Exergy analysis is a critical aspect of Energy Engineering that can not be overstretched.The need for constant study in this area is very crucial due to it evolving nature.This study involved the analysis of exergy of...Exergy analysis is a critical aspect of Energy Engineering that can not be overstretched.The need for constant study in this area is very crucial due to it evolving nature.This study involved the analysis of exergy of an Experimental Domestic Scale Solar Water Heating System situated in Owerri,Imo State,Nigeria.There were couples of literature reviews done in relation to the study.It was aimed at analyzing the efficiency of solar water heating system.Basic materials involved in this study are solar radiation collector panel,storage tank,pump,heat exchanger,piping unit and heat transfer fluid.From the results,it recorded that collector outlet temperature is a function of solar radiation and time.Maximum Collector Efficiency occurred at 1 p.m.of the set up location time.It was further revealed that performance of the flat plate solar water heater(SWH)obtained maximum of 97%and minimum of 38%efficiencies at 1 p.m.and 5 p.m.respectively.The highest exergy efficiency gotten was 60%at 1 p.m.and the lowest was 1.9%at 9 a.m.Hence,exergy analysis is a useful method for optimizing performance of a flat plate solar water heating system due to it proportionality to basic quantities in solar studies.展开更多
文摘Exergy analysis is a critical aspect of Energy Engineering that can not be overstretched.The need for constant study in this area is very crucial due to it evolving nature.This study involved the analysis of exergy of an Experimental Domestic Scale Solar Water Heating System situated in Owerri,Imo State,Nigeria.There were couples of literature reviews done in relation to the study.It was aimed at analyzing the efficiency of solar water heating system.Basic materials involved in this study are solar radiation collector panel,storage tank,pump,heat exchanger,piping unit and heat transfer fluid.From the results,it recorded that collector outlet temperature is a function of solar radiation and time.Maximum Collector Efficiency occurred at 1 p.m.of the set up location time.It was further revealed that performance of the flat plate solar water heater(SWH)obtained maximum of 97%and minimum of 38%efficiencies at 1 p.m.and 5 p.m.respectively.The highest exergy efficiency gotten was 60%at 1 p.m.and the lowest was 1.9%at 9 a.m.Hence,exergy analysis is a useful method for optimizing performance of a flat plate solar water heating system due to it proportionality to basic quantities in solar studies.