期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure 被引量:1
1
作者 Elsa L.C.Mai ie-bin lian David C.K.Chang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第12期1798-1801,共4页
AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.METHODS: Patients were recruited from a refractive... AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.METHODS: Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test.RESULTS: For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare.CONCLUSION: INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions. 展开更多
关键词 INTRACOR LASIK contrast sensitivity intrastromal femtosecond laser
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部