Effect of viscosity on flow patterns of pumping-up of liquid generated by a cone rotating at the liquid surface has been experimentally studied with various concentrations of glycerol aqueous solution. We have previou...Effect of viscosity on flow patterns of pumping-up of liquid generated by a cone rotating at the liquid surface has been experimentally studied with various concentrations of glycerol aqueous solution. We have previously found that the higher viscous non-Newtonian fluid was lifted-up along the conical surface with a radial filament-wise pattern, which is quite different from the monotonic thin film-wise pattern observed for the lower viscous fluid such as water. In order to elucidate the pumping-up mechanism, a transition diagram indicating the critical rotation rate is obtained as a function of viscosity?of Newtonian fluid in this study, varying from the lower value of water (μ?=?0.890 mPa·s) to the higher one of glycerin (μ?= 910?mPa·s). It is found that there are three categories depending on the viscosity classified as?1) film-wise pumping-up region for the viscosity?μ?≤?134?mPa·s,?2) filament-wise pumping-up one for the viscosity?μ?≥?520?mPa·s, and?3) no pumping-up phenomenon occurs?for 134??μ??mPa·s.展开更多
To reduce the invasiveness of cryosurgery, a miniaturized cryoprobe is necessary. The authors have developed an ultrafine cryoprobe for realizing low-invasive cryosurgery by local freezing. The objectives of this stud...To reduce the invasiveness of cryosurgery, a miniaturized cryoprobe is necessary. The authors have developed an ultrafine cryoprobe for realizing low-invasive cryosurgery by local freezing. The objectives of this study are to estimate the heat transfer coefficient and investigate the characteristics of the phase change heat transfer in the ultrafine cryoprobe. This cryoprobe has a double-tube structure consisting of two stainless steel microtubes. The outer diameter of the cryoprobe was 550 μm. The alternative Freon HFC-23, which has a boiling point of ?82?C at 0.1 MPa, was used as a refrigerant. To evaluate the characteristics of boiling flow in the cryoprobe, the heat transfer coefficient was estimated. The derived heat transfer coefficient was higher than that obtained from the conventional correlation. Additionally, a bubble expansion model was introduced to evaluate the heat transfer mode of the phase change flow in the ultrafine cryoprobe. This model can estimate the liquid film thickness during the expansion of a single bubble in a microchannel. The experimentally measured wall superheat was much lower than that obtained from the model. Therefore, this result also implied that the heat transfer mode in the ultrafine cryoprobe should be nucleate boiling.展开更多
文摘Effect of viscosity on flow patterns of pumping-up of liquid generated by a cone rotating at the liquid surface has been experimentally studied with various concentrations of glycerol aqueous solution. We have previously found that the higher viscous non-Newtonian fluid was lifted-up along the conical surface with a radial filament-wise pattern, which is quite different from the monotonic thin film-wise pattern observed for the lower viscous fluid such as water. In order to elucidate the pumping-up mechanism, a transition diagram indicating the critical rotation rate is obtained as a function of viscosity?of Newtonian fluid in this study, varying from the lower value of water (μ?=?0.890 mPa·s) to the higher one of glycerin (μ?= 910?mPa·s). It is found that there are three categories depending on the viscosity classified as?1) film-wise pumping-up region for the viscosity?μ?≤?134?mPa·s,?2) filament-wise pumping-up one for the viscosity?μ?≥?520?mPa·s, and?3) no pumping-up phenomenon occurs?for 134??μ??mPa·s.
文摘To reduce the invasiveness of cryosurgery, a miniaturized cryoprobe is necessary. The authors have developed an ultrafine cryoprobe for realizing low-invasive cryosurgery by local freezing. The objectives of this study are to estimate the heat transfer coefficient and investigate the characteristics of the phase change heat transfer in the ultrafine cryoprobe. This cryoprobe has a double-tube structure consisting of two stainless steel microtubes. The outer diameter of the cryoprobe was 550 μm. The alternative Freon HFC-23, which has a boiling point of ?82?C at 0.1 MPa, was used as a refrigerant. To evaluate the characteristics of boiling flow in the cryoprobe, the heat transfer coefficient was estimated. The derived heat transfer coefficient was higher than that obtained from the conventional correlation. Additionally, a bubble expansion model was introduced to evaluate the heat transfer mode of the phase change flow in the ultrafine cryoprobe. This model can estimate the liquid film thickness during the expansion of a single bubble in a microchannel. The experimentally measured wall superheat was much lower than that obtained from the model. Therefore, this result also implied that the heat transfer mode in the ultrafine cryoprobe should be nucleate boiling.