The main objective of this research is to study the effect of rib arrangement on the distributions of the local heat transfer coefficient in a stationary channel. In this study, the ribs with square cross section were...The main objective of this research is to study the effect of rib arrangement on the distributions of the local heat transfer coefficient in a stationary channel. In this study, the ribs with square cross section were used to place on two side walls for study. The rib height-to-hydraulic diameter ratio (e/Dh) and the rib pitch- to-height (p/e) ratio were fixed at 0.133 and 10, respectively. Three different types of rib arrangement for inclined ribs, V-shaped ribs and inverted V-shaped ribs were investigated. The rib angle of attack (α) was varied from 30° to 90° for inclined ribs and 45° and 60° for both V-shaped and inverted V-shaped ribs, and compared at constant Reynolds number Re =30000. Thermal Liquid Crystal sheet was applied for evaluating the heat transfer distributions. The results showed that the average Nusselt number on surface with rib inclined angle at 60°, 45°, and 60° V-shaped ribs was improved up to about 20%, 25% and 30% higher than case of angle 90° and the rib inclined angle at 60° V-shaped ribs provided the highest Nusselt number covering largest area when compared to the other cases.展开更多
This paper presents the improvement of eco-friendly and power consumption saving refrigerants for refrigeration systems.The novel azeotropic refrigerant mixtures of HFCs and HCs can replace refrigeration systems,and u...This paper presents the improvement of eco-friendly and power consumption saving refrigerants for refrigeration systems.The novel azeotropic refrigerant mixtures of HFCs and HCs can replace refrigeration systems,and using the R134,R32,R125,and R1270 refrigerants in several compositions found using the decision tree function of the RapidMiner software(which camefirst in the KDnuggets annual software poll).All refrigerant results are mixed of POE,which is A1 classification refrigerant,non-flammable,and innocuous refrigerant,and using REFPROP software and CYCLE_D-HX software are under the CAN/ANSI/AHRI540 standards.The boiling point of the new refrigerant mix R-No.595 is 4.58%,lower than that of R404A,with a higher refrigerant effect and 50.34%lower GWP value than R404A.The proposed mix R-No.595 can be operated in hot environmental country and has high critical temperature and heat-rejection effects,due to the presence of R32 and R1270.The COPc of R463A is 13.49%,higher than R404A in freeze condition.The novel refrigerant mixes provide alternate refrig-erant options mixed of 1%R1270,and which are related with the development of current refrigerants,containing a compose of HFOs and eco refrigerants for producing low-GWP,zero ODP,high-refrigerant effect,low-operating pressure,and innocuous refrigerants.展开更多
基金financially supported by the Royal Golden Jubilee Ph.D. program from the Thailand Research Fund (TRF) on contract No. PHD/0061/2557
文摘The main objective of this research is to study the effect of rib arrangement on the distributions of the local heat transfer coefficient in a stationary channel. In this study, the ribs with square cross section were used to place on two side walls for study. The rib height-to-hydraulic diameter ratio (e/Dh) and the rib pitch- to-height (p/e) ratio were fixed at 0.133 and 10, respectively. Three different types of rib arrangement for inclined ribs, V-shaped ribs and inverted V-shaped ribs were investigated. The rib angle of attack (α) was varied from 30° to 90° for inclined ribs and 45° and 60° for both V-shaped and inverted V-shaped ribs, and compared at constant Reynolds number Re =30000. Thermal Liquid Crystal sheet was applied for evaluating the heat transfer distributions. The results showed that the average Nusselt number on surface with rib inclined angle at 60°, 45°, and 60° V-shaped ribs was improved up to about 20%, 25% and 30% higher than case of angle 90° and the rib inclined angle at 60° V-shaped ribs provided the highest Nusselt number covering largest area when compared to the other cases.
基金supported by Prince of Songkla University and SANYO S.M.I.(Thailand)Co.,Ltd.
文摘This paper presents the improvement of eco-friendly and power consumption saving refrigerants for refrigeration systems.The novel azeotropic refrigerant mixtures of HFCs and HCs can replace refrigeration systems,and using the R134,R32,R125,and R1270 refrigerants in several compositions found using the decision tree function of the RapidMiner software(which camefirst in the KDnuggets annual software poll).All refrigerant results are mixed of POE,which is A1 classification refrigerant,non-flammable,and innocuous refrigerant,and using REFPROP software and CYCLE_D-HX software are under the CAN/ANSI/AHRI540 standards.The boiling point of the new refrigerant mix R-No.595 is 4.58%,lower than that of R404A,with a higher refrigerant effect and 50.34%lower GWP value than R404A.The proposed mix R-No.595 can be operated in hot environmental country and has high critical temperature and heat-rejection effects,due to the presence of R32 and R1270.The COPc of R463A is 13.49%,higher than R404A in freeze condition.The novel refrigerant mixes provide alternate refrig-erant options mixed of 1%R1270,and which are related with the development of current refrigerants,containing a compose of HFOs and eco refrigerants for producing low-GWP,zero ODP,high-refrigerant effect,low-operating pressure,and innocuous refrigerants.