Comparison of efficacy of two different silicone hydrogel bandage contact lenses after T-PRK
1
作者 Hua Li Ting Shao +3 位作者 jia-fan zhang Lin Leng Sai Liu Ke-Li Long 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第2期299-305,共7页
AIM:To compare the efficacy between two different silicone hydrogel bandage contact lenses after transepithelial photorefractive keratectomy(T-PRK).METHODS:In this randomized controlled trial,a total of 89 patients(17... AIM:To compare the efficacy between two different silicone hydrogel bandage contact lenses after transepithelial photorefractive keratectomy(T-PRK).METHODS:In this randomized controlled trial,a total of 89 patients(178 eyes) who underwent T-PRK at the Qingdao Eye Hospital from October to December 2019 were selected.One random eye wore a Senofilcon A bandage contact lens after surgery,and the other eye a Balafilcon A bandage contact lens.Pain scores,uncorrected visual acuity(UCVA),spherical equivalent(SE),corneal epithelial healing status,epithelial thickness,bandage lenses deposits,lenses movement,and ocular surface conditions were measured and compared.RESULTS:There were no differences between the two groups in UCVA,SE,corneal epithelial healing status,corneal epithelial thickness,tear river heights and tear film rupture time at each follow-up visit.However,postoperative pain scores in the Senofilcon A group were significantly lower than those of the Balafilcon A group(F_(intergroups)=67.833,P<0.001;F_(time)=383.773,P<0.001;F_(interaction)=57.344,P<0.001).The duration of pain in eyes in the Senofilcon A group was shorter than that of the Balafilcon A group(t=-3.326,P=0.001).The surface deposition scores and movement scores of Senofilcon A bandage lenses on the first and fourth days after surgery were lower than those of Balafilcon A bandage lenses(Z=-5.385,-6.782,P<0.001;Z=-8.336,-8.906,P<0.001).CONCLUSION:Both Senofilcon A and Balafilcon A bandage lenses have good efficacy after T-PRK.Senofilcon A lenses are associated with less pain and more comfort compared to Balafilcon A. 展开更多
关键词 transepithelial photorefractive keratectomy bandage contact lenses corneal epithelium PAIN clinical results
下载PDF
Filament geometrical model and nozzle trajectory analysis in the fused deposition modeling process 被引量:1
2
作者 Yu-zhen JIN jia-fan zhang +1 位作者 Ying WANG Zu-chao ZHU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第3期370-376,共7页
The geometrical model of the filament during the fused deposition modeling (FDM) process was firstly proposed based on three different models, tractrix, parabola, and catenary. Comparing with the actual measured filam... The geometrical model of the filament during the fused deposition modeling (FDM) process was firstly proposed based on three different models, tractrix, parabola, and catenary. Comparing with the actual measured filament curves on the Stratasys 1600 FDM machine, it is indicated that the tractrix model had the best agreement with the actual measured curves. With the analytical simulation, the nozzle trajectories in the straight-line deposition road, circle road, and arbitrary continuous curve road were deduced, according to the traxtric based geometrical model of the filament. 展开更多
关键词 Fused deposition modeling (FDM) Filament geometrical model Nozzle trajectory