Automatic Monitoring Electronic Tongue with MEAs for Environmental Analysis
1
作者 Shaofang Zou hong men +2 位作者 Yi Li Yinping Wang Ping Wang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期381-384,共4页
An automatic monitoring electronic tongue based on differential pulse stripping voltammetry (DPSV) was developed for heavy metals analysis.Simultaneous detections of trace Zn(Ⅱ),Cd(Ⅱ),Pb(Ⅱ),Cu(Ⅱ),Fe(Ⅲ) and Cr(Ⅲ)... An automatic monitoring electronic tongue based on differential pulse stripping voltammetry (DPSV) was developed for heavy metals analysis.Simultaneous detections of trace Zn(Ⅱ),Cd(Ⅱ),Pb(Ⅱ),Cu(Ⅱ),Fe(Ⅲ) and Cr(Ⅲ) in water samples were performed with three electrochemical sensors.The sensor chip combined a silicon-based Hg-coated Au microelectrode array (MEA) as the working electrode on one side with an Ag/AgCl reference electrode and a Pt counter electrode on the other side.With a computer controlled multipotentiostat,pumps and valves,the electronic tongue realized in-situ real-time detection of the six metals mentioned above at parts-per-billion level without manual operation. 展开更多
关键词 electronic tongue heavy metals automatic monitoring microelectrode array multipotentiostat
下载PDF
A Heavy Metal Analysis Device Based on Light-addressable Potentiometric Sensor
2
作者 hong men Jianguo Wang +1 位作者 Jing Gao Ping Wang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期230-231,共2页
<正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser depositi... <正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser deposition PLD) technique is developed. High-purity chemical compound AgI:Ag_2S:HgI synthesized were used as target of PLD,thin film sensitive to Hg~ (2+) ion was prepared on the surface of LAPS.All-solide-state chalcogenide glass ion-selective electrodes ISE) ,Fe-ISE and Cr-ISE,were also used as targets of PLD,and thin-film sensors on different LAPS sensitive to Fe~ (3+) and Cr~ (6+) ions were prepared.The heavy metal analysis device with characteristics of collect sample in-site,real-time determination,communication and multifunction software were designed.Hardware design of the device mainly includes control and measurement aspects.The detected limits of Hg,Fe,Cr ions are 3.44×10~ (-7) mol/L,6.31×10~ (-6) mol/L and 2.09×10~ (-7) mol/L,respectively. 展开更多
关键词 analysis chemistry SENSOR heavy metal LAPS PLD