期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
AN ANALYTICAL CALCULATION FOR THE LASER GAIN IN A LONG PULSE FREE-ELECTRON LASER
1
作者 jia qika 《Chinese Physics Letters》 SCIE CAS CSCD 1989年第12期533-536,共4页
For a long pulse free-electron laser(FEL)in the low gain regime,an approximate expression is given to describe the optical field gain from the small signal to the weak saturation.The result is shown to agree with thos... For a long pulse free-electron laser(FEL)in the low gain regime,an approximate expression is given to describe the optical field gain from the small signal to the weak saturation.The result is shown to agree with those from a 1-D computer simulation. 展开更多
关键词 GAIN LASER simulation.
下载PDF
合肥红外自由电子激光装置 被引量:10
2
作者 李和廷 何志刚 +20 位作者 吴芳芳 唐雷雷 赵周宇 张通 何天龙 宣科 张海燕 尉伟 卢平 周泽然 尚雷 刘功发 徐宏亮 何晓业 蒋诗平 裴香涛 高琛 贾启卡 鲍骏 张善才 王琳 《中国激光》 EI CAS CSCD 北大核心 2021年第17期1-9,共9页
合肥红外自由电子激光装置是一台专用于能源化学研究的用户装置,利用一个最高电子能量为60 MeV的S波段直线加速器驱动中红外和远红外两个自由电子激光振荡器,分别产生波长范围为2.5~50μm和40~200μm的红外激光。两个振荡器产生的激光... 合肥红外自由电子激光装置是一台专用于能源化学研究的用户装置,利用一个最高电子能量为60 MeV的S波段直线加速器驱动中红外和远红外两个自由电子激光振荡器,分别产生波长范围为2.5~50μm和40~200μm的红外激光。两个振荡器产生的激光经同一条光束线被传输至实验大厅内的五个实验站。中红外振荡器于2019年调试出光,并于2020年11月达到任务指标。介绍了合肥红外振荡器的自由电子激光装置及其调试进展,重点介绍了中红外振荡器辐射的激光性能。 展开更多
关键词 激光技术 自由电子激光 红外波段 振荡器
原文传递
Design and cold test of S-BAND cavity BPM for HLS 被引量:1
3
作者 LUO Qing SUN BaoGen +2 位作者 jia qika HE DuoHui FANG jia 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2011年第S2期292-295,共4页
An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups ... An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm. 展开更多
关键词 CAVITY BPM RE-ENTRANT cut-through waveguide cold test wire scanning resolution CROSS-TALK
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部