Flow and heat transfer characteristic of supercritical carbon dioxide(SCO_(2))are numerically investigated in the horizontal and vertical tubes.TWL turbulent Prandtl number model could well describe the behavior of SC...Flow and heat transfer characteristic of supercritical carbon dioxide(SCO_(2))are numerically investigated in the horizontal and vertical tubes.TWL turbulent Prandtl number model could well describe the behavior of SCO_(2) affected by the buoyancy.Under the cooling condition,the heat transfer performance of SCO_(2) along the upward direction is best and that along the downward direction is worst when bulk fluid temperatures are below the pseudocritical temperature.Reducing the ratio of heat flux to mass flux could decrease the difference of convective heat transfer coefficient in three flow directions.Under the heating condition,heat transfer deterioration only occurs in vertical upward and horizontal flow directions.Heat transfer deterioration of SCO_(2) could be delayed by increasing the mass flux and the deterioration degree is weakened in the second half of tube along the vertical upward flow direction.Compared with the straight tube,the corrugated tube shows better comprehensive thermal performance.展开更多
In order to study the theoretical cycle characteristic of [mmim]DMP(1-methyl-3-methylimidazolium dimethylphosphate)/methanol absorption refrigeration,the modified UNIFAC group contribution model and the Wilson model a...In order to study the theoretical cycle characteristic of [mmim]DMP(1-methyl-3-methylimidazolium dimethylphosphate)/methanol absorption refrigeration,the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T=280~370K and methanol mole fraction x=0.529~0.965.Thermodynamic performances of absorption refrigeration utilizing [mmim]DMP/methanol,LiBr/H2O and H2O/NH3 are investigated and compared with each other under the same operating conditions.From the results,some conclusions are obtained as follows:1)the circulation ratio of the [mmim]DMP /methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration,but still can be acceptable and tolerable.2)The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration,while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions.3)The[mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.展开更多
With the increase of inlet temperature of gas turbines, the benefits by using the conventional methods are likely to approach their limits. Therefore, it is essential to study novel film cooling methods for surpassing...With the increase of inlet temperature of gas turbines, the benefits by using the conventional methods are likely to approach their limits. Therefore, it is essential to study novel film cooling methods for surpassing these current limits. Based on the theory of heat transfer enhancement, a film cooling method with chemical reaction by cool- ing stream is proposed. In order to test the feasibility of the proposed method, numerical simulations have been conducted. The classic flat plate structure with a 30 degree hole is used for the simulation. In the present study, the effects of the parameters in relation to the chemical reaction on film cooling effectiveness, such as chemical heat sink, volume changes, and reaction rate, are investigated numerically. The conventional film cooling is also calculated for the comparison. The results show that film cooling effectiveness is improved obviously due to the chemical reaction, and the reaction heat and reaction rate of cooling stream have an important effect on film ef- fectiveness. However, the effect of volume changes can be ignored.展开更多
文摘Flow and heat transfer characteristic of supercritical carbon dioxide(SCO_(2))are numerically investigated in the horizontal and vertical tubes.TWL turbulent Prandtl number model could well describe the behavior of SCO_(2) affected by the buoyancy.Under the cooling condition,the heat transfer performance of SCO_(2) along the upward direction is best and that along the downward direction is worst when bulk fluid temperatures are below the pseudocritical temperature.Reducing the ratio of heat flux to mass flux could decrease the difference of convective heat transfer coefficient in three flow directions.Under the heating condition,heat transfer deterioration only occurs in vertical upward and horizontal flow directions.Heat transfer deterioration of SCO_(2) could be delayed by increasing the mass flux and the deterioration degree is weakened in the second half of tube along the vertical upward flow direction.Compared with the straight tube,the corrugated tube shows better comprehensive thermal performance.
基金supported by the National Basic Research Program of China (973 Program) under Grant No.2012CB933200the National Natural Science Fundation of China under Grant No.51276180
文摘In order to study the theoretical cycle characteristic of [mmim]DMP(1-methyl-3-methylimidazolium dimethylphosphate)/methanol absorption refrigeration,the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T=280~370K and methanol mole fraction x=0.529~0.965.Thermodynamic performances of absorption refrigeration utilizing [mmim]DMP/methanol,LiBr/H2O and H2O/NH3 are investigated and compared with each other under the same operating conditions.From the results,some conclusions are obtained as follows:1)the circulation ratio of the [mmim]DMP /methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration,but still can be acceptable and tolerable.2)The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration,while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions.3)The[mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.
基金supported by the National Natural Science Foundation of China (Grant No.50976118)the National Basic Research Program of China (973 Program) Grant No.G2010CB227302
文摘With the increase of inlet temperature of gas turbines, the benefits by using the conventional methods are likely to approach their limits. Therefore, it is essential to study novel film cooling methods for surpassing these current limits. Based on the theory of heat transfer enhancement, a film cooling method with chemical reaction by cool- ing stream is proposed. In order to test the feasibility of the proposed method, numerical simulations have been conducted. The classic flat plate structure with a 30 degree hole is used for the simulation. In the present study, the effects of the parameters in relation to the chemical reaction on film cooling effectiveness, such as chemical heat sink, volume changes, and reaction rate, are investigated numerically. The conventional film cooling is also calculated for the comparison. The results show that film cooling effectiveness is improved obviously due to the chemical reaction, and the reaction heat and reaction rate of cooling stream have an important effect on film ef- fectiveness. However, the effect of volume changes can be ignored.