We report a 27-year-old female who presented with abdominal distension, saddle anesthesia, and lower back pain. CT and MRI of the abdomen/spine were performed which showed a large anterior sacral meningocele occupying...We report a 27-year-old female who presented with abdominal distension, saddle anesthesia, and lower back pain. CT and MRI of the abdomen/spine were performed which showed a large anterior sacral meningocele occupying most of the pelvic and abdominal cavity and displacement of their respective contents. Anterior approach was chosen, uterine didelphys was identified and mobilized, meningocele identified and gentle drainage with subsequent resection of the cyst wall and watertight closure was achieved. Subsequent MRI demonstrated resolution of most the sacral meningocele. Patient symptoms improved and are doing well.展开更多
Purpose: Implant subsidence is a possible complication of spinal interbody fusion. We aim to evaluate porous titanium cages subsidence, fusion and functional outcomes in patients subjected to oblique lumbar interbody ...Purpose: Implant subsidence is a possible complication of spinal interbody fusion. We aim to evaluate porous titanium cages subsidence, fusion and functional outcomes in patients subjected to oblique lumbar interbody fusion (OLIF) with these novel devices. Methods: Our institutional review board approved a single-center experience which included 60 patients who underwent OLIF from June 2018 to June 2020 utilizing the porous titanium implants. Data was collected in accordance with the Declaration of Helsinki, and written informed consent was obtained. Imaging studies including radiographs 1, 3, 6 and 12 months and computed tomography (CT) scan at 6 months obtained during routine postoperative follow-up visits, were studied for signs of implant subsidence, fusion and clinical parameters to determine the effectiveness of surgery such as Oswestry disability index (ODI). Results: Radiographic subsidence occurred in 1 out of 89 porous titanium interbody cages (1.1%). No subsidence was observed in the posterior screws and rods fixation group (N = 57). However, one case of subsidence occurred in the lateral plate fixation group (N = 3). The subsidence occurred in an osteoporotic elderly patient operated for adjacent segment disease, and she was later revised with posterior instrumentation using cemented screws and rods. She had an uneventful recovery. Fusion rates were evaluated under CT scan at 6 months with a rate of 88%. In terms of clinical outcomes, ODI decreased significantly from 20.3 preop to 10.7 postop with a P-value Conclusions: In our study, the subsidence rate was lower than previously reported in the literature. Also, we had good fusion rates at 6 months likely due to the porous titanium cages use. We had no subsidence in the posterior instrumented group and one case in the lateral fixation group with improved clinical outcomes.展开更多
文摘We report a 27-year-old female who presented with abdominal distension, saddle anesthesia, and lower back pain. CT and MRI of the abdomen/spine were performed which showed a large anterior sacral meningocele occupying most of the pelvic and abdominal cavity and displacement of their respective contents. Anterior approach was chosen, uterine didelphys was identified and mobilized, meningocele identified and gentle drainage with subsequent resection of the cyst wall and watertight closure was achieved. Subsequent MRI demonstrated resolution of most the sacral meningocele. Patient symptoms improved and are doing well.
文摘Purpose: Implant subsidence is a possible complication of spinal interbody fusion. We aim to evaluate porous titanium cages subsidence, fusion and functional outcomes in patients subjected to oblique lumbar interbody fusion (OLIF) with these novel devices. Methods: Our institutional review board approved a single-center experience which included 60 patients who underwent OLIF from June 2018 to June 2020 utilizing the porous titanium implants. Data was collected in accordance with the Declaration of Helsinki, and written informed consent was obtained. Imaging studies including radiographs 1, 3, 6 and 12 months and computed tomography (CT) scan at 6 months obtained during routine postoperative follow-up visits, were studied for signs of implant subsidence, fusion and clinical parameters to determine the effectiveness of surgery such as Oswestry disability index (ODI). Results: Radiographic subsidence occurred in 1 out of 89 porous titanium interbody cages (1.1%). No subsidence was observed in the posterior screws and rods fixation group (N = 57). However, one case of subsidence occurred in the lateral plate fixation group (N = 3). The subsidence occurred in an osteoporotic elderly patient operated for adjacent segment disease, and she was later revised with posterior instrumentation using cemented screws and rods. She had an uneventful recovery. Fusion rates were evaluated under CT scan at 6 months with a rate of 88%. In terms of clinical outcomes, ODI decreased significantly from 20.3 preop to 10.7 postop with a P-value Conclusions: In our study, the subsidence rate was lower than previously reported in the literature. Also, we had good fusion rates at 6 months likely due to the porous titanium cages use. We had no subsidence in the posterior instrumented group and one case in the lateral fixation group with improved clinical outcomes.