An automatic monitoring electronic tongue based on differential pulse stripping voltammetry (DPSV) was developed for heavy metals analysis.Simultaneous detections of trace Zn(Ⅱ),Cd(Ⅱ),Pb(Ⅱ),Cu(Ⅱ),Fe(Ⅲ) and Cr(Ⅲ)...An automatic monitoring electronic tongue based on differential pulse stripping voltammetry (DPSV) was developed for heavy metals analysis.Simultaneous detections of trace Zn(Ⅱ),Cd(Ⅱ),Pb(Ⅱ),Cu(Ⅱ),Fe(Ⅲ) and Cr(Ⅲ) in water samples were performed with three electrochemical sensors.The sensor chip combined a silicon-based Hg-coated Au microelectrode array (MEA) as the working electrode on one side with an Ag/AgCl reference electrode and a Pt counter electrode on the other side.With a computer controlled multipotentiostat,pumps and valves,the electronic tongue realized in-situ real-time detection of the six metals mentioned above at parts-per-billion level without manual operation.展开更多
<正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser depositi...<正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser deposition PLD) technique is developed. High-purity chemical compound AgI:Ag_2S:HgI synthesized were used as target of PLD,thin film sensitive to Hg~ (2+) ion was prepared on the surface of LAPS.All-solide-state chalcogenide glass ion-selective electrodes ISE) ,Fe-ISE and Cr-ISE,were also used as targets of PLD,and thin-film sensors on different LAPS sensitive to Fe~ (3+) and Cr~ (6+) ions were prepared.The heavy metal analysis device with characteristics of collect sample in-site,real-time determination,communication and multifunction software were designed.Hardware design of the device mainly includes control and measurement aspects.The detected limits of Hg,Fe,Cr ions are 3.44×10~ (-7) mol/L,6.31×10~ (-6) mol/L and 2.09×10~ (-7) mol/L,respectively.展开更多
文摘An automatic monitoring electronic tongue based on differential pulse stripping voltammetry (DPSV) was developed for heavy metals analysis.Simultaneous detections of trace Zn(Ⅱ),Cd(Ⅱ),Pb(Ⅱ),Cu(Ⅱ),Fe(Ⅲ) and Cr(Ⅲ) in water samples were performed with three electrochemical sensors.The sensor chip combined a silicon-based Hg-coated Au microelectrode array (MEA) as the working electrode on one side with an Ag/AgCl reference electrode and a Pt counter electrode on the other side.With a computer controlled multipotentiostat,pumps and valves,the electronic tongue realized in-situ real-time detection of the six metals mentioned above at parts-per-billion level without manual operation.
文摘<正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser deposition PLD) technique is developed. High-purity chemical compound AgI:Ag_2S:HgI synthesized were used as target of PLD,thin film sensitive to Hg~ (2+) ion was prepared on the surface of LAPS.All-solide-state chalcogenide glass ion-selective electrodes ISE) ,Fe-ISE and Cr-ISE,were also used as targets of PLD,and thin-film sensors on different LAPS sensitive to Fe~ (3+) and Cr~ (6+) ions were prepared.The heavy metal analysis device with characteristics of collect sample in-site,real-time determination,communication and multifunction software were designed.Hardware design of the device mainly includes control and measurement aspects.The detected limits of Hg,Fe,Cr ions are 3.44×10~ (-7) mol/L,6.31×10~ (-6) mol/L and 2.09×10~ (-7) mol/L,respectively.