An organically modified silicate(ORMOSIL) based optical sensor response to gaseous O2 or O2 dissolved in water is presented. The oxygen sensing film mechanism is based on the principle of fluorescence quenching of tri...An organically modified silicate(ORMOSIL) based optical sensor response to gaseous O2 or O2 dissolved in water is presented. The oxygen sensing film mechanism is based on the principle of fluorescence quenching of tris(4,7-diphenyl-l , 10-phenanthroline) ruthenium ( ) ([Ru(dpp)3]2+), which has been entrapped in a porous ORMOSIL film. In order to establish optimum film-processing parameters, comprehensive investigations, including the effects of the polarity and the hydrophobicity of the sensing film on oxygen quenching response and response time, were carried out. The film hydrophobicity increased as a function of dimethyl-dimethoxysilane (DiMe-DMOS) content, which is correlated with enhanced oxygen sensor performance. The sensor developed in the present work exhibits the advantages of fast response time and good reversibility. The detection limits are 0. 5 % and 0. 3 g/mL for O2 in the gaseous and the aqueous phases, respectively.展开更多
目的:对睡眠担忧量表(Anxiety and Preoccupation about Sleep Questionnaire, APSQ)进行翻译,并检验其信度和效度。方法:对650名倒班护士进行APSQ中文版施测。采用匹兹堡睡眠质量指数问卷、Epworth嗜睡量表、抑郁症状筛查量表、Chalde...目的:对睡眠担忧量表(Anxiety and Preoccupation about Sleep Questionnaire, APSQ)进行翻译,并检验其信度和效度。方法:对650名倒班护士进行APSQ中文版施测。采用匹兹堡睡眠质量指数问卷、Epworth嗜睡量表、抑郁症状筛查量表、Chalder疲劳量表和压力感知量表检验效标关联效度。间隔4周后,随机选取65名护士进行APSQ重测,以检验其重测信度。结果:探索性因素分析和验证性因素分析的结果支持APSQ的单因子模型。APSQ的内部一致性系数、分半信度和重测信度分别为0.88、0.92和0.73。APSQ与睡眠问题、嗜睡、抑郁、疲乏感和压力感知存在显著的正相关(0.41~0.62)。结论:中文版睡眠担忧量表的信效度符合心理测量学标准,可应用于倒班护士睡眠障碍的相关研究。展开更多
基金NSFC(No.4001161946)and CRGC joint research project.
文摘An organically modified silicate(ORMOSIL) based optical sensor response to gaseous O2 or O2 dissolved in water is presented. The oxygen sensing film mechanism is based on the principle of fluorescence quenching of tris(4,7-diphenyl-l , 10-phenanthroline) ruthenium ( ) ([Ru(dpp)3]2+), which has been entrapped in a porous ORMOSIL film. In order to establish optimum film-processing parameters, comprehensive investigations, including the effects of the polarity and the hydrophobicity of the sensing film on oxygen quenching response and response time, were carried out. The film hydrophobicity increased as a function of dimethyl-dimethoxysilane (DiMe-DMOS) content, which is correlated with enhanced oxygen sensor performance. The sensor developed in the present work exhibits the advantages of fast response time and good reversibility. The detection limits are 0. 5 % and 0. 3 g/mL for O2 in the gaseous and the aqueous phases, respectively.
文摘目的:对睡眠担忧量表(Anxiety and Preoccupation about Sleep Questionnaire, APSQ)进行翻译,并检验其信度和效度。方法:对650名倒班护士进行APSQ中文版施测。采用匹兹堡睡眠质量指数问卷、Epworth嗜睡量表、抑郁症状筛查量表、Chalder疲劳量表和压力感知量表检验效标关联效度。间隔4周后,随机选取65名护士进行APSQ重测,以检验其重测信度。结果:探索性因素分析和验证性因素分析的结果支持APSQ的单因子模型。APSQ的内部一致性系数、分半信度和重测信度分别为0.88、0.92和0.73。APSQ与睡眠问题、嗜睡、抑郁、疲乏感和压力感知存在显著的正相关(0.41~0.62)。结论:中文版睡眠担忧量表的信效度符合心理测量学标准,可应用于倒班护士睡眠障碍的相关研究。