Due to the advancement in wireless technology and miniaturization,Wireless Body Area Networks(WBANs)have gained enormous popularity,having various applications,especially in the healthcare sector.WBANs are intrinsical...Due to the advancement in wireless technology and miniaturization,Wireless Body Area Networks(WBANs)have gained enormous popularity,having various applications,especially in the healthcare sector.WBANs are intrinsically resource-constrained;therefore,they have specific design and development requirements.One such highly desirable requirement is an energy-efficient and reliable Data Aggregation(DA)mechanism for WBANs.The efficient and reliableDAmay ultimately push the network to operate without much human intervention and further extend the network lifetime.The conventional client-serverDAparadigm becomes unsuitable and inefficient for WBANs when a large amount of data is generated in the network.Similarly,in most of the healthcare applications(patient’s critical conditions),it is highly important and required to send data as soon as possible;therefore,reliable data aggregation in WBANs is of great concern.To tackle the shortcomings of the client-serverDAparadigm,theMobile Agent-Basedmechanismproved to be a more workable solution.In aMobile Agent-Based mechanism,a taskspecific mobile agent(code)traverses to the intended sources to gather data.Thesemobile agents travel on a predefined path called itinerary;however,planning a suitable and reliable itinerary for a mobile agent is also a challenging issue inWBANs.This paper presents a new Mobile Agent-Based DA scheme for WBANs,which is energy-efficient and reliable.Firstly,in the proposed scheme,the network is divided into clusters,and cluster-heads are selected.Secondly,a mobile agent is generated from the base station to collect the required data from cluster heads.In the case,if any fault occurs in the existing itinerary,an alternate itinerary is planned in real-time without compromising the network performance.In our simulation-based validation,we have found that the proposed system delivers significantly improved fault-tolerance and reliability with energy-efficiency and extended network lifetime in WBANs.展开更多
Customer satisfaction and participation in utility supply packages is the first and foremost factor in the success of any supplying agency whether wholesale or retail dealer. The paper presents the concept of major pr...Customer satisfaction and participation in utility supply packages is the first and foremost factor in the success of any supplying agency whether wholesale or retail dealer. The paper presents the concept of major prospects of non- autonomous micro-grids installed in a certain locality. The article shows the basic background that is required for the installment of micro grid in a particular area and discusses the primary factors or pre-requisites that are required for the existence and operation of micro-grids. It elaborate the major profitable applications and benefits that developing and developed states get by using micro-grids in an area where utility grid is already functioning .It also explains the basic improvement in the quality of supply from micro grid after its installment. It also throws light on afterwards impact on society with this system, such impacts include reliability, tariff rates, economics etc. The article discusses micro-grids as the future of modern power systems. This paper shows significance of modernization by latest topologies in power systems and its effect that will come afterwards.展开更多
As the revolutionary change in electric power industry begins with the latest communication infrastructure, it is on the verge of a revolutionary transformation to develop a smart grid to meet the requirements of our ...As the revolutionary change in electric power industry begins with the latest communication infrastructure, it is on the verge of a revolutionary transformation to develop a smart grid to meet the requirements of our digital society. Wide Area Power System is made up of plentiful automated transmission and distribution systems with strong communication infrastructure, all operating in a coordinated, proficient and reliable mode. This paper is fretful with the wide area power system load protection scheme and ensuing design requirement that enhances stability as well as control. It discusses the architecture that upgrades the existing scheme by controlling all the control signals traffic between generating units, server, connected loads, and protection devices using WIMAX. The main theme of the paper is on the use of information technology to obtain more flexibility and smartness in the Wide Area Power System Load Protection by designing the Communication channel using WIMAX. Faults detected in Local area networks and Information regarding the faults of Local Areas is communicated to Load Area Manager (LAM) which takes required control action to handle it. Finally the paper shows islanding operation through WAM for the areas that becomes intensive faulty. Results have been verified in MATLAB/ SIMULIMK.展开更多
基金This work was supported by the Basic Science Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(Grant No.NRF-2020R1I1A3074141)the Brain Research Program through the NRF funded by the Ministry of Science,ICT,and Future Planning(Grant No.NRF-2019M3C7A1020406),and the“Regional Innovation Strategy(RIS)”through the NRF funded by the Ministry of Education.
文摘Due to the advancement in wireless technology and miniaturization,Wireless Body Area Networks(WBANs)have gained enormous popularity,having various applications,especially in the healthcare sector.WBANs are intrinsically resource-constrained;therefore,they have specific design and development requirements.One such highly desirable requirement is an energy-efficient and reliable Data Aggregation(DA)mechanism for WBANs.The efficient and reliableDAmay ultimately push the network to operate without much human intervention and further extend the network lifetime.The conventional client-serverDAparadigm becomes unsuitable and inefficient for WBANs when a large amount of data is generated in the network.Similarly,in most of the healthcare applications(patient’s critical conditions),it is highly important and required to send data as soon as possible;therefore,reliable data aggregation in WBANs is of great concern.To tackle the shortcomings of the client-serverDAparadigm,theMobile Agent-Basedmechanismproved to be a more workable solution.In aMobile Agent-Based mechanism,a taskspecific mobile agent(code)traverses to the intended sources to gather data.Thesemobile agents travel on a predefined path called itinerary;however,planning a suitable and reliable itinerary for a mobile agent is also a challenging issue inWBANs.This paper presents a new Mobile Agent-Based DA scheme for WBANs,which is energy-efficient and reliable.Firstly,in the proposed scheme,the network is divided into clusters,and cluster-heads are selected.Secondly,a mobile agent is generated from the base station to collect the required data from cluster heads.In the case,if any fault occurs in the existing itinerary,an alternate itinerary is planned in real-time without compromising the network performance.In our simulation-based validation,we have found that the proposed system delivers significantly improved fault-tolerance and reliability with energy-efficiency and extended network lifetime in WBANs.
文摘Customer satisfaction and participation in utility supply packages is the first and foremost factor in the success of any supplying agency whether wholesale or retail dealer. The paper presents the concept of major prospects of non- autonomous micro-grids installed in a certain locality. The article shows the basic background that is required for the installment of micro grid in a particular area and discusses the primary factors or pre-requisites that are required for the existence and operation of micro-grids. It elaborate the major profitable applications and benefits that developing and developed states get by using micro-grids in an area where utility grid is already functioning .It also explains the basic improvement in the quality of supply from micro grid after its installment. It also throws light on afterwards impact on society with this system, such impacts include reliability, tariff rates, economics etc. The article discusses micro-grids as the future of modern power systems. This paper shows significance of modernization by latest topologies in power systems and its effect that will come afterwards.
文摘As the revolutionary change in electric power industry begins with the latest communication infrastructure, it is on the verge of a revolutionary transformation to develop a smart grid to meet the requirements of our digital society. Wide Area Power System is made up of plentiful automated transmission and distribution systems with strong communication infrastructure, all operating in a coordinated, proficient and reliable mode. This paper is fretful with the wide area power system load protection scheme and ensuing design requirement that enhances stability as well as control. It discusses the architecture that upgrades the existing scheme by controlling all the control signals traffic between generating units, server, connected loads, and protection devices using WIMAX. The main theme of the paper is on the use of information technology to obtain more flexibility and smartness in the Wide Area Power System Load Protection by designing the Communication channel using WIMAX. Faults detected in Local area networks and Information regarding the faults of Local Areas is communicated to Load Area Manager (LAM) which takes required control action to handle it. Finally the paper shows islanding operation through WAM for the areas that becomes intensive faulty. Results have been verified in MATLAB/ SIMULIMK.