In-service shear check of heated cased insulated flowlines
1
作者 Zhao Tianfeng Duan Menglan +1 位作者 Jia Xu jiao bintian 《Petroleum Science》 SCIE CAS CSCD 2012年第4期527-531,共5页
Starting friction would be induced and preserved somewhere along the seabed route of cased insulated flowlines(CIF) when the pipe carries service loads.The axial pipe-soil interaction can be divided into three pipe ... Starting friction would be induced and preserved somewhere along the seabed route of cased insulated flowlines(CIF) when the pipe carries service loads.The axial pipe-soil interaction can be divided into three pipe sections:the sliding section,the fixed section and the starting friction section.Although limited to a relatively small length of the pipe,the pipe coats of the starting friction section would suffer much higher shear force caused by thermal expansion than those of the sliding section or the fixed section.Based on the axial equilibrium equation of this kind of insulated pipeline,we developed a method for checking the shear force on CIF coats and their interfaces.The typical example shows that starting friction effect should be taken into account when checking the lap shear strength of heatshrinkable sleeves on CIF field joints. 展开更多
关键词 Cased insulated flowlines starting friction thermal expansion shear failure