期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake 被引量:9
1
作者 Yue-ying PAN Shu-chang ZHOU +4 位作者 Yu-jin WANG Qian LI Ting-ting ZHU Chun-xia LIU han-xiong guan 《Current Medical Science》 SCIE CAS 2020年第1期178-183,共6页
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a... The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction. 展开更多
关键词 tube voltage contrast agent coronary CT angiography radiation dose iodine intake
下载PDF
Comparison of Various Parameters of DWI in Distinguishing Solitary Pulmonary Nodules 被引量:3
2
作者 han-xiong guan Yue-ying pAN +3 位作者 Yu-jin WANG Da-zong TANG Shu-chang ZHOU Li-ming Xia 《Current Medical Science》 SCIE CAS 2018年第5期920-924,共5页
In order to prospectively assess various parameters of diffusion weighted imaging (DWI)in differential diagnosis of benign and malignant solitary pulmonary nodules (SPNs),58 patients (40 men and 18 women,and mean age ... In order to prospectively assess various parameters of diffusion weighted imaging (DWI)in differential diagnosis of benign and malignant solitary pulmonary nodules (SPNs),58 patients (40 men and 18 women,and mean age of 48.1±10.4years old) with SPNs undergoing conventional MR,DWI using b=500s/mm^2 on a 1.5T MR scanner, were studied.Various DWI parameters [apparent diffusion coefficient (ADC),lesion-to-spinal cord signal intensity ratio (LSR),signal intensity (SI)score] were calculated and compared between malignant and benign SPNs groups.A receiver operating characteristic (ROC)curve analysis was employed to compare the diagnostic capabilities of all the parameters for discrimination between benign and malignant SPNs.The results showed that there were 42 malignant and 16 benign SPNs.The ADC was significantly,lower in malignant SPNs (1.40±0.44)×10^-3mm^2/s than in benign SPNs (1.81±0.58)×10^-3mm^2/ s.The LSR and SI scores were significantly increased in malignant SPNs (0.90±0.37 and 2.8±1.2)as compared with those in benign SPNs (0.68±0.39 and 2.2±1.2).The area under the ROC curves (AUC)of all parameters was not significantly different between malignant SPNs and benign SPNs.It was suggested that as three reported parameters for DWI,ADC,LSR and SI scores are all feasible for discrimination of malignant and benign SPNs.The three parameters have equal diagnostic performance. 展开更多
关键词 magnetic RESONANCE IMAGING diffusion WEIGHTED IMAGING SOLITARY PULMONARY NODULES differential diagnosis
下载PDF
IgG4-Related Disease:A Retrospective Chinese Study of Features and Treatment Response of 98 Patients Including 4 Rare Cases 被引量:1
3
作者 Yue-ying PAN Shu-chang ZHOU +3 位作者 Yu-jin WANG Ting-ting ZHU Dan PENG han-xiong guan 《Current Medical Science》 SCIE CAS 2021年第2期390-397,共8页
The features and treatment of 98 Chinese patients with immunoglobulin G4 (IgG4)-related disease (IgG4-RD) referred to a single tertiary referring centre were reviewed. Patientsdiagnosed with IgG4-RD according to the c... The features and treatment of 98 Chinese patients with immunoglobulin G4 (IgG4)-related disease (IgG4-RD) referred to a single tertiary referring centre were reviewed. Patientsdiagnosed with IgG4-RD according to the comprehensive diagnostic criteria (CDC) were includedin the retrospective study from May 2012 to March 2019. We collcted data on clinical, laboratory,imaging, histological features and treatment. Totally, 98 patients with IgG4-RD were enrolled.The common clinical manifestations included abdominal pain, salivary gland swelling andlymphadenopathy. 51% of the patients had multiple organs involvement. Lymph nodes, pancreasand salivary glands were most commonly involved. Four rare sites including ulna, cerebellum,scalp, and mammary gland were found. The serum IgG4 level was increased by 85.7%. The serumIgG4 level was positively correlated with the number of involved organs, IgG and IgG4/IgG. LowC3 and C4 levels were observed in 37.5% and 12.2% patients respectively, and all patients withkidney involvement had hypocomplementemia. A total of 54 patients underwent tissue biopsies,and 55.6%, 31.5% and 11.1% cases were diagnosed as definite, probable and possible IgG4-RD,respectively. Eighty-eight patients received glucocorticoids (GCs) therapy. Five patients underwentradical surgery to remove the lesion. 73% of them presented a complete or partial remission. IgG4-RD is a systemic fibroinflammatory disease with involvement of multiple organs throughout thebody including some rare sites. Most IgG4-RD patients had increased serum IgG4 levels andpatients with kidney involvement showed bypocomplementermia. GCs therapy is effective. Moreresearch is needed to provide a more reliable basis for the diagnosis and treatment of patients. 展开更多
关键词 immunoglobulin G4-related disease clinical features Immunoglobulin G4 hypocomplementemia GLUCOCORTICOID
下载PDF
Prospective Study of Low-and Standard-dose Chest CT for Pulmonary Nodule Detection:A Comparison of Image Quality,Size Measurements and Radiation Exposure
4
作者 Qiong-jie HU Yi-wen LIU +6 位作者 Chong CHEN Shi-chao KANG Zi-yan SUN Yu-jin WANG Min XIANG Li-ming XIA han-xiong guan 《Current Medical Science》 SCIE CAS 2021年第5期966-973,共8页
Objective:To comprehensively and accurately analyze the out-performance of low-dose chest CT(LDCT)vs.standard-dose CT(SDCT).Methods:The image quality,size measurements and radiation exposure for LDCT and SDCT protocol... Objective:To comprehensively and accurately analyze the out-performance of low-dose chest CT(LDCT)vs.standard-dose CT(SDCT).Methods:The image quality,size measurements and radiation exposure for LDCT and SDCT protocols were evaluated.A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols.Three experienced radiologists evaluated subjective image quality independently using a 5-point score system.Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics(size and volume).Radiation metrics and organ doses were analyzed using Radimetrics.Results:The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol.The sensitivity of LDCT for the detection of pulmonary nodules(n=650)was lower than that of SDCT(n=660).There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT(for BMI<22 kg/m^(2),4.37 vs.4.46 mm,and 43.66 vs.46.36 mm^(3);for BMI>22 kg/m^(2),4.3 vs.4.41 mm,and 41.66 vs.44.86 mm^(3))(P>0.05).The individualized volume CT dose index(CTDI_(vol)),the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group(all P<0.0001).This was especially true for dose-sensitive organs such as the lung(for BMI<22 kg/m^(2),2.62 vs.12.54 mSV,and for BMI>22 kg/m^(2),1.62 vs.9.79 mSV)and the breast(for BMI<22 kg/m^(2),2.52 vs.10.93 mSV,and for BMI>22 kg/m^(2),1.53 vs.9.01 mSV)(P<0.0001).Conclusion:These results suggest that with the increases in image noise,LDCT and SDCT exhibited a comparable image quality and sensitivity.The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol. 展开更多
关键词 pulmonary nodules tomography X-ray computed radiation dosage LUNG BREAST
下载PDF
Prevalence of Coronary Artery Fistula in a Single Center of China 被引量:1
5
作者 Yue-Ying Pan Gen Chen +4 位作者 Bin Chen Han-Lin Mu Yi-Qi Cheng He-Song Zeng han-xiong guan 《Chinese Medical Journal》 SCIE CAS CSCD 2018年第12期1492-1495,共4页
To the Editor: Coronary artery fistula (CAF), an unusual coronary anomaly, was first described in 1841 and it is defined as the abnormal communication between the coronary artery and the cardiac chamber or the grea... To the Editor: Coronary artery fistula (CAF), an unusual coronary anomaly, was first described in 1841 and it is defined as the abnormal communication between the coronary artery and the cardiac chamber or the great vessels. 展开更多
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部