期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Ultrasonic positioning system for the calibration of central detector 被引量:1
1
作者 Guo-Lei Zhu jiang-lai liu +2 位作者 Qi Wang Meng-Jiao Xiao Tao Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第1期27-33,共7页
A thorough detector response calibration using radioactive sources is necessary for the Jiangmen Underground Neutrino Observatory. Herein, we discuss the design of a source positioning system based on ultrasonic techn... A thorough detector response calibration using radioactive sources is necessary for the Jiangmen Underground Neutrino Observatory. Herein, we discuss the design of a source positioning system based on ultrasonic technology, aiming for a 3-cm precision over the entire35-m diameter detector sphere. A prototype system is constructed and demonstrated for the experiment. 展开更多
关键词 JUNO CALIBRATION ULTRASONIC POSITIONING
下载PDF
On proportional scintillation in very large liquid xenon detectors 被引量:1
2
作者 Pratibha Juyal Karl-Ludwig Giboni +1 位作者 Xiang-Dong Ji jiang-lai liu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期90-97,共8页
The charge readout of a liquid xenon(LXe)detector via proportional scintillation in the liquid phase was first realized by the Waseda group 40 years ago,but the technical challenges involved were overwhelming.Although... The charge readout of a liquid xenon(LXe)detector via proportional scintillation in the liquid phase was first realized by the Waseda group 40 years ago,but the technical challenges involved were overwhelming.Although the tests were successful,this method was finally discarded and eventually nearly forgotten.Currently,this approach is not considered for large LXe dark matter detectors.Instead,the dual-phase technology was selected despite many limitations and challenges.In two independent studies,two groups from Columbia University and Shanghai Jiao Tong University reevaluated proportional scintillation in the liquid phase.Both studies established the merits for very large LXe detectors,but the Columbia group also encountered apparent limitations,namely the shadowing of the light by the anode wires,and a dependence of the pulse shape on the drift path of the electrons in the anode region.The differences between the two studies,however,are not intrinsic to the technique,but a direct consequence of the chosen geometry.Taking the geometrical differences into account,the results match without ambiguity.They also agree with the original results from the Waseda group. 展开更多
关键词 Liquid detectors Time projection chambers(TPC) Multiplication and electroluminescence in rare gases and liquids
下载PDF
Low-radioactivity ultrasonic hydrophone used in positioning system for Jiangmen Underground Neutrino Observatory
3
作者 Duo Teng jiang-lai liu +6 位作者 Guo-Lei Zhu Yue Meng Yuan-yuan Zhang Tao Zhang Kai Luo Rui Li Jia-Qi Hui 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第6期102-113,共12页
To satisfy the accurate positioning requirement of the calibration source in the Jiangmen Underground Neutrino Observatory, a Tonpilz-type hydrophone with low radioactivity and high electroacoustics is developed.The r... To satisfy the accurate positioning requirement of the calibration source in the Jiangmen Underground Neutrino Observatory, a Tonpilz-type hydrophone with low radioactivity and high electroacoustics is developed.The radioactivity of the proposed hydrophone is strictly controlled by selecting pure raw materials, especially active piezoelectric ceramics. The electroacoustic performance of the hydrophone is improved by making structural optimization. High sensitivity and aimed directivity are achieved using 33-mode piezoelectric ceramic rings arranged in series and improvement in the radiating head of the Tonpilz hydrophone, respectively. All electroacoustic performances are studied through finite element analyses.The simulations indicate that the electroacoustic performances of the hydrophones in linear alkylbenzene-based liquid scintillator can be approximately predicted according to the results in water because their differences caused by two types of acoustic media, water and liquid scintillator, are known. The tests show that the hydrophone prototype can achieve a maximum sensitivity of-209.3dB and a beamwidth of 132.2° at a frequency of 143 kHz.In addition, eight hydrophones only contributed to a background radioactivity level of 26 ± 4 mHz in the neutrino analysis. 展开更多
关键词 JUNO Liquid scintillator Tonpilz hydrophone Low radioactivity Sensitivity DIRECTIVITY Finite element
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部