Physical Characteristics of Knitted Polyester Vascular Prostheses:Can the Wall Be Considered as a Scaffold for Tissue Regeneration?
1
作者 籍晓萍 王璐 +4 位作者 赵荟菁 姜华 许琭 king martin w GUIDOIN Robert 《Journal of Donghua University(English Edition)》 EI CAS 2010年第1期6-13,共8页
Recent developments in endovascular surgery (EVAR) have opened new avenues to successfully treat aneurysms with percutaneous deployment of stent-grafts.Manufacturers have preferred to use woven fabrics or micro-porous... Recent developments in endovascular surgery (EVAR) have opened new avenues to successfully treat aneurysms with percutaneous deployment of stent-grafts.Manufacturers have preferred to use woven fabrics or micro-porous tubes which are supported by metallic frames or stents.Woven fabrics are much thinner than knits and this permits the use of a smaller delivery catheter.However,since woven constructions are stiffer and have little porosity,the tissue ingrowth is poor or absent.On the other hand,knitted constructions can be considered as a scaffold for tissue ingrowth,and hence they represent an attractive alternative because of their open structure and better conformability in the case of balloon deployment.The present study was undertaken to analyze the properties of two knitted and crimped polyester arterial prototype prostheses,one with and the other without a gelatin coating as sealant.Two commercial controls were also included in the study,namely the uncoated knitted polyester vascular prosthesis VP1200K,and its sealed version,the gelatin coated polyester knitted Gelsoft device,manufactured by Vascutek Ltd.,Scotland,UK.In vitro testing consisted of analyzing the geometry and morphology of the yarn and fabric structures,and measuring the physical and mechanical properties of the grafts,including the water permeability,the longitudinal and radial compliance,and the suture retention strength.In order to compare the different properties of the four samples,tests were also performed on the gelatin coated or sealed devices before and after gelatin removal.The results provided a useful comparison between the prototypes and the commercial control devices.The latter used ten times the amount of gelatin which had been applied as a coating in order to achieve the same low level of impermeability to water.The different amounts of gelatin also explained the different mechanical performance,such as compliance,for these prototype and control prostheses. 展开更多
关键词 动脉的修复术 聚酯 编织 明胶 vitro 机械性质 依从
下载PDF
腔内隔绝术用人造血管移植物(SG)织物覆膜的疲劳性能研究 被引量:1
2
作者 赵荟菁 王璐 +2 位作者 李毓陵 刘肖燕 king martin w 《中国生物医学工程学报》 CAS CSCD 北大核心 2009年第4期637-640,F0004,共5页
对腔内隔绝术用人造血管移植物(stent-graft(SG))的织物覆膜进行动态疲劳性能研究,分析影响其疲劳性能的因素。利用加速疲劳测试仪,对4种覆膜样品进行疲劳性能的测试。实验以覆膜承受的脉动次数为时间点,分别是0次、2.6×107次以及1... 对腔内隔绝术用人造血管移植物(stent-graft(SG))的织物覆膜进行动态疲劳性能研究,分析影响其疲劳性能的因素。利用加速疲劳测试仪,对4种覆膜样品进行疲劳性能的测试。实验以覆膜承受的脉动次数为时间点,分别是0次、2.6×107次以及1×108次(即相当于植入体内0、10个月以及38.5个月)。选择覆膜试样的管径,织物周向和轴向密度以及水渗透性在疲劳试验前后的变化作为疲劳性能的特征指标,这些指标在疲劳试验前后都有不同程度的变化。脉动压力在织物覆膜周向的作用比在轴向的作用要大;织物覆膜在最初阶段疲劳表现明显,而后趋于稳定;组成织物覆膜的纱线越粗,其疲劳表现越明显;复丝织物的疲劳表现比单丝织物更明显。 展开更多
关键词 SG织物覆膜 疲劳性能 纺织结构参数 加速测试 脉动
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部