期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Studies of the linearity of the readout module assembling using the eXTP-GPD chips
1
作者 Jiechen Jiang Liang Sun +9 位作者 Yang Jiao Weichun Jiang Yupeng Xu huilin he Xiaohua Liu Yuanyuan Du Sheng Yang Zefang Dong Xiaojing Liu Boyu Dai 《Radiation Detection Technology and Methods》 CSCD 2023年第2期255-262,共8页
Background The Gas Pixel Detector(GPD)is a key part of the Polarimetry Focusing Array(PFA)sub-system onboard the enhance X-ray Timing and Polarimetry mission(eXTP).The GPD can accurately provide the polarized angle an... Background The Gas Pixel Detector(GPD)is a key part of the Polarimetry Focusing Array(PFA)sub-system onboard the enhance X-ray Timing and Polarimetry mission(eXTP).The GPD can accurately provide the polarized angle and degree for incoming soft X-rays(requirements of minimum detectable polarization<1%(10^(6) s,1 mCrab))from celestial objects under extreme conditions of density,gravity and magnetism.Purpose Paste the GPD chips on a matched ceramic package is one of the most important procedures for the GPD assembly,and the parallelism between the top surface of an ASIC chip and the bottom surface of a Gas Electron Multiplier(GEM)foil can have impact on the distribution of electric field within transfer region and reconstruction of photoelectric trajectories,resulting in deterioration of the GPD sensitivity.This study quantifies the influence and gives a reasonable expectation of the parallelism.Methods A simulation framework of the GPD is constructed to quantify the influence on the GPD performance and values of the parallelism are measured by a gauge with a position resolution of o.1μm.Results:The difference of degree of modulation is less than 1% comparing the parallelism with a value of 20μm to a value of 0μm in response to both polarized and unpolarized X-rays.Meanwhile,the value of parallelism can reach 6.9±3.4μm(0.0176°±0.0087°)by testing and verifying.Conclusions The impact on the GPD performance can be less than 1%as the parallelism with an order of 20μm,and we also give a reasonable measuring method and verify the controllability and feasibility of the parallelism with an order of 20μm for pasting the ASIC chip on the surface of a ceramic package. 展开更多
关键词 PARALLELISM Gas pixel detectors Gaseous detector simulation Measurements
原文传递
Three-dimensional parametric contact analysis of planetary roller screw mechanism and its application in grouping for selective assembly
2
作者 huilin he Peitang WEI +4 位作者 Huaiju LIU Xuesong DU Rui HU Genshen LIU Yajun WU 《Frontiers of Mechanical Engineering》 SCIE CSCD 2024年第1期53-72,共20页
The planetary roller screw mechanism(PRSM)is a novel precision transmission mechanism that realizes the conversion between linear and rotary motions.The contact characteristics of helical surfaces directly determine P... The planetary roller screw mechanism(PRSM)is a novel precision transmission mechanism that realizes the conversion between linear and rotary motions.The contact characteristics of helical surfaces directly determine PRSM’s performance in load-carrying capacity and transmission accuracy.Therefore,studying the contact characteristics of PRSM forms the fundamental basis for enhancing its transmission performance.In this study,a three-dimensional parametric analysis method of contact characteristics is proposed based on the PRSM meshing principle and PyVista(a high-level API to the Visualization Toolkit).The proposed method considers the influence of machining errors among various thread teeth.The effects of key machining errors on contact positions and axial clearance,as well as their sensitivities,are analyzed.With excellent solution accuracy,this method exhibits higher calculation efficiency and stronger robustness than the analytical and numerical meshing models.The influence of nominal diameter and pitch errors of the screw,roller,and nut on the axial clearance follows a linear relationship,whereas flank angle errors have negligible effects on the axial clearance.The corresponding influence coefficients for these three machining errors on the axial clearance are 0.623,0.341,and 0.036.The variations in contact positions caused by individual errors are axisymmetric.Flank angle errors and roller diameter errors result in linear displacements of the contact points,whereas pitch errors cause the contact points to move along the arc of the roller diameter.Based on the proposed threedimensional parametric contact characteristics analysis method,the Fuzzy C-Means clustering algorithm considering error sensitivity is utilized to establish a component grouping technique in the selective assembly of critical PRSM components,ensuring the rational and consistent clearances based on the given component’s machining errors.This study provides effective guidance for analyzing contact characteristics and grouping in selective assembly for PRSM components.It also presents the proposed method’s potential applicability to similar calculation problems for contact positions and clearances in other transmission systems. 展开更多
关键词 planetary roller screw mechanism(PRSM) contact position axial clearance machining error grouping for selective assembly
原文传递
Study on direct point spread function measurement of capillary plate collimators with divergent X-ray beams
3
作者 Tianming Li Tao Luo +2 位作者 Yupeng Xu huilin he Liming Song 《Radiation Detection Technology and Methods》 CSCD 2023年第3期321-336,共16页
Purpose The Filed of View(FOV)of eXTP/LAD is limited by lead-glass capillary plate collimators placed in front of the Silicon Drift Detectors(SDDs)for reducing the background contamination caused by the photons of Cos... Purpose The Filed of View(FOV)of eXTP/LAD is limited by lead-glass capillary plate collimators placed in front of the Silicon Drift Detectors(SDDs)for reducing the background contamination caused by the photons of Cosmic X-ray Background(CXB)leaking from outside the FOV.The core quality parameters of lead-glass capillary plate collimators are Open Area Ratio(OAR)and FOV.The performance of lead-glass capillary plate collimators is determined by its design specification such as pore-to-pore misalignment,pore perpendicularity with collimator surface and pore diameter.Since the design specification is the result of a large number of micropores,we use the full width at half maximum(FWHM)and peak value of point spread function(PSF)to characterize the capillary plate collimator performance.In order to quickly evaluate the performances of collimators,we developed a direct PSF measurement method using divergent beams.Methods In this paper,the simulation package of the divergent beamsmeasurement setup is developed based on Geant4.The simulation parameters of scintillator absorption length are corrected by experimental data.We simulate the PSF of collimators with different distribution of pore diameter and misalignment by parallel beams and divergent beams.By comparing the peak value and FWHM of collimators PSF,the feasibility in replacing parallel beams measurement with divergent beams measurement is studied.Results It is verified that the influence of the geometric size of 33μm radius of the micro-focus of X-ray tube can be ignored.The results show that the FWHM of collimators is increased with error root mean square error(RMS)of the distribution of collimators pore diameter and pore inclination angle.The peak value of PSF is mainly influenced by pore non-parallelism of the pores,and it decreases with an increase in pore inclination angle.Comparison of parallel beams PSF and divergent beams PSF shows well consistency of peak value and FWHM of collimator.But,the peak value of the divergent beams PSF is mainly affected by the defects of the pores close to the optical axis and result in difference from the parallel beams results consequently.We have developed capillary plate collimators response function based on the projected area function of a cylindrical pore and the fluorescence broadening of the scintillator and fitted PSF by response function.The capillary plate collimator open area ratio is calculated by using the micropores radius and collimator frame thickness obtained by fitting parameter,and the result is close to the parallel beams PSF.Conclusion The feasibility divergent beams measurement is verified. 展开更多
关键词 GEANT4 EXTP/LAD Capillary plate collimators Divergent X-ray beams measurment
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部