Unsteady Flow Condition between Front and Rear Rotor of Contra-Rotating Small Sized Axial Fan 被引量:3
1
作者 Toru Shigemitsu hiroaki fukuda Katsuhiko Hirosawa 《Open Journal of Fluid Dynamics》 2017年第3期371-385,共15页
Contra-rotating small-sized axial fans are used as cooling fans for electric equipment. In the case of the contra-rotating rotors, the blade row distance between front and rear rotors is a key parameter for the perfor... Contra-rotating small-sized axial fans are used as cooling fans for electric equipment. In the case of the contra-rotating rotors, the blade row distance between front and rear rotors is a key parameter for the performance and stable operation. The wake and potential interference occur between the front and rear rotors and leakage flow from the front rotor tip influences on the flow condition of the rear rotor near the shroud when the blade row distance is small. Therefore, it is important to clarify the flow condition between front and rear rotors. The fan static pressure curves were obtained by the experimental apparatus and the numerical analysis was also conducted to investigate the internal flow between front and rear rotors. The leakage flow from the front rotor tip reaches the leading edge of the rear rotor when the blade row distance is small as L = 10 mm and the pressure fluctuations at the leading edge of the rear rotor tip becomes larger than those at other radial positions. In the present paper, the vorticity contour between front and rear rotors is shown and pressure fluctuations related to the leakage flow from the front rotor is investigated using the numerical analysis result. Then, suitable blade row distance for the contra-rotating small sized axial fan is discussed based on the internal flow condition. 展开更多
关键词 TURBOMACHINERY Contra-Rotating Axial FLOW FAN LEAKAGE FLOW WAKE
下载PDF
Performance and Internal Flow of Contra-Rotating Small-Sized Cooling Fan
2
作者 Toru Shigemitsu Keisuke Miyazaki +1 位作者 Katsuhiko Hirosawa hiroaki fukuda 《Open Journal of Fluid Dynamics》 2018年第2期181-194,共14页
High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rot... High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rotating rotors have been adopted for some of high pressure and large flow rate cooling fans to meet the demand. The performance curve of the contra-rotating small-sized cooling fan with 40 mm square casing was investigated by an experimental apparatus and its internal flow condition was clarified by the numerical analysis. The fan static pressure of the front rotor was extremely low and it increased significantly at the rear rotor. The uniform flow was achieved at the inlet of the rear rotor because of the special shape of the casing between the front and rear rotors. On the other hand, the tip leakage flow was large enough to influence on the main flow of the test cooling fan by the design specification of high pressure with compact rotor diameter. 展开更多
关键词 COOLING FAN Small-Sized AXIAL FAN Contra-Rotating Rotors PERFORMANCE INTERNAL Flow