期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Practical 2.45-GHz microwave-driven Cs-free Hˉ ion source developed at Peking University 被引量:2
1
作者 Tao Zhang Shi-Xiang Peng +8 位作者 wen-Bin Wu Hai-Tao Ren Jing-Feng Zhang jia-mei wen Teng-Hao Ma Yao-Xiang Jiang Jiang Sun Zhi-Yu Guo Jia-Er Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第10期477-483,共7页
A practical 2.45-GHz microwave-driven Cs-free H^- source was improved based on the experimental H^- source at Peking University(PKU). Several structural improvements were implemented to meet the practical requiremen... A practical 2.45-GHz microwave-driven Cs-free H^- source was improved based on the experimental H^- source at Peking University(PKU). Several structural improvements were implemented to meet the practical requirements of Xi'an Proton Application Facility(XiPaf). Firstly, the plasma chamber size was optimized to enhance the plasma intensity and stability. Secondly, the filter magnetic field and electron deflecting magnetic field were enhanced to reduce co-extracted electrons. Thirdly, a new two-electrode extraction system with farther electrode gap and enhanced water cooling ability to diminish spark and sputter during beam extraction was applied. At last, the direct H^- current measuring method was adopted by the arrangement of a new pair of bending magnets before Faraday cup(FC) to remove residual electrons. With these improvements, electron cyclotron resonance(ECR) magnetic field optimization experiments and operation parameter variation experiments were carried out on the H^- ion source and a maximum 8.5-mA pure H^- beam was extracted at 50 kV with the time structure of 100 Hz/0.3 ms. The root-mean-square(RMS) emittance of the beam is 0.25 Π·mm·mrad. This improved H^- source and extraction system were maintenance-free for more than 200 hours in operation. 展开更多
关键词 electron cyclotron resonance (ECR) ion source hydrogen plasma negative ion beam plasma application
下载PDF
A miniaturized 2.45 GHz ECR ion source at Peking University 被引量:1
2
作者 jia-mei wen Shi-Xiang Peng +6 位作者 Hai-Tao Ren Tao Zhang Jing-Feng Zhang wen-Bin Wu Jiang Sun Zhi-Yu Guo Jia-Er Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期374-377,共4页
A miniaturized 2.45 GHz permanent magnet electron cyclotron resonance(PMECR) ion source, which has the ability of producing a tens-m A H+beam, has been built and tested at Peking University(PKU). Its plasma chamb... A miniaturized 2.45 GHz permanent magnet electron cyclotron resonance(PMECR) ion source, which has the ability of producing a tens-m A H+beam, has been built and tested at Peking University(PKU). Its plasma chamber dimension is Φ30 mm×40 mm and the whole size of the ion source is Φ180 mm×130 mm. This source has a unique structure with the whole source body embedded into the extraction system. It can be operated in both continuous wave(CW) mode and pulse mode. In the CW mode, more than 20 m A hydrogen ion beam at 40 k V can be obtained with the microwave power of 180 W and about 1 m A hydrogen ion beam is produced with a microwave power of 10 W. In the pulse mode, more than50 m A hydrogen ion beam with a duty factor of 10% can be extracted when the peak microwave power is 1800 W. 展开更多
关键词 miniaturized ECR ion source hydrogen plasma continuous wave (CW) beam pulse beam
下载PDF
New progress on beam availability and reliability of PKU high intensity CW proton ECR ion source 被引量:1
3
作者 Shi-Xiang Peng Ai-Lin Zhang +6 位作者 Hai-Tao Ren Yuan Xu Tao Zhang Jing-Feng Zhang jia-mei wen Zhi-Yu Guo Jia-Er Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期345-348,共4页
The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high qu... The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high quality 306-hours continuous wave(CW) operating curve at 50 m A@35 ke V has been successfully obtained with a standard compact 2.45 GHz ECR ion source at Peking University(PKU), but the uncertainties that caused beam trips before are unacceptable during an accelerator real operation and should be eliminated. Meanwhile, no permission will be given when the beam power is upgraded from 50 m A@35 ke V to 50 m A@50 ke V. To improve the PKU CW proton source quality, several upgrades were done recently. After those improvements, a new long term CW proton beam experiment at 50 m A@50 ke V was carried out in June 2016. The total running time is 300.5 hours, including near 6 hours ion source preparation and 294 hours non-disturb continuous operation. Within the continuous 13 days operation, no beam-off happened, no spark was observed,no beam drop appeared, no interrupting action was needed, and only a few beam fluctuations caused by the air conditional failure occurred. Beam availability and reliability within the 294 hours is 100%. The root-mean-square(RMS) emittance of this 50 m A@50 ke V CW proton beam is about 0.186 π.mm.mrad. A careful inspection of the ion source was done after this long term operation and no obvious damage was found. The restart experimental results obtained after the ion source inspection prove the high repeatability of PKU PMECRIS. In addition, a 130-m A H+beam was obtained at 50 k V with duty factor of 10%(100 Hz/1 ms) with this source. Details will be presented in this paper. 展开更多
关键词 PKU PMECRIS 50mA@50keV CW proton beam 300-hours continuous operation no beam-off
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部