An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ...An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
The influence of different concentration of oxalic acid matrix on elemental inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. It has been proved that the sensitivity of analytes can be sig...The influence of different concentration of oxalic acid matrix on elemental inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. It has been proved that the sensitivity of analytes can be significantly enhanced by adding small amounts of oxalic acid medium with adjusted nebulizer flow-rate gas, especially for the elements with ionization potential between 9 and 11 eV. Oxalic acid, as an enhancement agent, can be used to compensate the signal depression caused by inorganic matrix and to improve the detection limits about two to eight times, for the hard-to-ionize elements in ICP-MS determination.展开更多
基金supported by the Natural Science Foundation of Hunan Province(No.05JJ40017)Education Department of Hunan Province(No.05B064).
文摘An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.
基金This work was supported by Hunan Natural Science Foundation of China (No. 05JJ40017) Hunan Education Department of China (Project No. 05B064).
文摘The influence of different concentration of oxalic acid matrix on elemental inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. It has been proved that the sensitivity of analytes can be significantly enhanced by adding small amounts of oxalic acid medium with adjusted nebulizer flow-rate gas, especially for the elements with ionization potential between 9 and 11 eV. Oxalic acid, as an enhancement agent, can be used to compensate the signal depression caused by inorganic matrix and to improve the detection limits about two to eight times, for the hard-to-ionize elements in ICP-MS determination.