An experiment of a new type full size copper stave for a real blast furnacewas carried out in a special-designed experimental system. The 3-D temperature distribution insidethe stave including isotherm was obtained ba...An experiment of a new type full size copper stave for a real blast furnacewas carried out in a special-designed experimental system. The 3-D temperature distribution insidethe stave including isotherm was obtained based on the experiment data. And the effects of thetemperature of cooling water and the velocity of the water as well as the temperature of the furnaceon the 3-D temperature distribution were obtained. The experimental and calculation results showthat the highest temperature of the hot surface is lower than 90 deg C which is very good for thesolidified slag formation on the hot surface and protecting the stave.展开更多
文摘An experiment of a new type full size copper stave for a real blast furnacewas carried out in a special-designed experimental system. The 3-D temperature distribution insidethe stave including isotherm was obtained based on the experiment data. And the effects of thetemperature of cooling water and the velocity of the water as well as the temperature of the furnaceon the 3-D temperature distribution were obtained. The experimental and calculation results showthat the highest temperature of the hot surface is lower than 90 deg C which is very good for thesolidified slag formation on the hot surface and protecting the stave.