The surface pressure-area (pi -A) isotherm of Schiff base aluminium (III), tris (2-hydroxy-5-nitro-N-dodecyl-benzylideneaminato) aluminium (III) (denoted as Al(TAl2)(3)), on pure water subphase was investigated. The m...The surface pressure-area (pi -A) isotherm of Schiff base aluminium (III), tris (2-hydroxy-5-nitro-N-dodecyl-benzylideneaminato) aluminium (III) (denoted as Al(TAl2)(3)), on pure water subphase was investigated. The molecular area, 0.48 nm(2), is one-third of expected value that indicated the aggregation took place. The Langmuir-Blodgett (LB) films of Al(TAl2), was transferred and characterized. The AFM image confirmed the formation of aggregates.展开更多
In this work, the self-assembled monolayer of Schiff base was first investigated using electrochemical impedance spectroscopy (EIS). The complexation Of Cu2+ with the Schiff base: was also detected with EIS method. Th...In this work, the self-assembled monolayer of Schiff base was first investigated using electrochemical impedance spectroscopy (EIS). The complexation Of Cu2+ with the Schiff base: was also detected with EIS method. The approximate linear relationship between Cu2+ and the reaction resistance (R-r) was observed. All the results suggest that the electrochemical property of Schiff base could be studied conveniently by means of forming self-assembled monolayer.展开更多
A highly selective nitric oxide(NO) sensor is fabricated and applied to devise an enhanced flow injection analysis(FIA) system for S-nitrosothiols(RSNOs) measurement in biological samples.The NO sensor is prepar...A highly selective nitric oxide(NO) sensor is fabricated and applied to devise an enhanced flow injection analysis(FIA) system for S-nitrosothiols(RSNOs) measurement in biological samples.The NO sensor is prepared using a polytetrafluoroethylene(PTFE) gas-permeable membrane loaded with Teflon AF? solution,a copolymer of tetrafluoroethylene and 2,2-bis(trifluoroethylene)-4,5-difluoro -l,3-dioxole,to improve selectivity.This method is much simpler and possesses good performance over a wide range of RSNOs concentrations.Standard deviation for three parallel measurements of blood plasma is 4.0%.The use of the gas sensing configuration as the detector enhances selectivity of the FIA measurement vs.using less selective electrochemical detectors that do not use PTFE/Teflon type outer membranes.展开更多
基金the NSFC (29973026, 29773017) and Beijing Natural Science Foundation (2992007) for the provision of financial support.
文摘The surface pressure-area (pi -A) isotherm of Schiff base aluminium (III), tris (2-hydroxy-5-nitro-N-dodecyl-benzylideneaminato) aluminium (III) (denoted as Al(TAl2)(3)), on pure water subphase was investigated. The molecular area, 0.48 nm(2), is one-third of expected value that indicated the aggregation took place. The Langmuir-Blodgett (LB) films of Al(TAl2), was transferred and characterized. The AFM image confirmed the formation of aggregates.
基金the NSFC (29973026) and Beijing Natural Science Foundation (2992007).
文摘In this work, the self-assembled monolayer of Schiff base was first investigated using electrochemical impedance spectroscopy (EIS). The complexation Of Cu2+ with the Schiff base: was also detected with EIS method. The approximate linear relationship between Cu2+ and the reaction resistance (R-r) was observed. All the results suggest that the electrochemical property of Schiff base could be studied conveniently by means of forming self-assembled monolayer.
基金the Project of Base for Introducing Talents of Discipline to Universities(111 project,NoB07012)National Scholarship Fund of the China Scholarship Council for supporting visiting students in foreign universities
文摘A highly selective nitric oxide(NO) sensor is fabricated and applied to devise an enhanced flow injection analysis(FIA) system for S-nitrosothiols(RSNOs) measurement in biological samples.The NO sensor is prepared using a polytetrafluoroethylene(PTFE) gas-permeable membrane loaded with Teflon AF? solution,a copolymer of tetrafluoroethylene and 2,2-bis(trifluoroethylene)-4,5-difluoro -l,3-dioxole,to improve selectivity.This method is much simpler and possesses good performance over a wide range of RSNOs concentrations.Standard deviation for three parallel measurements of blood plasma is 4.0%.The use of the gas sensing configuration as the detector enhances selectivity of the FIA measurement vs.using less selective electrochemical detectors that do not use PTFE/Teflon type outer membranes.