Based on the performance results of the previously suggested smart building isolation systems (lst companion paper), this following study verifies the control effects of the systems from the view point of energy dis...Based on the performance results of the previously suggested smart building isolation systems (lst companion paper), this following study verifies the control effects of the systems from the view point of energy dissipation and damage level metrics. Several different model cases of the strategically isolated multi-story building structures utilizing passive dampers and semi-active resettable devices are analyzed and the energy-based target indices are compared. Performance comparisons are conducted on statistically calculated story/structural hysteretic energy and story/structural damage demands over realistic suites of earthquake ground motion records, representing seismic excitations of specific return period probability. Again, the semi-active solutions show significant promise for applications ofresettable device, offering advantages over passive systems in the consistent damage reductions. The specific results of this study include the identification of differences in the mechanisms by which smart building isolation systems remove energy, based on the differences in the devices used. Less variability is also seen for the semi-active isolation systems, indicating an increased robustness.展开更多
As a novel structural control strategy, tuned mass damper (TMD) inspired passive and semi-active smart building isolation systems are suggested to reduce structural response and thus mitigate structural damage due t...As a novel structural control strategy, tuned mass damper (TMD) inspired passive and semi-active smart building isolation systems are suggested to reduce structural response and thus mitigate structural damage due to earthquake excitations. The isolated structure's upper stories can be utilized as a large scaled TMD, and the isolation layer, as a core design point, between the separated upper and lower stories entails the insertion of rubber bearings and (i) viscous dampers (passive) or (ii) resettable devices (semi-active). The seismic performance of the suggested isolation systems are investigated for 12-story reinforced concrete moment resisting flames modeled as "10 ~ 2" stories and "8 + 4" stories. Passive viscous damper or semi-active resettable devices are parametrically evaluated through the optimal design principle of a large mass ratio TMD. Statistical performance metrics are presented for 30 earthquake records from the three suites of the SAC project. Based on nonlinear structural models, including P-delta effects and modified Takeda hysteresis, the inelastic time history analyses are conducted to compute the seismic performances across a wide range of seismic hazard intensities. Results show that semi-active smart building isolation systems can effectively manage seismic response for multi-degree-of freedom (MDOF) systems across a broader range of ground motions in comparison to uncontrolled case and passive solution.展开更多
文摘Based on the performance results of the previously suggested smart building isolation systems (lst companion paper), this following study verifies the control effects of the systems from the view point of energy dissipation and damage level metrics. Several different model cases of the strategically isolated multi-story building structures utilizing passive dampers and semi-active resettable devices are analyzed and the energy-based target indices are compared. Performance comparisons are conducted on statistically calculated story/structural hysteretic energy and story/structural damage demands over realistic suites of earthquake ground motion records, representing seismic excitations of specific return period probability. Again, the semi-active solutions show significant promise for applications ofresettable device, offering advantages over passive systems in the consistent damage reductions. The specific results of this study include the identification of differences in the mechanisms by which smart building isolation systems remove energy, based on the differences in the devices used. Less variability is also seen for the semi-active isolation systems, indicating an increased robustness.
文摘As a novel structural control strategy, tuned mass damper (TMD) inspired passive and semi-active smart building isolation systems are suggested to reduce structural response and thus mitigate structural damage due to earthquake excitations. The isolated structure's upper stories can be utilized as a large scaled TMD, and the isolation layer, as a core design point, between the separated upper and lower stories entails the insertion of rubber bearings and (i) viscous dampers (passive) or (ii) resettable devices (semi-active). The seismic performance of the suggested isolation systems are investigated for 12-story reinforced concrete moment resisting flames modeled as "10 ~ 2" stories and "8 + 4" stories. Passive viscous damper or semi-active resettable devices are parametrically evaluated through the optimal design principle of a large mass ratio TMD. Statistical performance metrics are presented for 30 earthquake records from the three suites of the SAC project. Based on nonlinear structural models, including P-delta effects and modified Takeda hysteresis, the inelastic time history analyses are conducted to compute the seismic performances across a wide range of seismic hazard intensities. Results show that semi-active smart building isolation systems can effectively manage seismic response for multi-degree-of freedom (MDOF) systems across a broader range of ground motions in comparison to uncontrolled case and passive solution.