Characteristics of NO reduction with non-thermal plasma 被引量:7
1
作者 YUGang YUQi +1 位作者 jiangyan-long ZENGKe-si 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第4期627-630,共4页
As a new type of NO removal system, NO reduction in N_2-NO plasma was applied to solve the difficulties in the traditional methods, such as higher energy-consumption, larger equipment size and high cost, and so on. Us... As a new type of NO removal system, NO reduction in N_2-NO plasma was applied to solve the difficulties in the traditional methods, such as higher energy-consumption, larger equipment size and high cost, and so on. Using the experimental NO reduction system with single-pair electrode tip discharge structure, the NO reduction characteristics of N_2-NO system were revealed to guide the engineering practice; the results of NO reduction with single-pair electrode tip discharge plasma also have the same instructive meaning to the NO reduction with multi-pair electrode tip discharge plasma. The amount of both active N atom and NO removal rate increased with the distance l_g increasing between the two electrode tips and then dropped when the distance exceeded a certain value. The NO removal rate increased while the voltage between two electrode tips or the resident time of gas flow increased. The distance is a key geometrical variable factor that can determine the intensity of electric field between two electrode tips and the resident time of gas. In this paper, the effects of the dielectric features on NO reduction using dielectric-barrier discharge plasma system were also studied. The results of NO removal rate with different dielectrics such as Al_2O_3, CaO, MgO and glass showed that the electric field intensity is different with different dielectric, because it brings different energy to particles in discharge room and thus it causes different NO removal rate. 展开更多
关键词 NO reduction PLASMA CHARACTERISTIC single-pair electrode tip discharge dielectric-barrier discharge
下载PDF
Mechanism of NO reduction with non-thermal plasma 被引量:2
2
作者 YUGang YUQi +2 位作者 jiangyan-long ZENGKe-si GUFan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第3期445-447,共3页
Non-thermal plasma has been proved to be an effective and competitive technology for removing NO in flue gas since 1970. In this paper, the NO reduction mechanism of the non-thermal plasma reaction in NO/N_2/O_2 syste... Non-thermal plasma has been proved to be an effective and competitive technology for removing NO in flue gas since 1970. In this paper, the NO reduction mechanism of the non-thermal plasma reaction in NO/N_2/O_2 system was investigated using the method of spectral analysis and quantum chemistry. By the establishment of NO reduction and gas discharge plasma emission spectrum measuring system, the NO reduction results, gas discharge emission spectra of NO/N_2/O_2 and pure N_2 were obtained, and then the model of molecular orbit of N_2 either in ground state or its excited state was worked out using the method of molecular orbit Ab initio in Self-Consistent Field(SCF). It was found that NO reduction in NO/N_2 gas discharge plasma was achieved mainly through a series of fast elementary reactions and the N(E6) at excited state was the base for NO reduction. 展开更多
关键词 NO reduction PLASMA MECHANISM spectral analysis quantum chemistry
下载PDF
DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER
3
作者 jiangyan-long CHENGuo-bang THUMMESGuenter 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第4期277-280,共4页
An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of t... An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively. 展开更多
关键词 DC流 抑制方法 脉冲冷却管 优化设计
下载PDF