期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Statistical analysis of ocular monochromatic aberrations in Chinese population for adaptive optics ophthalmoscope design
1
作者 Junlei Zha Fei Xiao +3 位作者 Jian Kang haoxin zhao Yun Dai Yudong Zhang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第1期84-93,共10页
It is necessary to know the distribution of the Chinese eye's aberrations in clinical environment to guide high-resolution retinal imaging system design for large Chinese population application.We collected the mo... It is necessary to know the distribution of the Chinese eye's aberrations in clinical environment to guide high-resolution retinal imaging system design for large Chinese population application.We collected the monochromatic wave aberration of 332 healthy eyes and 344 diseased eyes in Chinese population across a 6.0-mm pupil.The aberration statistics of Chinese eyes including healthy eyes and diseased eyes were analyzed,and some differences of aberrations between the Chinese and European race were concluded.On this basis,the requirement for adaptive optics(AO)correction of the Chinese eye's monochromatic aberrations was analyzed.The result showed that a stroke of 20μm and ability to correct aberrations up to the 8th Zernike order were needed for reflective wavefront correctors to achieve near difraction-limited imaging in both groups for a reference wavelength of 550 nm and a pupil diameter of 6.0mm.To verify the:analysis mentioned above,an A0 floodillumination system was established,and high-resolution retinal imaging in vivo was achieved for Chinese eye including both healthy and diseased eyes. 展开更多
关键词 Ocular aberrations adaptive optics retinal imaging.
下载PDF
Objective visual performance evaluation with visual evoked potential measurements based on an adaptive optics system
2
作者 杨彦荣 赵军磊 +4 位作者 赵豪欣 肖飞 谢佳欣 刘铁军 戴云 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第5期82-86,共5页
An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed throug... An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed through this system. Visual performance can be measured electrophysiologically with VEP, which reflects the objective func- tion from the retina to the primary visual cortex. The VEP ts without and with AO correction were preliminarily carried out using this system, demonstrating the great potential of this system in the objective visual performance evaluation. The new system will provide the necessary technique and equipment support for the further study of human visual function. 展开更多
关键词 VEP AO Objective visual performance evaluation with visual evoked potential measurements based on an adaptive optics system PSF
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部