Hydric properties evolution during drying differs from one product to another and has been the subject of various studies due to its crucial importance in modeling the drying process. The variation of these parameters...Hydric properties evolution during drying differs from one product to another and has been the subject of various studies due to its crucial importance in modeling the drying process. The variation of these parameters in the solid matrix and in time during the drying of Spirulina platensis has not known an advanced understanding. The objective of this study was to evaluate the evolution of the water content profile, the mass flow, the concentration gradient and the diffusion coefficient during the drying of Spirulina platensis taking into account the shrinkage. Modeling and experimental analysis (at 50°C and HR = 6%) by the cutting method a cylinder 20 mm in diameter and 40 mm thick were carried. The water content profiles of two different products grown in semi-industrial farms from Burkina Faso and France with initial water contents respectively of the range from 2.73 kgw/kgdb and 3.12 kgw/kgdb were determined. These profiles have been adjusted by a polynomial function. Identical water behavior is observed regardless of the origin of the samples. Water distribution is heterogeneous. Mass flow and concentration gradient are greater at the edge than inside the product. The water transport coefficient, ranging from 1.70 × 10?10 to 94 × 10?10 m2/s, is determined from a linear approach.展开更多
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura...This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection.展开更多
The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, espec...The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, especially water pumping systems, are beginning to emerge in large applications. In this sense, the proposed study deals with the problem of the water level regulation in the photovoltaic pumping system. It is in this context that the interest in this paper is dictated by the need to use an existing energy source on the site. Still in this light, it is important to note that, often, the calculation of the size of the GPV that feeds the pumping system and the pump involves a certain degree of uncertainty, mainly due to two main reasons: the first is related to randomness of solar radiation which is often little known and the second is related to the difficulty to estimate the water needs. This is why, on the one hand, the realization of such a system has made it possible to show the possibility of determining the projected quantity for water storage. Similarly, it has shown that the prediction of this quantity of water can be calculated by a simple analytical method based on numerical computation. Thus, it was also shown for this pumping system, thanks to graphical analysis methods, developing autonomy, reliability and good performance. In this sense, this experience opens the door for a practical and economical solution to the problem of lack of water, especially in our regions. Measurements made on the studied system prove that the designed approach improves the efficiency. Finally, it is also expected to draw further conclusions for the operation of these systems in similar sites.展开更多
文摘Hydric properties evolution during drying differs from one product to another and has been the subject of various studies due to its crucial importance in modeling the drying process. The variation of these parameters in the solid matrix and in time during the drying of Spirulina platensis has not known an advanced understanding. The objective of this study was to evaluate the evolution of the water content profile, the mass flow, the concentration gradient and the diffusion coefficient during the drying of Spirulina platensis taking into account the shrinkage. Modeling and experimental analysis (at 50°C and HR = 6%) by the cutting method a cylinder 20 mm in diameter and 40 mm thick were carried. The water content profiles of two different products grown in semi-industrial farms from Burkina Faso and France with initial water contents respectively of the range from 2.73 kgw/kgdb and 3.12 kgw/kgdb were determined. These profiles have been adjusted by a polynomial function. Identical water behavior is observed regardless of the origin of the samples. Water distribution is heterogeneous. Mass flow and concentration gradient are greater at the edge than inside the product. The water transport coefficient, ranging from 1.70 × 10?10 to 94 × 10?10 m2/s, is determined from a linear approach.
文摘This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection.
文摘The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, especially water pumping systems, are beginning to emerge in large applications. In this sense, the proposed study deals with the problem of the water level regulation in the photovoltaic pumping system. It is in this context that the interest in this paper is dictated by the need to use an existing energy source on the site. Still in this light, it is important to note that, often, the calculation of the size of the GPV that feeds the pumping system and the pump involves a certain degree of uncertainty, mainly due to two main reasons: the first is related to randomness of solar radiation which is often little known and the second is related to the difficulty to estimate the water needs. This is why, on the one hand, the realization of such a system has made it possible to show the possibility of determining the projected quantity for water storage. Similarly, it has shown that the prediction of this quantity of water can be calculated by a simple analytical method based on numerical computation. Thus, it was also shown for this pumping system, thanks to graphical analysis methods, developing autonomy, reliability and good performance. In this sense, this experience opens the door for a practical and economical solution to the problem of lack of water, especially in our regions. Measurements made on the studied system prove that the designed approach improves the efficiency. Finally, it is also expected to draw further conclusions for the operation of these systems in similar sites.