期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Study of Luminous Emission from a Coaxial Plasma Discharge Device in the Presence of External Transverse Magnetic Field
1
作者 Tarek M. Allam hanaa a. el-sayed hanaa M. Soliman 《Energy and Power Engineering》 2011年第4期444-449,共6页
The experimental investigations in this paper are focused on the study of luminous radiation emission from coaxial plasma discharge device and the effect of applied transverse magnetic field Btr on it. The experiment ... The experimental investigations in this paper are focused on the study of luminous radiation emission from coaxial plasma discharge device and the effect of applied transverse magnetic field Btr on it. The experiment was done in (1.5 KJ - 10 KV) coaxial plasma discharge device. The discharge is operated in Nitrogen gas at pressures from 1 to 2.2 torr. Helmholtz magnetic coils are placed outside the coaxial electrodes with its axis at a distance = 3 cm from the coaxial electrodes muzzle, then Btr with a maximum induction ≈ 0.85 T is applied perpendicularly to the expanded plasma from the coaxial electrodes muzzle. The diagnostics used in the measurements include a Rogowsky coil and a photomultiplier tube equipped with light collimator. The experimental results showed that the maximum intensity of luminous radiation is detected at axial distance (side view) z = 8 cm and gas pressure, P = 2.2 torr. It also showed that the maximum value of axial luminous plasma zone velocity = 2.383 × 106 cm/s at z = 11 cm and P = 1.4 torr. In mode of presence of external Btr, the investigations have shown that, at P = 1.4 torr the maximum intensity of luminous radiation (detected at end-view position) is reduced by 17%, the full width at half maximum, FWHM of luminous radiation signal is increased by 40 times, while the luminous radiation signal is delayed by ta = 438 μs. In two modes of operation ta and FWHM have approximately a minimum values at P = 1.4 torr. 展开更多
关键词 COAXIAL DISCHARGE LUMINOUS Radiation TRANSVERSE Magnetic Field Energy LOSSES
下载PDF
Plasma Current Sheath Motion in Coaxial Plasma Discharge
2
作者 Tarek M. Allam hanaa a. el-sayed hanaa M. Soliman 《Energy and Power Engineering》 2011年第4期436-443,共8页
In this paper experiments and theoretical treatments [1] on 1.5 KJ coaxial plasma discharge device have been carried out to show, plasma current sheath, PCS, motion in coaxial plasma discharge by studying: the effect ... In this paper experiments and theoretical treatments [1] on 1.5 KJ coaxial plasma discharge device have been carried out to show, plasma current sheath, PCS, motion in coaxial plasma discharge by studying: the effect of nitrogen gas pressure in the range from 1 to 2.2 Torr and the axial position of PCS along the coaxial electrodes on the modification factor, actual drive parameter, PCS curvature and shape (thickness). Also the dynamics of PCS along the coaxial electrodes due to the combination effect of induced azimuthal and axial magnetic fields induction has been detected experimentally by using a magnetic probe technique. 展开更多
关键词 COAXIAL DISCHARGE Plasma Current SHEATH DRIVE PARAMETER
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部