Recently, thick haze and poisonous smoke have cloaked the surrounding air in Malaysia due to the uncontrollable and unethical burning of nearby country. This devastating episode of open burning started in the year 199...Recently, thick haze and poisonous smoke have cloaked the surrounding air in Malaysia due to the uncontrollable and unethical burning of nearby country. This devastating episode of open burning started in the year 1997 in Indonesia which deeply affected most of the ASEAN (association of southeast asian nations) countries especially their neighbour Malaysia and Singapore. The PV (photovoltaic) technology as an alternative means of energy generation experiences such significant energy decrease based on this condition which is due to the shading of sunlight. The 6 h claims of good sunlight has become not more than 2 h and gets worst when the API (air pollution index) struck 200 levels which is at very unhealthy condition. This study embraces some findings from 1 kWp PV generator field data installed in Malaysia reflecting the daily energy decrease operated during this unhealthy weather condition. It is found that, such significant energy decrease with the value of 0.43 W power output per increment of one point API. This value shows such concrete proof of additional factors to be considered in PV modelling in line to support PV technology adaptation in the ASEAN region.展开更多
文摘Recently, thick haze and poisonous smoke have cloaked the surrounding air in Malaysia due to the uncontrollable and unethical burning of nearby country. This devastating episode of open burning started in the year 1997 in Indonesia which deeply affected most of the ASEAN (association of southeast asian nations) countries especially their neighbour Malaysia and Singapore. The PV (photovoltaic) technology as an alternative means of energy generation experiences such significant energy decrease based on this condition which is due to the shading of sunlight. The 6 h claims of good sunlight has become not more than 2 h and gets worst when the API (air pollution index) struck 200 levels which is at very unhealthy condition. This study embraces some findings from 1 kWp PV generator field data installed in Malaysia reflecting the daily energy decrease operated during this unhealthy weather condition. It is found that, such significant energy decrease with the value of 0.43 W power output per increment of one point API. This value shows such concrete proof of additional factors to be considered in PV modelling in line to support PV technology adaptation in the ASEAN region.