期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Gd-EOB-DTPA-enhanced magnetic resonance imaging for focal liver lesions in Chinese patients:a multicenter,open-label,phase Ⅲ study 被引量:36
1
作者 Meng-Su Zeng Hui-Yi Ye +8 位作者 Liang Guo Wei-Jun Peng Jian-Ping Lu Gao-Jun Teng Josy Breuer Yi Huan Ping Li jian-rong xu Chang-Hong Liang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第6期607-616,共10页
BACKGROUND:Contrast agents help to improve visibility in magnetic resonance(MR)imaging.However,owing to the large interstitial spaces of the liver,there is a reduction in the natural contrast gradient between lesions ... BACKGROUND:Contrast agents help to improve visibility in magnetic resonance(MR)imaging.However,owing to the large interstitial spaces of the liver,there is a reduction in the natural contrast gradient between lesions and healthy tissue.This study was undertaken to evaluate the efficacy and safety of the liverspecific MR imaging contrast agent gadoxetate disodium(GdEOB-DTPA)in Chinese patients.METHODS:This was a single-arm,open-label,multicenter study in patients with known or suspected focal liver lesions referred for contrast-enhanced MR imaging.MR imaging was performed in 234 patients before and after a single intravenous bolus of Gd-EOB-DTPA(0.025 mmol/kg body weight).Images were evaluated by clinical study investigators and three independent,blinded radiologists.The primary efficacy endpoint was sensitivity in lesion detection.RESULTS:Gd-EOB-DTPA improved sensitivity in lesion detection by 9.46%compared with pre-contrast imaging for the average of the three blinded readers(94.78%vs 85.32%for Gd-EOB-DTPA vs pre-contrast,respectively).Improvements in detection were more pronounced in lesions less than 1cm.Gd-EOB-DTPA improved diagnostic accuracy in lesion classification.CONCLUSIONS:This open-label study demonstrated that Gd-EOB-DTPA improves diagnostic sensitivity in liver lesions,particularly in those smaller than 1 cm.Gd-EOB-DTPA also significantly improves the diagnostic accuracy in lesion classification,and furthermore,Gd-EOB-DTPA is safe in Chinese patients with liver lesions. 展开更多
关键词 gadoxetate disodium magnetic resonance imaging LIVER focal liver lesions
下载PDF
Optimal b value of diffusion-weighted imaging on a 3.0T magnetic resonance scanner in Crohn's disease 被引量:4
2
作者 Qi Feng Yun-Qi Yan +2 位作者 Jiong Zhu Jin-Lu Tong jian-rong xu 《World Journal of Gastroenterology》 SCIE CAS 2014年第35期12621-12627,共7页
AIM:To determine the optimal b value of diffusionweighted imaging for detecting active inflammation in Crohn's disease.METHODS:Thirty-one patients clinically diagnosed with active Crohn’s disease were referred fo... AIM:To determine the optimal b value of diffusionweighted imaging for detecting active inflammation in Crohn's disease.METHODS:Thirty-one patients clinically diagnosed with active Crohn’s disease were referred for magnetic resonance examination.All patients were scanned on a3.0T magnetic resonance scanner using the same protocol involving four different b values(800,1500,2000and 2500 s/mm2).The diagnostic effect of diffusionweighted imaging was evaluated and compared with endoscopic findings.The diffusion-weighted image quality of four b value groups was evaluated and apparent diffusion coefficient was measured for both nor-mal and inflammatory intestinal segments.RESULTS:The contrast-to-noise ratio and signal-tonoise ratio were not satisfied when b value 2000 or2500 s/mm2 was adopted(36.52±14.95 vs 34.78±24.83,P>0.05;53.58±23.45 vs 47.58±29.67,P>0.05).The qualitative image quality was not enough to meet diagnostic requirement.No matter which b value was chosen,the apparent diffusion coefficient of inflammatory intestinal segments was significantly lower than that of normal intestinal segments(1.38±0.28 vs 2.00±0.38,P<0.01;1.09±0.20 vs 1.50±0.28,P<0.01;0.95±0.19 vs 1.34±0.28,P<0.01;0.88±0.14 vs 1.20±0.21,P<0.01).The lesion detection rate(90.32%),diagnostic sensitivity(81.18%)and specificity(95.10%)would be appropriate when b value 1500 s/mm2 was adopted.CONCLUSION:High b value is suitable for intestinal DW examination on a high field MR scanner. 展开更多
关键词 Crohn’s DISEASE DIFFUSION-WEIGHTED IMAGING b VALUE
下载PDF
Estimation of unloading relaxation depth of Baihetan Arch Dam foundation using long-short term memory network 被引量:1
3
作者 Ming-jie He Hao Li +3 位作者 jian-rong xu Huan-ling Wang Wei-ya xu Shi-zhuang Chen 《Water Science and Engineering》 EI CAS CSCD 2021年第2期149-158,共10页
The unloading relaxation caused by excavation for construction of high arch dams is an important factor influencing the foundation’s integrity and strength.To evaluate the degree of unloading relaxation,the long-shor... The unloading relaxation caused by excavation for construction of high arch dams is an important factor influencing the foundation’s integrity and strength.To evaluate the degree of unloading relaxation,the long-short term memory(LSTM)network was used to estimate the depth of unloading relaxation zones on the left bank foundation of the Baihetan Arch Dam.Principal component analysis indicates that rock charac-teristics,the structural plane,the protection layer,lithology,and time are the main factors.The LSTM network results demonstrate the unloading relaxation characteristics of the left bank,and the relationships with the factors were also analyzed.The structural plane has the most significant influence on the distribution of unloading relaxation zones.Compared with massive basalt,the columnar jointed basalt experiences a more significant unloading relaxation phenomenon with a clear time effect,with the average unloading relaxation period being 50 d.The protection layer can effectively reduce the unloading relaxation depth by approximately 20%. 展开更多
关键词 Columnar jointed basalt Unloading relaxation Long-short term memory(LSTM)network Principal component analysis Stability assessment Baihetan Arch Dam
下载PDF
Differentiation of pyogenic hepatic abscesses from malignant mimickers using multislice-based texture acquired from contrast-enhanced computed tomography 被引量:3
4
作者 Shi-Teng Suo Zhi-Guo Zhuang +5 位作者 Meng-Qiu Cao Li-Jun Qian Xin Wang Run-Lin Gao Yu Fan jian-rong xu 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2016年第4期391-398,共8页
BACKGROUND: Pyogenic hepatic abscess may mimic primary or secondary carcinoma of the liver on contrast-enhanced computed tomography(CECT). The present study was to explore the usefulness of the analysis of multisli... BACKGROUND: Pyogenic hepatic abscess may mimic primary or secondary carcinoma of the liver on contrast-enhanced computed tomography(CECT). The present study was to explore the usefulness of the analysis of multislice-based texture acquired from CECT in the differentiation between pyogenic hepatic abscesses and malignant mimickers.METHODS: This retrospective study included 25 abscesses in 20 patients and 33 tumors in 26 subjects who underwent CECT. To make comparison, we also enrolled 19 patients with hepatic single simple cyst. The images from CECT were analyzed using a Laplacian of Gaussian band-pass filter(5 filter levels with sigma weighting ranging from 1.0 to 2.5). We also quantified the uniformity, entropy, kurtosis and skewness of the multislice-based texture at different sigma weightings. Statistical significance for these parameters was tested with oneway ANOVA followed by Tukey honestly significant difference(HSD) test. Diagnostic performance was evaluated using the receiver operating characteristic(ROC) curve analysis.RESULTS: There were significant differences in entropy and uniformity at all sigma weightings(P〈0.001) among hepatic abscesses, malignant mimickers and simple cysts. The significant difference in kurtosis and skewness was shown at sigma 1.8 and 2.0 weightings(P=0.002-0.006). Tukey HSD testshowed that the abscesses had a significantly higher entropy and lower uniformity compared with malignant mimickers(P=0.000-0.004). Entropy(at a sigma 2.0 weighting) had the largest area under the ROC curve(0.888) in differentiating abscesses from malignant mimickers, with a sensitivity of 81.8% and a specificity of 88.0% when the cutoff value was set to 3.64.CONCLUSION: Multislice-based texture analysis may be useful for differentiating pyogenic hepatic abscesses from malignant mimickers. 展开更多
关键词 texture analysis contrast-enhanced computed tomography liver pyogenic hepatic abscess malignant mimicker
下载PDF
Arachnoid cell involvement in the mechanism of coagulation-initiated inflammation in the subarachnoid space after subarachnoid hemorrhage 被引量:7
5
作者 Zhao-liang XIN Xiao-kang WU +1 位作者 jian-rong xu Xi LI 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2010年第7期516-523,共8页
Objective: To assess if arachnoid cells have the capability to present antigen and activate T-lymphocytes after stimulation by bloody cerebrospinal fluid (CSF), and to illuminate the mechanism of coagulation-initiated... Objective: To assess if arachnoid cells have the capability to present antigen and activate T-lymphocytes after stimulation by bloody cerebrospinal fluid (CSF), and to illuminate the mechanism of coagulation-initiated inflammation in the subarachnoid space after subarachnoid hemorrhage (SAH). Methods: Arachnoid cells were cultured, characterized, and examined by immunofluorescence for the basal expression of human leukocyte antigen-DR (HLA-DR). Expression of HLA-DR, after co-culturing arachnoid cells in vitro with bloody CSF, was investigated by immunofluorescence and flow cytometry (FCM). The variation of arachnoid cells' ultrastructure was observed by transmission electron microscope (TEM). Arachnoid cells were co-cultured with peripheral blood mononuclear cells (PBMCs). The content of soluble interleukin-2 receptor (sIL-2r) in culture medium was detected by enzyme-linked immunosorbent assay (ELISA). Results: (1) Arachnoid cells were successfully cultured for many passages. The immunofluorescent staining was positive for HLA-DR in over 95% of the human arachnoid cells. The punctate HLA-DR was distributed in cytoplasm and not in the karyon. (2) After co-culturing arachnoid cells in vitro with bloody CSF, numerous particles with strong fluorescence appeared in the cytoplasm on Day 6. On Day 8, the quantity of particles and fluorescent intensity were maximal. FCM showed that the percentage of HLA-DR expressing cells was (2.5±0.4)% at the first 5 d, increasing to (60.8±3.6)% on Day 7. (3) After co-culturing arachnoid cells in vitro with bloody CSF, many lysosome and secondary lysosome particles were present in the cytoplasm. Hyperplasia of rough endoplasmic reticulum and enlarged cysts were observed, with numerous phagocytizing vesicles also observed at the edge of the arachnoid cells. (4) Arachnoid cells stimulated by bloody CSF were co-cultured in vitro with PBMCs. The content of sIL-2r in the culture medium, having been maintained at around 1.30 ng/ml during the first 3 d, had increased by Day 4. The content of sIL-2r peaked 7.53 ng/ml on Day 7 and then reduced gradually. Conclusions: (1) Basic HLA-DR expression is present in arachnoid cells. (2) After stimulation by bloody CSF, arachnoid cells have the potential to serve as antigen presenting cells (APCs) and the ability to activate T-lymphocytes, indicating that arachnoid cells are involved in the mechanism of coagulation-initiated inflammation in the subarachnoid space after SAH. 展开更多
关键词 关键词蛛网状的房间 房间文化 人的白血球抗原 -- 医生(HLA 医生) 可溶的 interleukin-2 受体(sIL-2r )
原文传递
Dynamic Compressive Property of Closed-Cell Mg Alloy Composite Foams Reinforced with SiC Particles 被引量:1
6
作者 Wen-Zhan Huang Hong-Jie Luo +2 位作者 Yong-Liang Mu jian-rong xu Ai-Chun Zhao 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2019年第11期1320-1328,共9页
The high-strain-rate mechanical response of Mg alloy/SiC_p composite foams has received increased attention in recent years due to their light weight and potential to absorb large amounts of energy during deformation.... The high-strain-rate mechanical response of Mg alloy/SiC_p composite foams has received increased attention in recent years due to their light weight and potential to absorb large amounts of energy during deformation. Dynamic compressive properties of closed-cell Mg alloy/SiC_p composite foams with diff erent relative densities(0.162, 0.227 and 0.351) and diff erent SiC_p additions(0, 4 and 8 wt%) have been investigated using Split-Hopkinson pressure bar. It is shown that peak stress and energy absorption capacity signifi cantly increase as the relative density increases at the range of testing strain rates. Peak stress and energy absorption display strain rate dependence. The peak stress of specimens with 0 wt% and 4 wt% SiC particles additions grows with increasing strain rate. Meanwhile, the increment in the peak stress of specimens with 8 wt% addition is not signifi cant with strain rate increasing. The increase in strain rate increases the energy absorption capacity. The suitable amount of SiC particles addition has great advantages over increasing the peak stress and energy absorption capacity at the high strain rate. The strain-rate-sensitive matrix, cell morphology, morphological defects and gas pressure have an impact on the strain-rate sensitivity of Mg alloy/SiC_p composite foams. 展开更多
关键词 Mg ALLOY SIC particles Mg alloy/SiC_p COMPOSITE foam Split-Hopkinson pressure bar system(SHPB) DYNAMIC compressive
原文传递
Fin performance of 3-D aerator devices with backward lateral deflectors 被引量:1
7
作者 jian-rong xu Jian-hua Wu +1 位作者 Yu Peng Fei Ma 《Journal of Hydrodynamics》 SCIE EI CSCD 2020年第2期410-413,共4页
In the present work,a 3-D aerator device with backward lateral deflectors,called BLD-3-D aerator device,is developed,and the lateral cavity and fin performance of the BLD-3-D aerator device are experimentally investig... In the present work,a 3-D aerator device with backward lateral deflectors,called BLD-3-D aerator device,is developed,and the lateral cavity and fin performance of the BLD-3-D aerator device are experimentally investigated.The findings show that,the relative lateral cavity length with backward lateral deflectors is shorter than that with current lateral deflectors under the same approach flow conditions,and on the basis of the results of the relative cavity length ratio between the lateral and bottom aerators the BLD-3-D aerator device is of remarkable performance for the water fin control thanks to the decrease of the relative lateral cavity length. 展开更多
关键词 AERATOR backward lateral deflector BLD-3-D aerator device cavity water fin
原文传递
Rationale,design,and baseline characteristics of Chinese registry in early detection and risk stratification of coronary plaques(C-STRAT)study 被引量:1
8
作者 Jun-Jie Yang Dong-Kai Shan +15 位作者 Lei xu Jun-Fu Liang Zhao-Qian Wang Mei Zhang Min Li Wen-Jie Yang jian-rong xu Yong-Gao Zhang Li-Ming Xia Li-Hua Wang Hong-Jie Hu Zhi-Gang Yang Tao Li Qi Tian xu-Dong Lyu Yun-Dai Chen 《Chinese Medical Journal》 SCIE CAS CSCD 2021年第7期870-872,共3页
To the Editor:Coronary computed tomographic angiography(CCTA)has been considered as one of the most important noninvasive imaging modalities in diagnosing coronary artery disease(CAD).[1]Modern scanner of CCTA can pro... To the Editor:Coronary computed tomographic angiography(CCTA)has been considered as one of the most important noninvasive imaging modalities in diagnosing coronary artery disease(CAD).[1]Modern scanner of CCTA can provide precise coronary atherosclerotic plaque information,showing improved diagnostic accuracy and sensitivity for identifying obstructive CAD with a preferable temporal and spatial resolution.Several studies have demonstrated the prognosis value of CCTA for the prediction of future adverse CAD events. 展开更多
关键词 CORONARY RATIONAL SCANNER
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部