants Council of the Hong Kong Special Administrative Region,ChinaInnovation and Technology Fund(ITS/208/18FX)from the Innovation and Technology Commission of Hong Kong。
文摘In this study,perforated cannulated magnesium(Mg)hip stents were fabricated via modified Mg injection molding and conventional machining,respectively.Additionally,the stent canal was filled with paraffin to simulate injection of biomaterials.The microstructure,mechanical performance,corrosion behavior,and biocompatibility were comparably studied.Scanning electron microscopy(SEM)and energy dispersive spectroscopy(EDS)showed higher affinity of interstitial element such as oxygen and carbon as consequences of routine molding process.After immersion in SBF,machining stents showed reduced degradation rate and increased deposition of calcium phosphate compared to molding stents.Corrosion resistance was improved via paraffin-filling.Consistently,the hemolysis and in vitro osteoblast cell culture models showed favourable biocompatibility in machining stents compared to molding ones,which was improved by paraffin-filling treatment as well.These results implied that the feasibility of the prepared machining stents as the potential in vivo orthopaedic application where slower degradation is required,which could be enhanced by designing canal-filling injection of biomaterials as well.