The human body is a heat source in a room. As the human body has a complex shape, it is difficult to accurately measure the airflow distribution around the human body using a conventional anemometer. This study measur...The human body is a heat source in a room. As the human body has a complex shape, it is difficult to accurately measure the airflow distribution around the human body using a conventional anemometer. This study measured the airflow distribution around a thermal manikin acting as a human body by visualization and particle image velocimetry (PIV). The thermal manikin was 1700 mm in height, and its surface temperature was set to 30oC. The experiments were performed in the conditions when the manikin was seated on a chair. The ambient air temperature and wind velocity were experimental variables. The airflow distribution around the manikin was reported by considering the relationships between convection and ambient wind velocity. There were no differences in the airflow distribution around the manikin due to the ambient air temperature when the wind velocity in the chamber was set as 1.0 m/s. Hence, it was assumed that the ambient wind velocity was dominant in this condition. Various airflow distributions were formed around the manikin due to the difference between the body surface temperature and the ambient air temperature in the case where the wind velocity in the chamber was set to approximately equal to 0.0 m/s.展开更多
We review the research and development of beyond Pb/s capacity space-division-multiplexed transmission technology using multi-core optical fibers for satisfying the ever-increasing traffic demand. Moreover, we present...We review the research and development of beyond Pb/s capacity space-division-multiplexed transmission technology using multi-core optical fibers for satisfying the ever-increasing traffic demand. Moreover, we present an optical packet and circuit integrated network technology to improve switching capacity and flexibility in network nodes for the rapid traffic fluctuation and the data service diversification.展开更多
文摘The human body is a heat source in a room. As the human body has a complex shape, it is difficult to accurately measure the airflow distribution around the human body using a conventional anemometer. This study measured the airflow distribution around a thermal manikin acting as a human body by visualization and particle image velocimetry (PIV). The thermal manikin was 1700 mm in height, and its surface temperature was set to 30oC. The experiments were performed in the conditions when the manikin was seated on a chair. The ambient air temperature and wind velocity were experimental variables. The airflow distribution around the manikin was reported by considering the relationships between convection and ambient wind velocity. There were no differences in the airflow distribution around the manikin due to the ambient air temperature when the wind velocity in the chamber was set as 1.0 m/s. Hence, it was assumed that the ambient wind velocity was dominant in this condition. Various airflow distributions were formed around the manikin due to the difference between the body surface temperature and the ambient air temperature in the case where the wind velocity in the chamber was set to approximately equal to 0.0 m/s.
文摘We review the research and development of beyond Pb/s capacity space-division-multiplexed transmission technology using multi-core optical fibers for satisfying the ever-increasing traffic demand. Moreover, we present an optical packet and circuit integrated network technology to improve switching capacity and flexibility in network nodes for the rapid traffic fluctuation and the data service diversification.