期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
APPLICATION OF WHOLE BODY DIFFUSION WEIGHTED MR IMAGING FOR DIAGNOSIS AND STAGING OF MALIGNANT LYMPHOMA 被引量:18
1
作者 Shuo Li hua-dan xue +5 位作者 Jian Li Fei Sun Bo Jiang Dong Liu Hong-yi Sun Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第3期138-144,共7页
Objective To evaluate the clinical impact of whole body diffusion weighted imaging (WB-DWI) on diagnosis and staging of malignant lymphoma. Methods Thirty-one patients with suspected lymphadenopathy were enrolled. ... Objective To evaluate the clinical impact of whole body diffusion weighted imaging (WB-DWI) on diagnosis and staging of malignant lymphoma. Methods Thirty-one patients with suspected lymphadenopathy were enrolled. WB-DWI was performed by using short TI inversion recovery echo-planar imaging sequence with free breathing and built-in body coil. Axial T2- weighted imaging images of the same location were used as reference. The results of WB-DWI were compared with pathological results and other imaging modalities. The mean apparent diffusion coefficient (ADC) values of different kinds of lymph nodes were compared. Results WB-DWI was positive in all 18 cases with lymphoma, 5 cases with metastatic lymph nodes and 4 of 8 eases with benign lymphadenopathy. The mean ADC value of lymphomatous, metastatic and benign lymph nodes was (0.87 ± 0.17) × 10^3, (0.98± 0.09) × 10^3 and (1.20 ± 0.10) × 10^3 mm^2/s. There was significant difference in ADC value between benign lymph nodes and other two groups (P 〈 0.01). The sensitivity, specificity and accuracy of WB-DWI in diagnosis of lymphoma were 100% (18/18), 30.8% (4/13) and 71.0% (22/31). When an ADC value of 1.08 × 10^-3 mm^2/s was used as the threshold value for differentiating malignant from benign lymph nodes, the best results were obtained with sensitivity of 87.8% and specificity of 91.3%. Sixteen of eighteen cases (88.9%) of lymphoma were accurately staged in accordance with clinical staging. Conclusions WB-DWI is a sensitive, but less specific technique for diagnosis of lymphoma. It is difficult to differentiate lymphnmatous from metastatic lymph nodes using WB-DWI. However, it is a valuable imaging modality for staging of patients with malignant lymphoma. 展开更多
关键词 diffusion magnetic resonance imaging whole body imaging short TI inversion recovery LYMPHOMA
下载PDF
CLINICAL APPLICATION OF BODY DIFFUSION WEIGHTED MR IMAGING IN THE DIAGNOSIS AND PREOPERATIVE N STAGING OF CERVICAL CANCER 被引量:28
2
作者 hua-dan xue Shuo Li +4 位作者 Fei Sun Hong-yi Sun Zheng-yu Jin Jia-xin Yang Mei Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第3期133-137,共5页
Objective To evaluate the clinical impact of body diffusion weighted imaging (DWI) on the diagnosis and preoperative N staging of cervical cancer. Methods Twenty-four patients (mean age 37.9 years old) with proved cer... Objective To evaluate the clinical impact of body diffusion weighted imaging (DWI) on the diagnosis and preoperative N staging of cervical cancer. Methods Twenty-four patients (mean age 37.9 years old) with proved cervical cancer by cervical biopsy and 24 female patients with other suspected pelvic abnormalities received preoperative body DWI scan. Results of body DWI were compared with pathological findings. The apparent diffusion coefficient (ADC) values of normal cervix and different pathological types of cervical cancer were compared. ADC value of normal or inflammatory lymph nodes was also compared with that of metastatic ones. Student's t test was used for statistical analysis. Results There were 5 adenocarcinomas and 19 epitheliomas showed with biopsy results, and DWI showed 21 cervical lesions out of them (87.5%). ADC values of the normal cervix (n = 24), epithelioma (n = 19), and adenocar- cinoma (n = 5) were (1.73 ± 0.31) ×10-3, (0.88 ± 0.22) ×10-3, and (1.08 ± 0.12) ×10-3 mm2/s, respectively. Statistical analysis showed significant difference in ADC value between normal cervical tissue and either tumor tissues (both P < 0.01). In patients had lymphadenectomy (n = 24), totally 67 lymph nodes including 16 metastatic lymph nodes were pathologically analyzed, and DWI showed 66 (98.5%) out of them. ADC values of normal/inflammatory and metastatic lymph nodes were (1.07 ± 0.16) ×10-3 and (0.77 ± 0.13) ×10-3 mm2/s (P < 0.01). Receiver operating characteristic (ROC) curve of ADC value of metastatic lymph node showed that area under curve was 0.961. Conclusions ADC value in cervical carcinoma is lower than that in normal cervix, and ADC may have predictive value in subtype discrimination. ADC value may improve the preoperative characterization of lymph node metastasis. And at least abdominal and pelvic DWI scan is suggested for N staging evaluation in such patients. 展开更多
关键词 magnetic resonance diffusion weighted imaging cervical cancer
下载PDF
WHOLE BODY DIFFUSION WEIGHTED IMAGING:A NEW ERA OF ONCOLOGICAL RADIOLOGY 被引量:16
3
作者 Zheng-yu Jin hua-dan xue Hua Tao 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第3期129-132,共4页
Cancer has become the leading cause of mortality in the urban area of China. Whole body diffusion weigntea imaging (WB-DWI), also known as virtual positron emission tomography, has gradually become accepted as an im... Cancer has become the leading cause of mortality in the urban area of China. Whole body diffusion weigntea imaging (WB-DWI), also known as virtual positron emission tomography, has gradually become accepted as an image tool in tumor localization, characterization, staging and monitoring response to therapy or tumor recurrence. Our article aimed to summarize the limited initial clinical use of WB-DWI in the referred area, and to analyze the most potential advantage of WB-DWI in therapeutic monitoring and tumor staging. WB-DWI as a highly sensitive, completely non-invasive, well-tolerated and low price technique has a promising furture in tumor assessment. Profound clinical study is necessary for its further application improvement. 展开更多
关键词 magnetic resonance imaging whole body imaging DIFFUSION
下载PDF
MR DIFFUSION WEIGHTED IMAGING FOR EVALUATION OF RADIOTHERAPEUTIC EFFECTS ON RABBIT VX2 TUMOR MODEL 被引量:15
4
作者 Shuo Li hua-dan xue +5 位作者 Xin-hai Wang Fei Sun Bo Jiang Dong Liu Jing Lei Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第3期172-177,共6页
Objective To investigate the feasibility of magnetic resonance (MR) diffusion weighted imaging (DWI) for evaluation of radiotherapeutic effects on rabbit VX2 tumor model. Methods Sixteen New Zealand white rabbits... Objective To investigate the feasibility of magnetic resonance (MR) diffusion weighted imaging (DWI) for evaluation of radiotherapeutic effects on rabbit VX2 tumor model. Methods Sixteen New Zealand white rabbits received a subcutaneous implantation of VX2 tumor cell suspension 0.5 mL (4× 10^7 ceUs/mL) in their right thighs to set up tumor model. And 2 weeks later they were randomly divided into therapy group (Group T, n = 10) and control group (Group C, n = 6). Group T received radiotherapy at a single dose of 10 Gy. MR imaging (MRI) scan including short TI inversion recovery echo-planar imaging DWI, T1-weighted imaging (T1WI) and T2-weighted imaging (T2WI) sequences were performed 1 day prior to as well as 1 day, 2 days, 3 days and 7 days after radiotherapy. Group C received only MRI scan at the same time points without any treatment. MRI appearance on T2WI, TlWI, and DWI images was compared and tumor volume was calculated. Apparent diffusion coefficient (ADC) values of the tumor were evaluated in all cases. HE staining was used for pathological study. Results Necrosis (n = 8) and hemorrhage (n = 2) were seen gradually on T2WI and T1WI images of Group T after time point of day 2 after irradiation. In Group C, no obvious necrosis was found until day 7. There was no significant difference in tumor volume between the two groups before radiotherapy. After radiotherapy, tumors in Group T showed a gradual growth but not as obvious as Group C. There was a significant difference in tumor volume between the two groups from day 2 on (P 〈 0.05). ADC value changed dramatically fight from the 1st day after radiotherapy in Group T [(0.99 ± 0.15) ×10^-3 mm^2/s for 1 day before radiotherapy, (1.23 ± 0.08) ×10^-3 , (1.45 ± 0.07) ×10^-3 , (1.63 ± 0.06) ×10^-3 , and (2.02 ± 0.18) ×10^-3 mm^2 for day 1, 2, 3, and 7]; and ADC value had no significant changes after radiotherapy in Group C except day 7 [(1.07±0.08) ×10^-3 mm^2 for 1 day before radiotherapy, (1.03 ± 0.04)×10^-3 , (1.05 ± 0.02)×10^-3 , (1.05 ± 0.05) ×10^-3 , and (0.95 ± 0.07) ×10^-3 mm^2 for day 1, 2, 3, and 7]. There was significant difference in ADC value between the two groups for each time point after radiotherapy (P 〈 0.01). Pathological study showed that the number of viable tumor cells in Group T decreased 1 day after radiotherapy, and the inflammatory cell infiltration was marked and almost all viable tumor cells disappeared by day 7 after radiotherapy. Conclusions DWI is a new promising technique for monitoring radiotherapy outcomes. ADC value may give a prior clue on physiological changes of radiotherapy before routine MRI could tell. 展开更多
关键词 diffusion magnetic resonance imaging RADIOTHERAPY animal experiment
下载PDF
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
5
作者 Hao Sun hua-dan xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source COMPUTED tomography iterative reconstruction imagequality radiation DOSE
下载PDF
Evaluation of Normal Adrenal Gland Volume by 64-slice CT 被引量:4
6
作者 Xuan Wang Zheng-yu Jin +4 位作者 hua-dan xue Wei Liu Hao Sun Yu Chen Kai Xu 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期220-224,共5页
Objective To measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the... Objective To measure volume and other parameters of normal adrenal glands in Chinese adults with 64-slice multidetector CT, to evaluate the relationship of volume result with age, sex and body size, and to explore the correlations between adrenal volume and other measurements. Methods This study was based on 125 acquired contrast-enhanced upper abdominal CT scans performed with a 64-slice CT. The final study group consisted of 81 patients (49 males, 32 females). Portal venous phase images were studied for the measurements. Both the reconstruction interval and thickness were 1.5 mm. Each adrenal gland was outlined manually with computer-assistant technology to calculate its volume. The maximal sectional area, length, width and thickness of each adrenal gland were also measured. Results The mean age of total population was 47.9±13.0 (range: 20-76) years. The left, right, and total adrenal gland volumes were 4.23±0.74 (range: 2.85-5.83) cm 3 , 4.26±0.86 (2.59-6.56) cm 3 , and 8.50±1.40 (5.80-11.39) cm 3 , respectively. These volumes increased with weight (r=0.381, 0.389, and 0.437 respectively, all P<0.001), height (r=0.386, P<0.001; r=0.297, P=0.007; r=0.384, P<0.001) and body surface area (r=0.406, 0.392, and 0.452, all P<0.001). There was no significant difference in left, right or total adrenal volume with regard to sex after applying General Linear Model procedure to reduce the impact of weight (F=1.304, 0.064, and 0.597, all P>0.05), nor did volume change significantly with age (r=-0.033, -0.014, and -0.026, all P>0.05). Nearly all descriptors of bilateral adrenal glands correlated with ipsilateral volume except thickness (r=-0.027, P=0.814) and width (r=0.166, P=0.138) in the left side. Among these parameters, length had a stronger correlation with volume than others in the both left (r=0.412, P<0.001) and right (r=0.516, P<0.001) adrenal glands. Conclusion Our study has defined the volume distribution and other parameters of normal adrenal glands in Chinese adults, which provide a baseline for future studies. 展开更多
关键词 adrenal gland VOLUMETRY volume determination computed tomography
下载PDF
Effects of Saline Administration, Abdominal Compression, and Prolongation of Acquisition Delay on Image Quality Improvement of CT Urography 被引量:7
7
作者 Hao Sun hua-dan xue +3 位作者 Wei Liu Xuan Wang Yu Chen Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期201-206,共6页
Objective To retrospectively evaluate the effects of saline administration following contrast material injection, abdominal compression and two delay phase acquisition on image quality improvement of computed tomograp... Objective To retrospectively evaluate the effects of saline administration following contrast material injection, abdominal compression and two delay phase acquisition on image quality improvement of computed tomographic urography (CTU). Methods Medical records and informed consents of patients were obtained. In totally 122 patients (50 men, 72 women), two delay phase images with CTU were performed. Scans began simultaneously with a contrast bolus injection of 100 mL (300 mgI/mL) followed by a saline bolus injection of 100 mL at a rate of 5 mL/s. Two delay phase images were taken at 400 and 550 seconds for each patient. Examinations were taken by using abdominal compression or not. The distention and opacification of the urinary tract were evaluated by two interpreters together on transverse images and post-processing images. Effects of four techniques (saline administration and abdominal compression, saline administration only, compression only, and neither saline administration nor compression) and two delay phase acquisition on image quality improvement were analysed by using ANOVA and Chi-square test. Results Saline administration improved opacification (P<0.05) and increased overall image quality (P<0.01) of the intrarenal collecting system and proximal ureter. Abdominal compression (P<0.05) and delayed phase image acquisition of 550 seconds (P<0.01) all improved distention of the intrarenal collecting system and proximal ureter but did not improve opacification. No statistically significant effects on the distal ureter were found. However, there were more visualized distal ureteral segments with the longer imaging delay. Conclusion Saline administration, abdominal compression and longer imaging delays are all effective in improving image quality of 64-detector row CTU. 展开更多
关键词 computed tomographic urography image quality
下载PDF
EXPERIMENTAL STUDY OF INFLAMMATORY AND METASTATIC LYMPH NODES WITH DIFFUSION WEIGHTED IMAGING ON ANIMAL MODEL: COMPARISON WITH CONVENTIONAL METHODS 被引量:3
8
作者 hua-dan xue Shuo Li +2 位作者 Hong-yi Sun Zheng-yu Jin Fei Sun 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第3期166-171,共6页
Objective To investigate the feasibility of magnetic resonance (MR) diffusion weighted imaging (DWI) in discriminating inflammatory from VX2 carcinoma metastatic lymph nodes in rabbit model. Methods Twenty New Ze... Objective To investigate the feasibility of magnetic resonance (MR) diffusion weighted imaging (DWI) in discriminating inflammatory from VX2 carcinoma metastatic lymph nodes in rabbit model. Methods Twenty New Zealand white rabbits were randomly divided into 2 groups. Complete Freund's adjuvant was injected into the bilateral dorsal footpads to set up ipsilateral lymphadenitis model (n = 10), and the other 10 rabbits received a subcutaneous implantation of VX2 tumor cell suspension (1.5×10^7 cells/mL) in both thighs to set up metastatic lymph node model. MR imaging scan covering the popliteal fossa and lilac fossa including short time inversion recovery echo-planar imaging DWI (STIR-EPI-DWI), Tl-weighted imaging (T1WI) and T2-weighted imaging (T2WI) was performed 2 weeks after injection. T2WI signal intensity (SI), DWI SI, long/short axial ratio (LSR) and apparent diffusion coefficient (ADC) values of the lymph nodes were evaluated in all cases. Right after MR imaging scan, popliteal and iliac fossa lymph nodes were collected for hematoxylin-eosin staining. Results Totally 33 lymph nodes larger than 5 turn, including 22 inflammatory and 11 metastatic ones, were successfully isolated and taken into pathological analysis. LSR showed no significant difference between the inflammatory and malignant lymph nodes (P 〉 0.05). Both benign and malignant lymph nodes appeared iso-intense on TlWI and hyperintense on both T2WI and DWI images with an even lower TlWI and higher T2WI SI core at the hilum. Both T2WI and DWI SI showed no significant difference between two pathological groups (P 〉 0.01) in popliteal fossa. The mean ADC value of inflammatory nodes [(1.199±0.281) ×10^-3 mm^2/s] was significantly higher than that of metastatic nodes [(0.858 ± 0.090) ×10^-3 mm^2/s, P 〈 0.01]. On ADC map, a high ADC value central area could be seen in most of the lymph nodes no matter benign or malignant. ADC value gave out the largest area under curve (AUCADC = 0.955) compared with other three indexes (AUCLsR = 0.488; AUCT2WI SI = 0.727; AUCDDWISI = 0.822) and gave the best sensitivity and specificity in lymph node differential diagnosis compared with the other three indexes. Conclusions High quality DWI image can be obtained using STIR-EPI-DWI sequence in rabbit model. DWI is a new promising technique for differentiating inflammatory from metastatic lymph nodes. Compared with routine MR sequence, DWI could provide more useful physiological and functional information for diagnosis. 展开更多
关键词 magnetic resonance diffusion weighted imaging lymph node
下载PDF
Clinical Value of Dual-energy CT in Detection of Pancreatic Adenocarcinoma: Investigation of the Best Pancreatic Tumor Contrast to Noise Ratio 被引量:2
9
作者 Yong-lan He Da-ming Zhang +1 位作者 hua-dan xue Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期207-212,共6页
Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 m... Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors. 展开更多
关键词 pancreatic adenocarcinoma DUAL-ENERGY contrast to noise ratio non-linear blending
下载PDF
SPECTRUM OF FUNCTIONING ISLET CELL TUMOR ON MULTISLICE COMPUTED TOMOGRAPHY:EXPERIENCE ON 70 PATIENTS 被引量:2
10
作者 hua-dan xue Wei Liu +7 位作者 Hao Sun Reto Merges Xuan Wang Xiao-na Zhang Yun Wang Wen-min Zhao Jiu-hong Chen Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2008年第1期1-9,共9页
Objective To review experience in preoperative detection of islet cell tumors using multislice computed tomography (MSCT) and summarize various imaging features of functioning islet cell tumors on enhanced MSCT. Me... Objective To review experience in preoperative detection of islet cell tumors using multislice computed tomography (MSCT) and summarize various imaging features of functioning islet cell tumors on enhanced MSCT. Methods Seventy patients with clinical or pathological diagnosis of functioning pancreatic islet cell tumor between October 2003 and February 2007 were included in this retrospective study. Seventy-four enhanced MSCT scans in these patients were identified. All MSCT scans were interpreted by two experienced radiologists by consensus interpretation. Surgery and pathology reports were used to confirm the diagnosis, localization, and size of tumors. Results Totally, 73 functioning islet cell tumors including 65 benign insulinomas, 2 benign glucagonomas, 3 malignant insulinomas, and 3 malignant glucagonomas were pathologically diagnosed. Tumors in only two cases were not found by MSCT. In 67 benign lesions, 32 showed typical enhancement style, 21 showed prolonged enhancement in portal venous phase, 4 showed delayed enhancement, 4 had iso-dense enhancement with normal pancreatic parenchyma, 2 had no enhancement at all in arterial phase and portal venous phase, and 4 had inhomogeneous enhancement with necrosis or cyst-formation. Patchy or spotty calcifications were found in 3 of the 67 tumors. In 6 malignant islet cell tumors, vessel invasion (2/6) and bowel invasion (1/6) were seen. Different enhancement patterns were shown. All hepatic metastases showed hyper-enhancement during their arterial phase. Conelttsions Pancreatic islet cell tumor may display a wide spectrum of presentations in MSCT. Tumors with unusual appearances often present as diagnostic challenges. Non-contrast and post-contrast multiphase scans are recommended for the localization of functioning islet cell tumors. 展开更多
关键词 islet cell tumor PANCREAS multislice computed tomography
下载PDF
Determinants of Detection of Stones and Calcifications in the Hepatobiliary System on Virtual Nonenhanced Dual-energy CT 被引量:1
11
作者 Da-ming Zhang Xuan Wang +4 位作者 hua-dan xue Zheng-yu Jin Hao Sun Yu Chen Yong-lan He 《Chinese Medical Sciences Journal》 CAS CSCD 2016年第2期76-82,共7页
Objective To retrospectively determine the features of stones and calcifications in hepatobiliary system on virtual nonenhanced (VNE) dual-energy computed tomography (CT), and to evaluate the possibility of VNE images... Objective To retrospectively determine the features of stones and calcifications in hepatobiliary system on virtual nonenhanced (VNE) dual-energy computed tomography (CT), and to evaluate the possibility of VNE images in diagnosis for those lesions. Methods A total of 128 gall stones and calcifications of the liver found in 110 patients were examined with triple phase abdominal CT scan from July 2007 to December 2011, in which true nonenhanced (TNE) phase and arterial phase were performed with single-energy CT (120 kVp) and portal venous phase was performed with dual-energy CT (100 kVp and 140 kVp). VNE images were generated from the portal venous phase dual-energy CT data sets by using commercially VNC software. The mean CT values for the stone, liver, bile and paraspinal muscle, mean lesion density and size in area dimension, contrast-to-noise ratio (CNR) of lesion to the liver or bile, and image noise were assessed and compared between VNE and TNE images. The effective dose and size-specific dose estimate (SSDE) were also calculated. Results The mean CT values of the lesions measured on VNE images declined significantly compared with those measured on TNE images (164.51±102.13vs. 290.72±197.80 HU,P<0.001), so did the lesion-to-liver CNR (10.80±11.82vs.18.81±17.06,P<0.001) and the lesion-to-bile CNR (17.24±14.41 vs. 21.32±17.31,P<0.001). There was no significant difference in size of lesions area between VNE and TNE images (0.69±0.88vs.0.72±0.85 cm2,P=0.062). Compared to the 128 lesions found in TNE images, VNE images showed the same density in 30 (23.4%) lesions, lighter density in 88 (68.8%) lesions, while failed to show 10 (7.8%) lesions, and showed the same size in 61 (47.7%) lesions and smaller size in 57 (44.5%)&nbsp;lesions. The CT cutoff values of lesion and size were 229.21 HU and 0.15 cm2, respectively. The total effective dose for triple phase scan protocol with TNE images was 19.51±7.03 mSv, and the SSDE was 39.84±11.10 mGy. The effective dose for dual phase scan protocol with VNE images instead of TNE images was 13.29±4.89 mSv, and the SSDE was 27.83±9.99 mGy. Compared with TNE images, the effective dose and SSDE of VNE images were down by 32.05%±3.69 % and 30.63%±2.34 %, respectively. Conclusions Although the CT values and CNR of the lesions decreased in VNE images, the lesions of which attenuation greater than 229.21 HU and size larger than 0.15 cm2could be detected with good reliability and obvious dose reduction. There was good consistency in the size of stones and calcifications in hepatobiliary system between VNE images and TNE images, which ensured the possibility of the clinical application of VNE images. 展开更多
关键词 virtual non-enhanced STONE CALCIFICATION hepatobiliary system dual-energy computed tomography
下载PDF
Life-threatening Spontaneous Retroperitoneal Haemorrhage:Role of Multidetector CT-angiography for the Emergency Management 被引量:1
12
作者 Zhi-wei Wang hua-dan xue +3 位作者 Xiao-guang Li Jie Pan Xiao-bo Zhang Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2016年第1期43-48,共6页
Objective To evaluate the role of multidetector computed tomography-angiography(MDCTA) for management of life-threatening spontaneous retroperitoneal haemorrhage(SRH).Methods A retrospective analysis of the medical re... Objective To evaluate the role of multidetector computed tomography-angiography(MDCTA) for management of life-threatening spontaneous retroperitoneal haemorrhage(SRH).Methods A retrospective analysis of the medical records of all SRH patients admitted to our hospital from January 1,2005 to November 31,2014 was performed.SRH was defined as unrelated to invasive procedures,surgery,trauma,abdominal tumor or aortic aneurysm.Life-threatening SRH was defined as hemodynamic instability with hypotension.Sixteen cases met the inclusive criteria.Patients' characteristics,clinical presentation,imaging of MDCTA,treatment modalities,morbidity,and follow-up data were analyzed.Results The group of 16 patients included 11 men and 5 women,with a mean age of 51.5 ± 16.4years.All patients underwent MDCTA scan examinations,and active contrast media(CM) extravasation were found in 9 patients.Angiography was performed for 8 patients in the CM extravasation group.Bleeding vessels were found in 7 patients who underwent successful embolization.One patient in the CM extravasation group did not undergo angiography and died of bleeding.Seven patients without active CM extravasation underwent conservative management.Bleeding was controlled for all these 7 patients,and 1 patient died of multiple organ failure.Fourteen patients survived from SRH were successfully discharged.One patient died of heart failure during follow-up.Conclusion MDCTA was useful in the diagnosis of SRH and proved to be predictive for the outcome of conservative treatment and early intervention. 展开更多
关键词 spontaneous retroperitoneal haemorrhage endovascular embolization contrast enhanced computed tomography
下载PDF
A Small Solitary Pulmonary Nodule Discovered by ^(18)F-fluorodeoxyglucose Positron Emission Tomography and CT: Rare Infection Instead of Rare Tumor
13
作者 Da-ming Zhang hua-dan xue +3 位作者 Lian Duan Ji Li Nai-shi Li Zheng-yu Jin 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期249-252,共4页
THE causes of Cushing's syndrome are mainly di- vided into adrenocorticotropic hormone (ACTH) dependent and independent. ACTH dependent hypercortisolism represents excess ACTH se-creting by the pituitary or tumor o... THE causes of Cushing's syndrome are mainly di- vided into adrenocorticotropic hormone (ACTH) dependent and independent. ACTH dependent hypercortisolism represents excess ACTH se-creting by the pituitary or tumor outside the pituitary; and the latter one is also called as ectopic ACTH syndrome. Thorax is the most common location of causative lesions for ectopic ACTH syndrome, and the size of lesion is too small to be detected in some cases.1' 2 Cryptococcal pneumonia usually occurs in immunocompromised patients and excess cortisol production can theoretically produce a state of immunodeficiency. Development of cryptococcal pneumonia concomitant with Cushing syndrome (CS) was rare. Here, we report a case of pulmonary nodule in a patient with CS differentiated with ectopic ACTH-producing tumor. Crypto- coccal pneumonia was diagnosed followinglung resection. 展开更多
关键词 Cushing syndrome pulmonary cryptococcosis ectopic adrenocorticotropichormone-producing tumor
下载PDF
Primary Squamous Cell Carcinoma of the Small Intestine: Pathogenesis and Clinical Features 被引量:2
14
作者 Feng-Dan Wang Zhi-WeiWang +4 位作者 hua-dan xue Huan-Wen Wu Yan Zhang Jian-Chun Yu Zheng-Yu Jin 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第17期2131-2133,共3页
Relative to the length and surface area of the gastrointestinal tract, malignant tumors of the small intestine are remarkably rare, with a global incidence of〈1 per 100,000 population. Among the forty different histo... Relative to the length and surface area of the gastrointestinal tract, malignant tumors of the small intestine are remarkably rare, with a global incidence of〈1 per 100,000 population. Among the forty different histological subtypes of small intestinal cancers, primary squamous cell carcinoma (SCC) is exceptionally rare with only occasional case reports in literature. The present study reported a case of primary SCC of the small intestine and reviewed all cases reported in English literature to provide a systematic overview of this rare disease. 展开更多
关键词 Positron Emission Tomography Primary Squamous Cell Carcinoma Small Intestine
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部