期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Effect of Multiple Coatings of One-step Self-etching Adhesive on Microtensile Bond Strength to Primary Dentin 被引量:5
1
作者 Lin Ma Jian-feng Zhou +3 位作者 Jian-guo Tan Quan Jing ji-zhi zhao Kuo Wan 《Chinese Medical Sciences Journal》 CAS CSCD 2011年第3期146-151,共6页
Objective To investigate the effect of multiple coatings of the one-step self-etching adhesive on immediate microtensile bond strength to primary dentin.Methods Twelve caries-free human primary molars were randomly di... Objective To investigate the effect of multiple coatings of the one-step self-etching adhesive on immediate microtensile bond strength to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 groups with 6 teeth each.In group 1,each tooth was hemisected into two halves.One half was assigned to control subgroup 1,which was bonded with a single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 1 in which the adhesive was applied three times before light curing.In group 2,the teeth were also hemisected into two halves.One half was assigned to control subgroup 2,which was bonded with the single-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 2 in which three layers of adhesive were applied with light curing each successive layer.Microtensile bond strength was immediately tested after specimen preparation.Results When the adhesive was applied three times before light curing,the bond strength of the experimental subgroup 1(n=33,57.49±11.61 MPa) was higher than that of the control subgroup 1(n=31,49.71±11.43 MPa,P<0.05).When using the technique of applying multiple layers of adhesive with light curing each successive layer,no difference of immediate bond strength was observed between the control subgroup 2 and the experimental subgroup 2(P>0.05).Conclusion Multiple coatings of one-step self-etching adhesive can increase the immediate bond strength to primary dentin when using the technique of light-curing after applying three layers of adhesive. 展开更多
关键词 拉伸强度 胶粘剂 牙本质 酸蚀 涂料 小学 光固化技术 粘结强度
下载PDF
Efficacy of Topical Tacrolimus for Erosive Oral Lichen Planus: A Meta-analysis 被引量:1
2
作者 Chun-lan Gu ji-zhi zhao +1 位作者 Jie Zhang Hai-tao Dong 《Chinese Medical Sciences Journal》 CAS CSCD 2015年第4期210-217,共8页
Objective To assess the efficacy and safety of topical tacrolimus for erosive oral lichen planus(EOLP). Methods Literatures published up to December 2013 were searched from Pub Med, Embase, CENTRAL, Chinese Bio Medica... Objective To assess the efficacy and safety of topical tacrolimus for erosive oral lichen planus(EOLP). Methods Literatures published up to December 2013 were searched from Pub Med, Embase, CENTRAL, Chinese Bio Medical Literature Database(CBM), and System for Information on Grey Literature in Europe(SIGLE). All randomized controlled trials(RCTs) of topical tacrolimus for EOLP which compared with other interventions or a placebo were considered in this Meta-analysis. Two researchers collected data independently. The assessment of methodological quality was based on Cochrane Handbook and the materials were analyzed with the software Revman 5.2.5. The primary outcome measures were the symptoms(e.g. pain, discomfort) complained by patients. The secondary outcome measures included the improvement rate of clinical signs assessed by the investigators and the incidence of adverse effects(e.g. clinical candidiasis). Results A total of 9 RCTs involving 476 patients were finally included. The pooled odds ratio(OR) of clinical improvement for topical tacrolimus vs. topical corticosteroids was 1.19 [95% confidence interval(CI): 0.64-2.22, I2: 44%]. Regarding to 0.1% tacrolimus and 0.03% tacrolimus, the pooled OR were 1.87(95 % CI: 0.60-5.82) and 1.47(95 % CI: 0.14-16.04) respectively in subgroup analysis. No serious adverse events were reported in topical tacrolimus group. Conclusions There was no evidence to support that topical tacrolimus for EOLP was more effective and safer than topical corticosteroids in this Meta-analysis. Clinical assessment criteria should be established and accepted by clinicians and researchers before further RCTs are undertaken. 展开更多
关键词 TACROLIMUS CORTICOSTEROIDS ORAL LICHEN planus META-ANALYSIS
下载PDF
Multiple Coatings can Improve the Bond Durability of One-step Self-etching Adhesive to Primary Dentin
3
作者 Lin Ma Jian-feng Zhou +2 位作者 Quan Jing ji-zhi zhao Kuo Wan 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第2期106-111,共6页
Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 group... Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 groups.In group 1,each tooth was hemisected into 2 halves.One half was assigned to the control subgroup 1,which was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 1,in which the adhesive was applied three times before light curing.In group 2,one split half tooth was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions;for the other half,three layers of adhesive were applied with each successive layer of light curing.Specimens were stored in 0.9% NaCl containing 0.02% sodium azide at 37℃ for 18 months and then were subjected to microtensile bond strength test and the fracture mode analysis.Results When the adhesive was applied three times before light curing,the bond strength of the experimental subgroup 1 was significantly higher than that of the control subgroup 1(47.46±13.91 vs.38.12±11.21 MPa,P<0.05).When using the technique of applying multiple layers of adhesive with each successive layer of light curing,no difference was observed in bond strength between the control subgroup and the experimental subgroup(39.40±8.87 vs.40.87±9.33 MPa,P>0.05).Conclusion Multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin when using the technique of light-curing after applying 3 layers of adhesive. 展开更多
关键词 耐久性 牙本质 酸蚀 粘接 债券 涂料 光固化胶粘剂 原发性
下载PDF
rypes of Organ Involvement in Patients with Immunoglobulin G4-related Disease 被引量:4
4
作者 Yu Chen ji-zhi zhao +6 位作者 Rui-E Feng Ju-Hong Shi Xue-Mei Li Yun-Yun Fei Yang Shi Wen Zhang Feng-Chun Zhang 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1525-1532,共8页
Background: lmmunoglobulin G4-related disease (IgG4-RD) is a newly recognized systemic disease that can involve multiple organs and various clinical phenotypes. The purpose of this study was to analyze different ty... Background: lmmunoglobulin G4-related disease (IgG4-RD) is a newly recognized systemic disease that can involve multiple organs and various clinical phenotypes. The purpose of this study was to analyze different types of organ involvement in IgG4-RD patients in China. Methods: We conducted a prospective cohort study on IgG4-RD patients to analyze the clinical manifestations and rare features oflgG4-RD. Patients were grouped into different types according to organ involvement regarding organ number and organ site. The constituent ratio in different types was also analyzed. Results: A total of 200 IgG4-RD patients, with a male:female ratio of 2.08:1, were grouped into different types, Cases having involvement of two or three organs were the most common whereas the fewest number of patients had multi-organ (≥4) involvement. Serum IgG4 and lgE levels, IgG4/IgG ratio, and percentage of eosinophils increased as the number of involved organs increased. In addition, constituent ratio analysis revealed that patients with salivary gland/lacrimal gland swelling, who also constituted the largest number of IgG4-RD patients, had higher serum IgG4 concentrations and IgG4/IgG values, had higher percentage of Eos, and were more likely to have had a history of allergies relative to patients with internal organ involvement. Conclusions: The characteristic feature of IgG4-RD is multiple organ involvement with various clinical manifestations and different types. Although serum IgG4 levels increased with the number of involved organs, serum IgG4 levels were higher for those patients with salivary gland/lacrimal gland swelling compared with those with internal organ involvement. Thus, valuable clues to the differential diagnosis of IgG4-RD could be obtained by examining the clinical patterns of organ involvement, 展开更多
关键词 Immunoglobulin G4 lmmunoglobulin G4-related Disease Organ Involvement Prospective Cohort
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部