The flowable latent heat storage material like Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enabled to transport the latent heat in a pipe. Supercooling phenome...The flowable latent heat storage material like Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enabled to transport the latent heat in a pipe. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase is obstructed by a latent heat storage. The latent heat storage rates of dispersed waterdrops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The waterdrops in emulsion have the diameter within 3 - 25 μm, the averaged diameter of waterdrops is 7.3 μm and the standard deviation is 2.9 μm. Supercooling release of waterdrops in emulsion is examined by short time impressing of the ultrasonic. The direct contact heat exchange method is chosen as the phase change rate evaluation of waterdrops in W/O emulsion. The supercooled temperature is set as parameters of this study. The previous obtained experimental result, as the condition without impressing ultrasonic wave, showed that the 35 K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It is clarified that it is possible to reduce 20 K of supercooling degree by impressing the ultrasonic.展开更多
The purpose of this study is to understand the factor that influence the heating efficiency of the outward and inward multi-hole gas burner. The flame-hole angle and the distance from flame hole to heating object are ...The purpose of this study is to understand the factor that influence the heating efficiency of the outward and inward multi-hole gas burner. The flame-hole angle and the distance from flame hole to heating object are chosen as the experimental parameters. The measurement of the flame temperature distribution is carried out on each experimental condition. The observation of combustion flame, by the Schlieren method, is done from the purpose to understand the combustion phenomenon on the heating efficiency. LPG (Liquefied petroleum gas) is used for the test fuel gas. The compositions of LPG are propane 97.5vol%, butane 0.2vol% and methane + ethylene 2.3vol%. The optimum ranges of the flame-hole angle and the distance from flame hole to heating object are clarified. The experimental correlation equations for the outward and inward multi-flame-hole gas burner are proposed.展开更多
Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand...Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand-concentration on day-time of summer by the air conditioning. The flowable latent heat storage material, Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enable to transport the latent heat in a pipe. The flowable latent heat storage material can realize the pipe size reduction and system efficiency improvement. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase brings the obstruction of latent heat storage. The latent heat storage rates of dispersed water drops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The water drops in emulsion has the diameter within 3 ~ 25μm, the averaged water drop diameter is 7.3μm and the standard deviation is 2.9μm. The direct contact heat exchange method is chosen as the phase change rate evaluation of water drops in W/O emulsion. The supercooled temperature and the cooling rate are set as parameters of this study. The evaluation is performed by comparison between the results of this study and the past research. The obtained experimental result is shown that the 35K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It was clarified that the supercooling rate of dispersed water particles in emulsion shows the larger value than that of the bulk water.展开更多
The purpose of this study is the development of latent heat transport system by using the mixture of the minute latent heat storage materials and the saccharine solution as medium. The experimental studies are carried...The purpose of this study is the development of latent heat transport system by using the mixture of the minute latent heat storage materials and the saccharine solution as medium. The experimental studies are carried out by the evaluation of viscosity and pressure loss in a pipe. Polyethylene (P.E.) is selected as the dispersed minute material that has closeness density (920kg/m3) of ice (917kg/m3). D-sorbitol and D-xylose solutions are picked as continuum phase of the test mixture. The concentration of D-sorbitol solution is set 48mass% from measured results of saturation solubility and the melting point. 40mass% solution of D-xylose is selected as the other test continuum phase. The non-ion surfactant, EA157 Dai-ichiseiyaku CO. Ltd, is used in order to prevent of dispersed P.E. powder cohere. The pressure loss of test mixture is measured by the straight circular pipe that has smooth inner surface. The measuring length for pressure loss is 1000 mm, and the inner diameter of pipe is 15mm. The accuracy of experiment apparatus for measuring pressure loss is within ±5%. The pressure loss data is estimated by the relationship between the heat transport ratio and the required pump power. It is clarified that the optimum range of mixing ratio exists over 10mass% of latent heat storage material.展开更多
文摘The flowable latent heat storage material like Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enabled to transport the latent heat in a pipe. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase is obstructed by a latent heat storage. The latent heat storage rates of dispersed waterdrops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The waterdrops in emulsion have the diameter within 3 - 25 μm, the averaged diameter of waterdrops is 7.3 μm and the standard deviation is 2.9 μm. Supercooling release of waterdrops in emulsion is examined by short time impressing of the ultrasonic. The direct contact heat exchange method is chosen as the phase change rate evaluation of waterdrops in W/O emulsion. The supercooled temperature is set as parameters of this study. The previous obtained experimental result, as the condition without impressing ultrasonic wave, showed that the 35 K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It is clarified that it is possible to reduce 20 K of supercooling degree by impressing the ultrasonic.
文摘The purpose of this study is to understand the factor that influence the heating efficiency of the outward and inward multi-hole gas burner. The flame-hole angle and the distance from flame hole to heating object are chosen as the experimental parameters. The measurement of the flame temperature distribution is carried out on each experimental condition. The observation of combustion flame, by the Schlieren method, is done from the purpose to understand the combustion phenomenon on the heating efficiency. LPG (Liquefied petroleum gas) is used for the test fuel gas. The compositions of LPG are propane 97.5vol%, butane 0.2vol% and methane + ethylene 2.3vol%. The optimum ranges of the flame-hole angle and the distance from flame hole to heating object are clarified. The experimental correlation equations for the outward and inward multi-flame-hole gas burner are proposed.
文摘Recently, much attention has been paid to investigate the latent heat storage system. Using of ice heat storage system brings an equalization of electric power demand, because it will solved the electric -power-demand-concentration on day-time of summer by the air conditioning. The flowable latent heat storage material, Oil/Water type emulsion, microencapsulated latent heat material-water mixture or ice slurry, etc., is enable to transport the latent heat in a pipe. The flowable latent heat storage material can realize the pipe size reduction and system efficiency improvement. Supercooling phenomenon of the dispersed latent heat storage material in continuous phase brings the obstruction of latent heat storage. The latent heat storage rates of dispersed water drops in W/O (Water/Oil) emulsion are investigated experimentally in this study. The water drops in emulsion has the diameter within 3 ~ 25μm, the averaged water drop diameter is 7.3μm and the standard deviation is 2.9μm. The direct contact heat exchange method is chosen as the phase change rate evaluation of water drops in W/O emulsion. The supercooled temperature and the cooling rate are set as parameters of this study. The evaluation is performed by comparison between the results of this study and the past research. The obtained experimental result is shown that the 35K or more degree from melting point brings 100% latent heat storage rate of W/O emulsion. It was clarified that the supercooling rate of dispersed water particles in emulsion shows the larger value than that of the bulk water.
基金supported by an Environment-Science-Aid 2005-2007 from Tottori prefecture, Japan
文摘The purpose of this study is the development of latent heat transport system by using the mixture of the minute latent heat storage materials and the saccharine solution as medium. The experimental studies are carried out by the evaluation of viscosity and pressure loss in a pipe. Polyethylene (P.E.) is selected as the dispersed minute material that has closeness density (920kg/m3) of ice (917kg/m3). D-sorbitol and D-xylose solutions are picked as continuum phase of the test mixture. The concentration of D-sorbitol solution is set 48mass% from measured results of saturation solubility and the melting point. 40mass% solution of D-xylose is selected as the other test continuum phase. The non-ion surfactant, EA157 Dai-ichiseiyaku CO. Ltd, is used in order to prevent of dispersed P.E. powder cohere. The pressure loss of test mixture is measured by the straight circular pipe that has smooth inner surface. The measuring length for pressure loss is 1000 mm, and the inner diameter of pipe is 15mm. The accuracy of experiment apparatus for measuring pressure loss is within ±5%. The pressure loss data is estimated by the relationship between the heat transport ratio and the required pump power. It is clarified that the optimum range of mixing ratio exists over 10mass% of latent heat storage material.