The electrocaloric effect in thin films of an electrocaloric material has the potential to be used for efficient cooling systems for high power electronic devices. We numerically calculated the effect of parameters in...The electrocaloric effect in thin films of an electrocaloric material has the potential to be used for efficient cooling systems for high power electronic devices. We numerically calculated the effect of parameters in electrocaloric refrigeration with a thermal switch of fluid motion on the thermal performance. The system of changing air and water flow with the pulse generation of cold energy increased the heat transfer efficiency to 67% at a frequency of 5 Hz. The optimum time delay of water flow to increase the heat transfer efficiency was zero at low frequency and became half of the time period to change heat for a high frequency of 100 Hz. When the heat transfer efficiency was high, the final temperature change in water flow was not the maximum temperature change.展开更多
Water consumption can be reduced by using a greenhouse for agriculture in desert areas. We analyzed the effect of control of ventilation, sprinkler water, and solar radiation?shielding on changes of temperature and hu...Water consumption can be reduced by using a greenhouse for agriculture in desert areas. We analyzed the effect of control of ventilation, sprinkler water, and solar radiation?shielding on changes of temperature and humidity in a greenhouse under various desert area conditions. We calculated the changes in temperature and humidity in a greenhouse for a whole day in four seasons, and the calculation results of water consumption with and without a greenhouse were compared. When ventilation, shielding, and sprinkler water were controlled under suitable conditions to grow orchids in a desert area, water consumption in July was only 7% of that without a greenhouse.展开更多
Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient a...Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient and pressure drop of a diamond-shaped fin-array with water flow in this study, which had been reported to have a self-induced flip-flop flow phenomenon. Although the flip-flop flow phenomenon occurred in calculations, it was not observed in experiments. The heat transfer and pressure drop of the diamond-shaped fin-array could be estimated with equations for turbulent flow in tubes.展开更多
文摘The electrocaloric effect in thin films of an electrocaloric material has the potential to be used for efficient cooling systems for high power electronic devices. We numerically calculated the effect of parameters in electrocaloric refrigeration with a thermal switch of fluid motion on the thermal performance. The system of changing air and water flow with the pulse generation of cold energy increased the heat transfer efficiency to 67% at a frequency of 5 Hz. The optimum time delay of water flow to increase the heat transfer efficiency was zero at low frequency and became half of the time period to change heat for a high frequency of 100 Hz. When the heat transfer efficiency was high, the final temperature change in water flow was not the maximum temperature change.
文摘Water consumption can be reduced by using a greenhouse for agriculture in desert areas. We analyzed the effect of control of ventilation, sprinkler water, and solar radiation?shielding on changes of temperature and humidity in a greenhouse under various desert area conditions. We calculated the changes in temperature and humidity in a greenhouse for a whole day in four seasons, and the calculation results of water consumption with and without a greenhouse were compared. When ventilation, shielding, and sprinkler water were controlled under suitable conditions to grow orchids in a desert area, water consumption in July was only 7% of that without a greenhouse.
文摘Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient and pressure drop of a diamond-shaped fin-array with water flow in this study, which had been reported to have a self-induced flip-flop flow phenomenon. Although the flip-flop flow phenomenon occurred in calculations, it was not observed in experiments. The heat transfer and pressure drop of the diamond-shaped fin-array could be estimated with equations for turbulent flow in tubes.