期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The Determination of Iodide Based on a Flow-injection Coupling Irreversible Biamperometry 被引量:3
1
作者 Li Jun LI Hao CHENG +5 位作者 Wen Yi HUANG Hong Xing KONG jian ling wu jian Ping LU Wei GAO Jun Feng SONG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第12期1629-1632,共4页
A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of perm... A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of permanganate at the platinum electrode to form an irreversible biamperometric detection system. Under the applied potential difference of 0 V, in the 0.05 mol/L sulfuric acid, iodidecan be determined over the range 4.00×10^-7-1.00×10^-5 mol/L with a sampling frequency of 120 samples per hour. The detection limit for I- is 3.0×10^-7 mol/L and the RSD for 40 replicate determinations of 4.0×10^-5 mol/L potassium iodide is 1.68%. The new method was applied to the analysis of iodide in table salt with satisfactory results. 展开更多
关键词 Iodide flow injection irreversible biamperometry gold electrode platinum electrode
下载PDF
Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3
2
作者 Li Jun Li Qi Feng Chen +5 位作者 Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong jian ling wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页
A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum elec... A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. 展开更多
关键词 Flow injection Irreversible biamperometry Chlorogenic acid HONEYSUCKLE
下载PDF
Determination of levodopa in pharmaceutical preparations by irreversible biamperometry 被引量:1
3
作者 Li Jun Li Qi Feng Chen +2 位作者 Hao Cheng Lai Bo Yu jian ling wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第6期703-706,共4页
在铂电极在金电极和高锰酸盐的减小基于 levodopa 的 electrocatalytic 氧化,新奇流动注射不可逆的 biamperometric 方法在在二个电极之间强加的 0 V 的潜在的差别下面为 levodopa 的决心被开发。在 H2SO4 答案,在水流和 levodopa 的... 在铂电极在金电极和高锰酸盐的减小基于 levodopa 的 electrocatalytic 氧化,新奇流动注射不可逆的 biamperometric 方法在在二个电极之间强加的 0 V 的潜在的差别下面为 levodopa 的决心被开发。在 H2SO4 答案,在水流和 levodopa 的集中之间的线性关系与 0.012 mg/L 的察觉限制从 0.04 mg/L 在范围被获得到 20 mg/L。建议方法在药品的准备被用于 levodopa 的决心。 展开更多
关键词 双安培滴定法 左旋多巴 黄金电极 白金电极
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部