The SC200 proton therapy superconducting cyclotron was developed by ASIPP (Hefei, China) and JINR (Dubna, Russia). A measurement system was designed to assess the average radial component of the magnetic field (Brav) ...The SC200 proton therapy superconducting cyclotron was developed by ASIPP (Hefei, China) and JINR (Dubna, Russia). A measurement system was designed to assess the average radial component of the magnetic field (Brav) with 15 search coils in the median plane. The winding differences of the search coils affect the measurement accuracy of the Brav. Based on the electromagnetic induction principle, to measure the Brav accurately, this paper focuses on the design and commissioning of the Brav measurement system. The preliminary results confirm that the system design is reasonable and suitable. After testing the search coil at different speeds, the optimal speed was determined as 2.5 mm/s. The relative error was approximately 0.1% under the maximum radial component of the magnetic field Br of 7 G. The measurement precision was up to 1.0×10^-3, which can provide the required measurement tolerance of 3–7 G for Br in the median plane. The commissioning of the Brav measurement system is an important step for Br measurement. It can check and adjust the asymmetry of the superconducting coils (SCs).展开更多
The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A...The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A main radial beam diagnostic system(MRBDS)equipped with a new type of train probe was developed to satisfy the requirements of beam diagnosis.In this paper,the detailed design of the mechanical structure and electronics system of the MRBDS is presented.The electronics system,which includes hardware and software components,was tested and calibrated.The results show that measurement errors can be significantly reduced by the designed calibration procedures.The repeatability of the mechanical structure was also verified,and the experimental results indicate that the unidirectional repeatability of the positioning is better than 0.3 mm.Finally,the MRBDS was used to measure the phase lag of the particles in the beam,and the results showed a high degree of agreement with theoretical calculations,which proved the applicability and high efficiency of the MRBDS.展开更多
基金supported by the Natural Science Foundation of Anhui under Grant(No.1908085QA25)the Research Initiation Foundation of Anhui Polytechnic University(No.2018YQQ001)+3 种基金the PreResearch National Natural Science Foundation of China of Anhui Polytechnic University(No.2019yyzr13)the National Natural Science Foundation of China(Nos.11575237 and 11775258)the National Magnetic Confinement Fusion Science Program(No.2015GB101001)the International Scientific and Technological Cooperation Project of Anhui(No.1704e1002207)
文摘The SC200 proton therapy superconducting cyclotron was developed by ASIPP (Hefei, China) and JINR (Dubna, Russia). A measurement system was designed to assess the average radial component of the magnetic field (Brav) with 15 search coils in the median plane. The winding differences of the search coils affect the measurement accuracy of the Brav. Based on the electromagnetic induction principle, to measure the Brav accurately, this paper focuses on the design and commissioning of the Brav measurement system. The preliminary results confirm that the system design is reasonable and suitable. After testing the search coil at different speeds, the optimal speed was determined as 2.5 mm/s. The relative error was approximately 0.1% under the maximum radial component of the magnetic field Br of 7 G. The measurement precision was up to 1.0×10^-3, which can provide the required measurement tolerance of 3–7 G for Br in the median plane. The commissioning of the Brav measurement system is an important step for Br measurement. It can check and adjust the asymmetry of the superconducting coils (SCs).
基金This work was supported by the funding of the CN-RU cooperation cyclotron design(No.1604b0602005).
文摘The SC200 proton therapy system commissioned by the Hefei CAS Ion Medical and Technical Devices Co.,Ltd.(HFCIM;Hefei,China)and the Joint Institute for Nuclear Research(JINR;Dubna,Russia)has made significant progress.A main radial beam diagnostic system(MRBDS)equipped with a new type of train probe was developed to satisfy the requirements of beam diagnosis.In this paper,the detailed design of the mechanical structure and electronics system of the MRBDS is presented.The electronics system,which includes hardware and software components,was tested and calibrated.The results show that measurement errors can be significantly reduced by the designed calibration procedures.The repeatability of the mechanical structure was also verified,and the experimental results indicate that the unidirectional repeatability of the positioning is better than 0.3 mm.Finally,the MRBDS was used to measure the phase lag of the particles in the beam,and the results showed a high degree of agreement with theoretical calculations,which proved the applicability and high efficiency of the MRBDS.