期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
An Advanced Oscillation Mixing Method for Improving the Cooling Uniformity in Quenching
1
作者 Hiroyuki Hoshino Hiromitsu Murakami +4 位作者 hideo yokota Satoshi Suda Hideki Tsuge Koichi Terasaka Toshiaki Wakabayashi 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第5期475-479,共5页
In quenching, the cooling uniformity is most important to diminish distortion occurring on work pieces. As a trial to accomplish uniform cooling, therefore, there exist various mixing methods of a quenchant and the qu... In quenching, the cooling uniformity is most important to diminish distortion occurring on work pieces. As a trial to accomplish uniform cooling, therefore, there exist various mixing methods of a quenchant and the quenchant circulation with an external pump has so far been the well accepted mixing method. However, this study proposes an advanced oscillation mixing method that can improve more the cooling uniformity in quenching. The proposed method includes a stirrer in oscillating motion, so that the simultaneous oscillating and mixing movements of the stirrer are considered to provide effectively the uniform cooling characteristics for the quenchant. In comparison with the case of the circulation pump mixing, the investigation using the oscillation mixing method has demonstrated the following two experimental facts: (1) the short vapor blanket stage caused by the quick breakage of the oil vapor blanket and (2) the reduced variation of the quenching distortion. 展开更多
关键词 淬火剂 冷却能力 变形 振动混合
下载PDF
Development of New Sliver Probe for Cooling Power Test of Polymer Quenchants
2
作者 Michiharu NARAZAKI Mamoru TAJIMA +4 位作者 Shigeru ASADA Katsumi ICHITANI hideo yokota Mitsugu TANAKA Youichi WATANABE 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第5期437-442,共6页
Working group on cooling power test of quenchants of Japanese Heat Treatment Society has studied on the new method for testing cooling power of aqueous quenchants. This method employed the cooling curve test of a new ... Working group on cooling power test of quenchants of Japanese Heat Treatment Society has studied on the new method for testing cooling power of aqueous quenchants. This method employed the cooling curve test of a new sliver rod probe, which has a metal-sheathed thermocouple at its geometrical center. The experimental study has clarified that the new silver probe has more excellent durability than the JIS silver probe employed for cooling power test of heat treating oils (JIS K 2242) and an aluminum alloy probe. Good repeatability and reproducibility of the cooling curves during polymer quenching have been confirmed. This new method is useful especially for cooling power test of aqueous quenchants used for solution heat treatment of aluminum alloys. This new silver rod probe is expected to be adopted for the revised version of JIS K 2242 as the cooling power test method for aqueous quenchants. 展开更多
关键词 聚合物淬火剂 动力试验 冷却曲线 银探测器
下载PDF
Standardization of New Sliver Probe for Cooling Power Test of Polymer Quenchant
3
作者 hideo yokota Katsumi ICHITANI +3 位作者 Kazuyoshi YAMAMOTO Hiroyuki IKUMI Yasufumi SUGIURA Michiharu NARAZAKI 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第5期447-452,共6页
Technical committee for Japanese industrial standard of heat treating oils has studied on the new method for testing cooling power of aqueous quenchants. This method employed the cooling curve test of a new sliver rod... Technical committee for Japanese industrial standard of heat treating oils has studied on the new method for testing cooling power of aqueous quenchants. This method employed the cooling curve test of a new sliver rod probe, which has a metal-sheathed thermocouple at its geometrical center. The experimental study has clarified that this probe has the higher sensitivity and excellent durability. In order to standardize this probe for cooling power test of aqueous quenchants, the repeatability and reproducibility of test results etc. have been studied. D.O.P. (Di-2-ethylthexyl Phthalate) was used as reference quenching fluid for initial calibration and for periodic calibration verification of the probe and system. In addition, 10% brine was used to check the response capability of the probe and system to the sudden change of temperature. These procedures are established according to the experimental investigation. This new test method is going to be built in the revised version of JIS K 2242 "Heat treating oils" as the cooling power test method for aqueous quenchants. 展开更多
关键词 聚合物淬火剂 冷却动力试验 冷却曲线 银探测器
下载PDF
Synchrotron Refraction Enhanced Tomography of an Intact Common Marmoset (<i>Callithrix jacchus</i>)
4
作者 Toshihiro Sera hideo yokota +6 位作者 SakikoS. Nakamura Kentaro Uesugi Masato Hoshino Naoto Yagi Toshio Ito Keigo Hikishima Hirotaka James Okano 《Open Journal of Radiology》 2011年第2期28-37,共10页
The common marmoset (Callithrix jacchus), a small new world monkey species, has been widely used in various scientific fields. It is necessary to understand connections between specific genotypes, their structure, and... The common marmoset (Callithrix jacchus), a small new world monkey species, has been widely used in various scientific fields. It is necessary to understand connections between specific genotypes, their structure, and function;however, an anatomical atlas of the entire body of the common marmoset has not yet been reported. In addition to conventional absorption, refraction enhanced computed tomography (CT) based on synchrotron radiation can increase the contrast of boundaries between small absorption differences. In this study, to examine the potential of creating an anatomical atlas of the whole body of the common marmoset non-invasively, we visualized an intact marmoset using synchrotron refraction enhanced CT. The cryogenic marmoset was scanned using the medical imaging beamline at the SPring-8 synchrotron radiation research facility in JAPAN. The trabecular structure, articular cartilage, cruciate ligament in the knee joint, and small airways (diameter: > 400 μm) was clearly identified with 50 μm voxel size and 37 keV x-ray energy. The structure of the heart and branching vessels in the kidneys and liver were also identified without contrast agents, and the anatomical structure of the brain was slightly visible. These results show that synchrotron refraction enhanced CT is useful for creating an anatomical atlas non-invasively, and further studies are planned that will combine refraction enhanced CT and other imaging techniques to analyse the morphology and create a complete atlas of the whole body of the common marmoset. 展开更多
关键词 Common MARMOSET CT REFRACTION Enhancement SYNCHROTRON
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部