Cost-Effective Monitoring of the Fuel Air Equivalence-Ratio with a Lambda Sensor and a Microcontroller in a Downdraft Biomass Gasifier
1
作者 jean fidele nzihou Salou Hamidou +2 位作者 Ousmane Zoundi Frederic Ouattara Bila Gerard Segda 《Open Journal of Applied Sciences》 2024年第2期545-560,共16页
The operation of biomass treatment devices such as gasifiers is based on the control of key parameters that play an important role in product formation. These include: temperature, excess oxygen, relative humidity and... The operation of biomass treatment devices such as gasifiers is based on the control of key parameters that play an important role in product formation. These include: temperature, excess oxygen, relative humidity and biomass composition. This work focuses on excess oxygen and temperature. Unfortunately, flue gas oxygen analyzers are expensive and not accessible to small industries. However, the equivalence ratio is linked to excess oxygen and has the advantage of not depending on biomass composition. This study therefore focuses on the design and development of a device for controlling this equivalence ratio by measuring oxygen concentration using a self-propelled Lambda probe, and a system for monitoring this equivalence ratio using an Arduino Uno 3 microcontroller. The temperature is recorded with an accuracy of ±1.5°C. For a heating time of 10 minutes, the response time to temperature change is around 3 seconds, which is sufficient for the device to function properly. This simple device is an efficient and cost-effective means of checking the equivalence ratio. 展开更多
关键词 Equivalence Ratio Biomass GASIFICATION Lambda Sensor MICROCONTROLLER C++