A chemo-mechanical model is developed to investigate the effects on the stress development of the coating of polycrystalline Ni-rich LiNixMnyCo_(z)O_(2)(x≥0.8)(NMC)particles with poly(3,4-ethylenedioxythiophene)(PEDO...A chemo-mechanical model is developed to investigate the effects on the stress development of the coating of polycrystalline Ni-rich LiNixMnyCo_(z)O_(2)(x≥0.8)(NMC)particles with poly(3,4-ethylenedioxythiophene)(PEDOT).The simulation results show that the coating of primary NMC particles significantly reduces the stress generation by efficiently accommodating the volume change associated with the lithium diffusion,and the coating layer plays roles both as a cushion against the volume change and a channel for the lithium transport,promoting the lithium distribution across the secondary particles more homogeneously.Besides,the lower stiffness,higher ionic conductivity,and larger thickness of the coating layer improve the stress mitigation.This paper provides a mathematical framework for calculating the chemo-mechanical responses of anisotropic electrode materials and fundamental insights into how the coating of NMC active particles mitigates stress levels.展开更多
Interpretation of quantitative results of nerve fiber layer (NFL) thickness based on scanning laser polarimetry (GDx-NFA) can be quite challenging especially in glaucoma suspects. Purpose: Authors studied NFL paramete...Interpretation of quantitative results of nerve fiber layer (NFL) thickness based on scanning laser polarimetry (GDx-NFA) can be quite challenging especially in glaucoma suspects. Purpose: Authors studied NFL parameters obtained from GDx-NFA in glaucoma suspects and compared them with those of patients with glaucoma Methods: Eighty six glaucoma suspects based展开更多
Frequency doubling perimetry (FDP) may idendtify glaucoma at a relatively early stage even before conventional perimetry does. Scanning laser polarimetry (GDx) has shown to differentiate nerve fiber layer thickness (N...Frequency doubling perimetry (FDP) may idendtify glaucoma at a relatively early stage even before conventional perimetry does. Scanning laser polarimetry (GDx) has shown to differentiate nerve fiber layer thickness (NFLT) between glaucomatous展开更多
Purpose The Large Hadron Collider(LHC)at European Organization for Nuclear Research is planned to be upgraded to the high luminosity LHC.Increasing the luminosity makes muon triggering reliable and offline reconstructi...Purpose The Large Hadron Collider(LHC)at European Organization for Nuclear Research is planned to be upgraded to the high luminosity LHC.Increasing the luminosity makes muon triggering reliable and offline reconstruction very challenging.To enhance the redundancy of the Compact Muon Solenoid(CMS)Muon system and resolve the ambiguity of track reconstruction in the forward region,an improved Resistive Plate Chamber(iRPC)with excellent time resolution will be installed in the Phase-2 CMS upgrade.The iRPC will be equipped with Front-End Electronics(FEE),which can perform high-precision time measurements of signals from both ends of the strip.New Back-End Electronics(BEE)need to be researched and developed to provide sophisticated functionalities such as interacting with FEE with shared links for fast,slow control(SC)and data,in addition to trigger primitives(TPs)generation and data acquisition(DAQ).Method The BEE prototype uses a homemade hardware board compatible with the MTCA standard,the back-end board(BEB).BEE interacts with FEE via a bidirectional 4.8 Gbps optical paired-link that integrates clock,data,and control information.The clock and fast/slow control commands are distributed from BEB to the FEE via the downlink.The uplink is used for BEB to receive the time information of the iRPC’sfired strips and the responses to the fast/slow control commands.To have a pipelined detector data for clusterfinding operation,recover(DeMux)the time relationship of which is changed due to the transmission protocol for the continuous incoming MUXed data from FEE.Then at each bunch crossing(BX),clusteringfired strips that satisfy time and spatial constraints to generate TPs.Both incoming raw MUXed detector data and TPs in a time window and latency based on the trigger signal are read out to the DAQ system.Gigabit Ethernet(GbE)of SiTCP and commercial 10-GbE are used as link standards for SC and DAQ,respectively,for the BEB to interact with the server.Results The joint test results of the BEB with iRPC and Front-End Board(FEB)show a Bit Error Rate of the transmission links less than 1×10-16,a time resolution of the FEB Time-to-Digital Converter of 16 ps,and the resolution of the time difference between both ends of 160 ps which corresponding a spatial resolution of the iRPC of approximately 1.5 cm.Conclusion Test results showed the correctness and stable running of the BEB prototype,of which the functionalities fulfill the iRPC requirements.展开更多
基金the National Research Foundation of Korea(Nos.2018R1A5A7023490 and 2022R1A2C1003003)。
文摘A chemo-mechanical model is developed to investigate the effects on the stress development of the coating of polycrystalline Ni-rich LiNixMnyCo_(z)O_(2)(x≥0.8)(NMC)particles with poly(3,4-ethylenedioxythiophene)(PEDOT).The simulation results show that the coating of primary NMC particles significantly reduces the stress generation by efficiently accommodating the volume change associated with the lithium diffusion,and the coating layer plays roles both as a cushion against the volume change and a channel for the lithium transport,promoting the lithium distribution across the secondary particles more homogeneously.Besides,the lower stiffness,higher ionic conductivity,and larger thickness of the coating layer improve the stress mitigation.This paper provides a mathematical framework for calculating the chemo-mechanical responses of anisotropic electrode materials and fundamental insights into how the coating of NMC active particles mitigates stress levels.
文摘Interpretation of quantitative results of nerve fiber layer (NFL) thickness based on scanning laser polarimetry (GDx-NFA) can be quite challenging especially in glaucoma suspects. Purpose: Authors studied NFL parameters obtained from GDx-NFA in glaucoma suspects and compared them with those of patients with glaucoma Methods: Eighty six glaucoma suspects based
文摘Frequency doubling perimetry (FDP) may idendtify glaucoma at a relatively early stage even before conventional perimetry does. Scanning laser polarimetry (GDx) has shown to differentiate nerve fiber layer thickness (NFLT) between glaucomatous
基金supported by the National Natural Science Foundation of China(No.12035018)the IHEP Innovation Fund(Y9545150U2)the National Key Programme for S&T Research and Development(Grant No.:2016YFA0400104).
文摘Purpose The Large Hadron Collider(LHC)at European Organization for Nuclear Research is planned to be upgraded to the high luminosity LHC.Increasing the luminosity makes muon triggering reliable and offline reconstruction very challenging.To enhance the redundancy of the Compact Muon Solenoid(CMS)Muon system and resolve the ambiguity of track reconstruction in the forward region,an improved Resistive Plate Chamber(iRPC)with excellent time resolution will be installed in the Phase-2 CMS upgrade.The iRPC will be equipped with Front-End Electronics(FEE),which can perform high-precision time measurements of signals from both ends of the strip.New Back-End Electronics(BEE)need to be researched and developed to provide sophisticated functionalities such as interacting with FEE with shared links for fast,slow control(SC)and data,in addition to trigger primitives(TPs)generation and data acquisition(DAQ).Method The BEE prototype uses a homemade hardware board compatible with the MTCA standard,the back-end board(BEB).BEE interacts with FEE via a bidirectional 4.8 Gbps optical paired-link that integrates clock,data,and control information.The clock and fast/slow control commands are distributed from BEB to the FEE via the downlink.The uplink is used for BEB to receive the time information of the iRPC’sfired strips and the responses to the fast/slow control commands.To have a pipelined detector data for clusterfinding operation,recover(DeMux)the time relationship of which is changed due to the transmission protocol for the continuous incoming MUXed data from FEE.Then at each bunch crossing(BX),clusteringfired strips that satisfy time and spatial constraints to generate TPs.Both incoming raw MUXed detector data and TPs in a time window and latency based on the trigger signal are read out to the DAQ system.Gigabit Ethernet(GbE)of SiTCP and commercial 10-GbE are used as link standards for SC and DAQ,respectively,for the BEB to interact with the server.Results The joint test results of the BEB with iRPC and Front-End Board(FEB)show a Bit Error Rate of the transmission links less than 1×10-16,a time resolution of the FEB Time-to-Digital Converter of 16 ps,and the resolution of the time difference between both ends of 160 ps which corresponding a spatial resolution of the iRPC of approximately 1.5 cm.Conclusion Test results showed the correctness and stable running of the BEB prototype,of which the functionalities fulfill the iRPC requirements.