期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Investigation of combined degrader for proton facility based on BDSIM/FLUKA Monte Carlo methods 被引量:1
1
作者 Man-Fen Han Jin-Xing Zheng +1 位作者 Xian-Hu Zeng jun-song shen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第2期30-39,共10页
The significant advantage of proton therapy over other particle-based techniques is in the unique physical characteristics of the Bragg peak.It can achieve a highly conformal dose distribution and maximize the probabi... The significant advantage of proton therapy over other particle-based techniques is in the unique physical characteristics of the Bragg peak.It can achieve a highly conformal dose distribution and maximize the probability of tumor control by varying the irradiation energy.Most proton facilities use cyclotrons for fixed energy beam extraction and are equipped with degrader and collimator systems for energy modulation and emittance suppression.However,interactions between charged particles and degrader materials inevitably cause beam loss and divergence and deteriorate beam performance,which present great challenges for downstream transport and clinical treatment.In this work,we investigate a method of energy reduction by combining boron carbide and graphite in a degrader to obtain greater beam transmission at lower energy.The results demonstrate that the beam size and emittance at the exit of the combined degrader diverge less than those of multi-wedge one in the energy range of 70-160 MeV.Correspondingly,the transmission efficiency after the first dipole also shows improvements of 36.26%at 70 MeV and 70.55%at 110 MeV.As a component with a high activity level,the degrader causes additional ambient radiation during operation.Residual induced radiation even remains several hours after system shutdown.Analysis of material activation and induced radiation based on 1 h irradiation with a 400 nA beam current shows that the combined degrader has a definite advantage in shielding despite producing more secondary particles.Both radioactivity and average ambient dose equivalent are reduced by 50%compared with the multiwedge degrader at the important cooling time of 1 h.After 12 h and 24 h of cooling,the radiation levels of degraders decrease slightly due to the presence of long half-life residual nuclides.The average dose generated from the multi-wedge degrader is still 1.25 times higher than that of the combined one. 展开更多
关键词 Proton therapy Degrader Boron carbide Transmission efficiency RADIONUCLIDE Ambient dose equivalent
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部