期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of spectral domain optical coherence tomography parameters in discriminating preperimetric glaucoma from high myopia 被引量:1
1
作者 Xiao-Yu Xu Hui Xiao +1 位作者 jing-yi luo Xing Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第1期58-65,共8页
AIM: To evaluate the diagnostic ability of macular ganglion cell-inner plexiform layer(GCIPL) thickness o b t a i n e d b y s p e c t r a l-d o m a i n o p t i c a l c o h e r e n c e tomography(SD-OCT) in discriminat... AIM: To evaluate the diagnostic ability of macular ganglion cell-inner plexiform layer(GCIPL) thickness o b t a i n e d b y s p e c t r a l-d o m a i n o p t i c a l c o h e r e n c e tomography(SD-OCT) in discriminating non-highly myopic eyes with preperimetric glaucoma(PPG) from highly myopic healthy eyes. METHODS: A total of 254 eyes, including 76 normal controls(NC), 116 eyes with high myopia(HM) and 62 non-highly myopic eyes with PPG were enrolled. The diagnostic ability of OCT parameters was accessed by the areas under the receiver operating characteristic(AUROC) curve in two distinguishing groups: PPG eyes with nonglaucomatous eyes including NC and HM(Group 1), and PPG eyes with HM eyes(Group 2). Differences in diagnostic performance between GCIPL and RNFL parameters were evaluated. RESULTS: The minimum(AUROC curve of 0.782), inferotemporal(0.758) and inferior(0.705) GCIPL thickness were the top three GCIPL parameters in discriminating PPG from non-glaucomatous eyes, all of which had statistically significant lower diagnostic ability than average RNFL thickness(0.847). In discriminating PPG from HM, the best GCIPL parameter was minimum(0.689), statistically significant lower in diagnostic ability than average RNFL thickness(0.789) and three other RNFL thickness parameters of temporal and inferotemporal clock-hour sectors. CONCLUSION: The minimum GCIPL thickness is the best GCIPL parameter to detect non-highly myopic PPG from highly myopic eyes, whose diagnostic ability is inferiorto that of average RNFL thickness and RNFL thickness of several temporal and inferotemporal clock-hour sectors. The average RNFL thickness is recommended for discriminating PPG from highly myopic healthy eyes in current clinical practice in a Chinese population. 展开更多
关键词 GANGLION cell-inner PLEXIFORM layer DIAGNOSTIC ability preperimetric GLAUCOMA high myopia.
下载PDF
Randomized trial estimating effects of hypnosis versus progressive muscle relaxation on medical students’test anxiety and attentional bias
2
作者 Yang Zhang Xin-Xin Yang +5 位作者 jing-yi luo Meng Liang Ni Li Qian Tao Li-Jun Ma Xiao-Ming Li 《World Journal of Psychiatry》 SCIE 2022年第6期801-813,共13页
BACKGROUND Test anxiety is prevalent among medical students and leads to impaired academic performance.Test-related attentional bias has been identified as an important maintaining factor in test-anxious individuals.A... BACKGROUND Test anxiety is prevalent among medical students and leads to impaired academic performance.Test-related attentional bias has been identified as an important maintaining factor in test-anxious individuals.AIM To evaluate whether hypnosis and progressive muscle relaxation(PMR)could modify medical college students’test anxiety and attentional bias.METHODS A total of 598 medical students were screened.The participants were divided into higher and lower test anxiety groups according to their scores on the test anxiety scale(TAS).Ninety medical college students with high TAS score were randomly assigned to a hypnosis or PMR group.Another 45 students with low TAS score were included,forming a baseline control group.The intervention was conducted weekly for 6 wk,and each session lasted approximately 30 min.The total intervention time and the number of intervention sessions for the hypnosis and PMR groups were equal.Data were collected at the pretest,posttest,and 2-mo follow-up.RESULTS Hypnosis group participants had a significantly lower TAS score at posttest(t=-21.827,P<0.001)and at follow-up(t=-14.824,P<0.001),compared to that at pretest.PMR group participants also had a significantly lower TAS score at posttest(t=-10.777,P<0.001)and at follow-up(t=-7.444,P<0.001),compared to that at pretest.At the posttest level,the hypnosis group had a significantly lower TAS score than the PMR group(t=-3.664,P<0.001).At the follow-up level,the hypnosis group also had a significantly lower TAS score than the PMR group(t=-2.943,P=0.004).Clinically significant improvement was found in both the hypnosis and PMR groups(hypnosis=64.0%;PMR=62.22%).Hypnosis was more effective than PMR in reducing test anxiety among medical college students.Hypnosis could modify attentional bias toward threatening stimuli,but PMR could not.CONCLUSION These results suggest that attentional bias plays an important role in test anxiety treatment. 展开更多
关键词 Test anxiety HYPNOSIS Progressive muscle relaxation Attentional bias Randomized controlled trial
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部