The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and e...The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method.展开更多
The large application of renewable energy generation(REG)has increased the risk of cascading failures in the power system.At the same time REG also provides the possibility of new approaches for the suppression of suc...The large application of renewable energy generation(REG)has increased the risk of cascading failures in the power system.At the same time REG also provides the possibility of new approaches for the suppression of such failures.However,the capacity and position of the synchronous generator(SG)involved in regulation limit the power regu-lation speed(PRS)of REG to the overload line which is the main cause of cascading failures,while the PRS of SG is related to the position and shedding power.REG and SGs have difficulty in achieving effective cooperation under constraints of system power balance.Particularly,the dynamic variation of line flow during power regulation causes new problems for the accurate evaluation of line thermal safety under overload.Therefore,a new strategy for quan-titatively coordinating shedding power and power regulation to block cascading failures in the dynamic security domain is proposed in this paper.The control capability and dynamic security domain of the overload line are mod-eled,and the coordination control method based on power regulation is then proposed to minimize shedding power.The algorithm for the optimal control scheme considers the constraints of load capacity,power source capacity and bus PRS.The correctness of the proposed method is verified using case studies.展开更多
Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threa...Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threat to the safe and stable operation of power systems,and accurate prediction of CF is thus important.However,SCF is affected by the operating characteristics of the main circuit and the coupling effects of sequential control response in the inverter station.These are difficult to predict accurately.In this paper,a new SCF prediction method considering the control response is proposed based on the physical principle of SCF.The time sequence and switching conditions of the controllers at different stages of the first CF recovery process are described,and the corresponding equations of commutation voltage affected by different controllers are derived.The calculation method of the SCF threshold voltage is proposed,and the prediction method is established.Simulations show that the proposed method can predict SCF accurately and provide useful tools to suppress SCF.展开更多
With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equi...With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability.展开更多
文摘The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method.
基金supported in part by the National Natural Science Foundation of China under Grant 51877018in part by the Natural Science Foundation of Chongqing under Grant cstc2019jcyj-msxmX0321in part by the Graduate Research and Innovation Foundation of Chongqing,China under Grant CYB22019.
文摘The large application of renewable energy generation(REG)has increased the risk of cascading failures in the power system.At the same time REG also provides the possibility of new approaches for the suppression of such failures.However,the capacity and position of the synchronous generator(SG)involved in regulation limit the power regu-lation speed(PRS)of REG to the overload line which is the main cause of cascading failures,while the PRS of SG is related to the position and shedding power.REG and SGs have difficulty in achieving effective cooperation under constraints of system power balance.Particularly,the dynamic variation of line flow during power regulation causes new problems for the accurate evaluation of line thermal safety under overload.Therefore,a new strategy for quan-titatively coordinating shedding power and power regulation to block cascading failures in the dynamic security domain is proposed in this paper.The control capability and dynamic security domain of the overload line are mod-eled,and the coordination control method based on power regulation is then proposed to minimize shedding power.The algorithm for the optimal control scheme considers the constraints of load capacity,power source capacity and bus PRS.The correctness of the proposed method is verified using case studies.
基金supported in part by the National Natural Science Foundation of China under Grant(51877018).
文摘Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threat to the safe and stable operation of power systems,and accurate prediction of CF is thus important.However,SCF is affected by the operating characteristics of the main circuit and the coupling effects of sequential control response in the inverter station.These are difficult to predict accurately.In this paper,a new SCF prediction method considering the control response is proposed based on the physical principle of SCF.The time sequence and switching conditions of the controllers at different stages of the first CF recovery process are described,and the corresponding equations of commutation voltage affected by different controllers are derived.The calculation method of the SCF threshold voltage is proposed,and the prediction method is established.Simulations show that the proposed method can predict SCF accurately and provide useful tools to suppress SCF.
基金supported by the National Natural Science Foundation of China(NO.51877018).
文摘With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability.