期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
CsI-bowl:an ancillary detector for exit channel selection inγ-ray spectroscopy experiments 被引量:1
1
作者 Xing-Chi Han Shuo Wang +5 位作者 hong-yi wu Zhi-Huan Li Guo-Zhu Shi Ruo-Fu Chen Yue-Zhao Zhang Shou-Yu Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期32-39,共8页
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,... A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels. 展开更多
关键词 Light charged particle detector array Particle identification Charge comparison method
下载PDF
An unexpected electrocardiogram sign of subacute left ventricular free wall rupture: Its early awareness may be lifesaving
2
作者 hong-yi wu Ju-ying Qian +1 位作者 Qi-bing Wang Jun-bo Ge 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2020年第2期117-119,共3页
BACKGROUND:Post-infarct left ventricular free wall rupture(LVFWR)is not always an immediately catastrophic complication.The rupture can be subacute,allowing time for diagnosis and intervention.Accordingly,early recogn... BACKGROUND:Post-infarct left ventricular free wall rupture(LVFWR)is not always an immediately catastrophic complication.The rupture can be subacute,allowing time for diagnosis and intervention.Accordingly,early recognition of the entity may be lifesaving.METHODS:We present an electrocardiogram(ECG)change pattern in two cases,which was erroneously attributed to ischemia.Two women in their 80s were admitted to our institute after experiencing the sudden onset of chest pain.They were managed as anterior ST-segment elevation myocardial infarction without reperfusion treatment.Unfortunately,they experienced a recurrence of severe chest pain with cardiogenic shock during hospitalisation.The ECG recorded at that time showed a ST-segment re-elevation in infract-related leads.RESULTS:The two cases were regrettably received a misjudgement of reinfarction at first,and one of the patients even was administrated with tirofi ban.Afterwards the diagnosis of subacute LVFWR was made through antemortem echocardiography.CONCLUSION:New ST-segment elevation(STE)in infarct-associated leads,coupled with recurrence of chest pain and new-onset hypotension,may constitute the premonitory signs of a subacute LVFWR. 展开更多
关键词 Myocardial infarction Myocardial rupture ELECTROCARDIOGRAM Diagnosis
下载PDF
Performance of the CAT-TPC based on two-dimensional readout strips 被引量:2
3
作者 Li-Sheng Yang Jin-Yan Xu +12 位作者 Qi-Te Li Bin-Fei Ji Zi-Wei Cai Jia-Xing Han Shi-Wei Bai Yan-Lin Ye Xiao-Fei Yang Chen-Gui Lu Ning-Tao Zhang Xiao-Dong Tang Jian Gao hong-yi wu Zhong Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期78-84,共7页
A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in uns... A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree. 展开更多
关键词 AT-TPC Readout strips Guard ring Three-dimensional image
下载PDF
Analysis of risk factors for early stent thrombosis in the Chinese population:A multicenter restrospective study 被引量:2
4
作者 Yu-peng Wang Lei Ding +11 位作者 Rui-tao Zhang Xiao-zeng Wang Dan-qing Yu Shou-yan Hao Jin-wei Tian Zhen-yu Liu Xiang-qian Qi Hu Tan hong-yi wu Feng-hua Ding Li-jun Guo Ya-ling Han 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2021年第3期192-197,共6页
BACKGROUND:The predictive scoring systems for early stent thrombosis(EST)remains blank in China.The study aims to evaluate the risk factors and conduct a prediction model of EST in the Chinese population.METHODS:EST w... BACKGROUND:The predictive scoring systems for early stent thrombosis(EST)remains blank in China.The study aims to evaluate the risk factors and conduct a prediction model of EST in the Chinese population.METHODS:EST was defined as thrombosis that occurs within the first 30 days after primary percutaneous coronary intervention(PCI).Patients from ten Chinese hospitals diagnosed as stent thrombosis(ST)from January 2010 to December 2016 were retrospectively included as the study group.A control group(1 case:2 controls)was created by including patients without ST,major adverse cardiovascular events,or cerebrovascular events during follow-up.The present study evaluated 426 patients with single-vessel lesions and ultimately included 40 patients with EST and 80 control patients,who were included to identify factors that predicted EST and to develop a prediction scoring system.The other 171 patients without integrated 1:2 pair were used for external validation.RESULTS:EST was independently associated with a low hemoglobin concentration(adjusted odds ratio[OR]0.946,95%confi dence interval[95%CI]0.901-0.993,P=0.026),a high pre-PCI Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery(SYNTAX)score(OR 1.166,95%CI 1.049-1.297,P=0.004),and a DAPT(DAPT)duration of<30 days(OR 28.033,95%CI 5.302-272.834,P<0.001).The simple EST prediction score provided an area under the curve(AUC)of 0.854(95%CI 0.777-0.932,P<0.001)with 70.0%sensitivity and 90.0%specifi city,and 0.742(95%CI 0.649-0.835,P<0.001)with 54.5%sensitivity and 81.0%specifi city for external validation dataset.CONCLUSIONS:EST may be independently associated with DAPT discontinuation within 30 days,a low hemoglobin concentration,and a high SYNTAX score.The scoring system also has a good ability to predict the risk of EST and may be useful in the clinical setting. 展开更多
关键词 Coronary heart disease Stent thrombosis Risk stratifi cation Predictive scoring system
下载PDF
Performance of digital data acquisition system in gamma-ray spectroscopy 被引量:2
5
作者 Di-Wen Luo hong-yi wu +9 位作者 Zhi-Huan Li Chuan Xu Hui Hua Xiang-Qing Li Xiang Wang Shuang-Quan Zhang Zhi-Qiang Chen Chen-Guang wu Yu Jin Jie Lin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期12-22,共11页
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr... A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion. 展开更多
关键词 Digital data acquisition system Gamma spectroscopy Energy resolution
下载PDF
丰中子区近^(132)Sn原子核的壳演化研究进展 被引量:1
6
作者 陈志强 李智焕 +4 位作者 吴婧 吴鸿毅 李湘庆 徐川 华辉 《科学通报》 EI CAS CSCD 北大核心 2021年第27期3537-3543,共7页
弱束缚区原子核传统幻数的消失和新幻数的产生一直是放射性核束物理的前沿研究方向.近年来,基于世界各地大科学装置的研究已经积累了丰硕的成果.在远离稳定线的轻丰中子区,人们已经发现8,20,28传统中子幻数的消失和新中子幻数14,16,34... 弱束缚区原子核传统幻数的消失和新幻数的产生一直是放射性核束物理的前沿研究方向.近年来,基于世界各地大科学装置的研究已经积累了丰硕的成果.在远离稳定线的轻丰中子区,人们已经发现8,20,28传统中子幻数的消失和新中子幻数14,16,34等的出现.在中重丰中子区,已有的实验和理论研究显示,50和82传统中子闭壳随着中质比的增大,有减弱直至消失的趋势.利用日本理化学研究所的放射性束流装置,我们开展了对^(123)Pd和^(125)Pd核的β衰变实验研究,在衰变子核^(123)Ag和^(125)Ag的低激发能区发现了具有β放射性的同核异能态.利用新发现的同核异能态,讨论了奇质量Ag同位素核中由πg9/2和πp1/2两个轨道形成的Z=40亚闭壳能隙在N=82附近的演化,发现在N=82处,Z=40亚闭壳能隙可能存在明显的减小.为进一步了解壳演化的微观机制,使用包含张量力的壳模型计算了这个质量区单粒子轨道的演化.结果显示,相比于N=50处,Z=40亚闭壳能隙在N=82处存在明显的减小,张量力对Ag同位素中πg9/2和πp1/2轨道以及Z=40亚闭壳能隙在接近N=82时的演化起到非常重要的作用. 展开更多
关键词 幻数 远离β稳定线 壳演化 张量力 N=82壳隙
原文传递
Investigation of the near-threshold cluster resonance in ^14C
7
作者 臧宏亮 叶沿林 +26 位作者 李智焕 王建松 楼建玲 李奇特 葛愉成 杨晓菲 李晶 蒋伟 冯俊 刘强 杨彪 陈志强 刘洋 吴鸿毅 牛晨阳 李晨光 王春光 王翔 刘威 高见 余翰舟 马军兵 马朋 白真 杨彦云 金仕纶 卢飞 《Chinese Physics C》 SCIE CAS CSCD 2018年第7期41-46,共6页
An experiment for m p(14C},14C*→10Be+α)p inelastic excitation and decay was performed in inverse kinematics at a beam energy of 25.3 MeV/u. A series of 14C excited states, including a new one at 18.3(1) MeV, w... An experiment for m p(14C},14C*→10Be+α)p inelastic excitation and decay was performed in inverse kinematics at a beam energy of 25.3 MeV/u. A series of 14C excited states, including a new one at 18.3(1) MeV, were observed which decay to various states of the final nucleus of 10Be. A specially designed telescope system, installed around zero degrees, played an essential role in detecting the resonant states near the α-separation threshold. A state at 14.1(1) MeV is clearly identified, being consistent with the predicted band-head of the molecular rotational band characterized by the π-bond linear chain configuration. Further clarification of the properties of this exotic state is suggested by using appropriate reaction tools. 展开更多
关键词 cluster decay linear-chain-state high detection efficiency inelastic excitation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部